• Title/Summary/Keyword: neutral line

Search Result 327, Processing Time 0.027 seconds

Evaluation of the Protection Performance of TT and TN Systems for Low-Voltage Consumers Against Lightning Surges (저압수용가에 공급하는 TT, TN계통의 뇌서지에 대한 보호성능의 평가)

  • Lee, Kyu-Sun;Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.67-74
    • /
    • 2010
  • Most of domestic low-voltage consumers are supplied from the TN-C system of KEPCO, but their load installations have established according to the national statutory standard for electrical installations based on the TT system. In this work, to propose the proper system earthing arrangements of ensuring the protection of information-technology equipment against lightning surges, the protection performance of TT and TN systems against lightning surges was investigated. As a result, when lightning surge was injected to the neutral line of distribution system, the potential difference between the equipment earth terminal and neutral point of low-voltage mains in a TT system was significantly raised. The TT system is not advised due to the risk of damage to the sensitive computer equipment. Main equipotential bonding is an important requirement for protection of low-voltage installations against lightning surges. The TN system provides the best means to reduce the incoming lightning surges through the neutral line of low-voltage service systems. In addition, It is highly recommended to install the additional earthing at the service position of low-voltage consumers.

An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations (분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘)

  • Shin, Dong-Yeol;Kim, Dong-Myung;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.

Investigations of Multi-Carrier Pulse Width Modulation Schemes for Diode Free Neutral Point Clamped Multilevel Inverters

  • Chokkalingam, Bharatiraja;Bhaskar, Mahajan Sagar;Padmanaban, Sanjeevikumar;Ramachandaramurthy, Vigna K.;Iqbal, Atif
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.702-713
    • /
    • 2019
  • Multilevel Inverters (MLIs) are widely used in medium voltage applications due to their various advantages. In addition, there are numerous types of MLIs for such applications. However, the diode-less 3-level (3L) T-type Neutral Point Clamped (NPC) MLI is the most advantageous due to its low conduction losses and high potential efficiency. The power circuit of a 3L T-type NPC is derived by the conventional two level inverter by a slight modification. In order to explore the MLI performance for various Pulse Width Modulation (PWM) schemes, this paper examines the operation of a 3L (five level line to line) T-type NPC MLI for various types of Multi-Carriers Pulse Width Modulation (MCPWM) schemes. These PWM schemes are compared in terms of their voltage profile, total harmonic distortion (THD) and conduction losses. In addition, a 3L T-type NPC MLI is also compared with the conventional NPC in terms of number of switches, clamping diodes, main diodes and capacitors. Moreover, the capacitor-balancing problem is also investigated using the Neutral Point Fluctuation (NPF) method with all of the MCPWM schemes. A 1kW 3L T-type NPC MLI is simulated in MATLAB/Simulink and implemented experimentally and its performance is tested with a 1HP induction motor. The results indicate that the 3L T-type NPC MLI has better performance than conventional NPC MLIs.

Neutral zone and alveolar relation consideration for fabricating complete denture in a patient with severe alveolar bone resorption: a case report (치조제 흡수가 심한 환자에서 중립대 및 치조제 관계를 고려한 총의치 수복 증례)

  • Hyung-Jun Kim;Woo-hyung Jang;Chan Park;Kwi-dug Yun;Hyun-Pil Lim;Sang-Won Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.214-221
    • /
    • 2023
  • In order to fabricate stable dentures in patients with severe resorption of residual ridges, various factors must be considered. One of them is the neutral zone, which is defined as the potential region in which the pressure of the tongue outward in the oral cavity and the pressure of the cheeks and lips directed inward from the outside of the oral cavity equalize during functioning. In patients with severe ridge resorption, if the teeth are usually arranged above the residual ridge, the teeth are located on the lingual side rather than the original position. Therefore, the functional space of the tongue is invaded, the tongue is positioned backward, and the sealing of the lingual border is broken, which acts as a factor reducing the maintenance of denture. In addition, it is also important for the stability of dentures to assume an interalveolar crest line connecting the maxillary and mandibular ridge crests, and to arrange the maxillary and mandibular artificial teeth to match the masticatory force to the interalveolar crest line. Therefore, good clinical results were obtained by fabricating dentures for the patient with poor alveolar residual ridge using neutral zone impression and ridge relationship analysis.

Development of Optical Signal Transmission for the KSTAR Project Pertaining to Instrumentation and Control of the Neutral Beam Test Stand at KAERI

  • Jung, Ki-Sok;Oh, Byung-Hoon
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.3
    • /
    • pp.289-295
    • /
    • 2005
  • Instrumentation and Control (I&C) of the Neutral Beam Test Stand (NB- TS) Facility at the Korea Atomic Energy Research Institute (KAERI) for the Korea Superconducting Tokamak Advanced Research (KSTAR) project has been underway since the start of the project to answer the diverse requests arising from the various facets of the development and construction phases of the project. Optical signal transmission constitutes a significant portion of I&C works and has been performed for the entirety of the project. During the NB- TS construction and related experiments, significant achievements to a more accurate as well as more refined optical signal transmissions have been made. Examples of those I&C works that utilized the optical signal transmission are the Langmuir probe signal transmission, gradient grid current signal transmission, gas flow control and signal transmission, ion source temperature measurement, beam line component temperature monitoring, and coolant flow signal transmission, etc. These optical signal transition provisions are now performing part of the indispensable functions for the proper operation of the NB- TS facility. Attained experience and expertise are expected to be well applied to the upcoming main neutral beam injection (NBI) system construction for the KSTAR project.

A Study on the Cytotoxic Effect of Heavy metals (Cd, Ni, Zn) on Cultured Mouse Fibroblast L929 Cell line (생쥐 배양섬유 모세포주 L929에 미치는 중금속(Cd, Ni, Zn)류의 세포독성에 관한 연구)

  • 이종빈;나명석;황영진;위성욱;최진희;김선희;유춘만;김재민
    • Journal of Environmental Health Sciences
    • /
    • v.23 no.2
    • /
    • pp.98-105
    • /
    • 1997
  • The study on the cytotoxicity of heavy metals was carried out to evaluate the cytotoxic effect of those on mouse L929 fibroblast cell in 96-well microtiter plates. The cytotoxicity was assayed by the neutral red, tetrazolium MTT, total protein, micronuclei test. The cytotoxicity of the heavy metals by neutral red and tetrazolium MTT was showed in order, cadmium > zinc > nickel for the cationic metals tested. The effect of metal-metal interaction on the cytotoxicity showed a marked reduction of cadmium toxicity by zinc, to a lesser degree, by nickel. The amount of total protein in treated group added heavy metals was less than that of the control and treated cadmium alone was less than those of combination with nickel or zinc. At midpoint cytotoxicity values of heavy metals, the frequency of micronuclei on the cell treated heavy metals was more than that of control and treated cadmium alone was more than those of combination with nickel or zinc. From those results, it could be suggested that the heavy metals decreased the viability of mouse fibroblast L929 cells in a concentration-dependent manner and have cytogenic toxic effects, but mixed group decreased the cytotoxic and cytogenic toxicity on L929 cells.

  • PDF

A Study on the Grounding Resistance Effects of Power Transformer in Electric Distribution Systems (배전계통에서 전력용 변압기의 접지저항 영향에 관한 연구)

  • Kim, Kyung-Chul;Jung, Ji-Won;Lee, Kyu-Jin;Lee, Kang-Soo;Choi, Sun-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.113-119
    • /
    • 2010
  • A safe grounding design is used for providing means to carry electric currents into the earth under fault conditions without exceeding any operating limits and for assuring that a person in the vicinity of grounded facilities is not exposed to danger of critical electrical shock. Transformer neutral point grounding is for the purpose of controlling the voltage to earth within tolerable limits under a line-to-ground fault. Transformer frame grounding is for the purpose of minimizing the hazardous potential within safety criteria appearing at the faulted equipment. ills paper deeply investigates the grounding resistance effects of distribution power transformers by analysing the neutral to eatth voltages and touch voltages when the fault occurs.

Parametric Study for Variable Tap of Autotransformer Neutral in AC Feeding (전기철도 단권변압기 중성점 탭절환 특성연구)

  • Han, Moonseob;Lee, Chang-Mu;Kim, Jae-Won;Chang, Sang-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.137-141
    • /
    • 2018
  • The voltage drop is important in electric railway for feeding a huge power of train on fixed feeding area. Nowadays it is tried to operate a high speed trains on conventional lines and there is problem on the voltage drop too. It is simulated on the conditions increased the turn ratio of trolley, installed autotransformer neutral line with variable taps. In result, it is compensated the voltage drop between ATs and better on last AT, not on the position of AT. And it is decreased a return current and neutral current of AT because of unbalance between trolley and feeder. It should be studied faster and more controllable the solid state switchs instead of the mechanical one in order to utilize this system.

An Approach for Construction of Shipyard Simulation Environment based on Neutral File Format (중립파일 기반의 조선소 시뮬레이션 환경에 관한 연구)

  • Woo, Jong Hun;Hwang, Yoon-Suk;Nam, Jong-Ho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.1
    • /
    • pp.18-28
    • /
    • 2016
  • In shipbuilding, the scheduling system is susceptible to sudden changes and thus it turns to be difficult to predict the differences between schedule and production records in advance. A computer-based simulation is commonly utilized to overcome the discrepancies occurred in estimating workloads and resulting processing times. The main drawback of this simulation-based solution is its limited applicability because, in most cases, each shipyard requires specific and customized simulation environment. By standardizing the planning data of the midterm scheduling system, as proposed in this paper, the efficiency of the current simulation model can be enhanced. To present an alternative approach, this paper begins with the analysis of the complex planning data structure of several shipyards and then proceeds to construct a standard data structure based on the neutral format. An interface application is developed for the data transaction and simulation in on-line environment. As a result, a simulation-based production management of shipyards can be achieved by the efficient prediction of planning and scheduling.

A Divece for Reducing the Zero phaze Harmonics of Neutral Line of Power Facility (전기수용설비의 중성선 영상분고조파전류저감장치)

  • Kang, Chang-Won;Choi, Gil-Soo;Han, Sung-Bae;Kim, Bum-Soo;Chung, Yeon-Hae;Lee, Ki-Cheol
    • Electric Engineers Magazine
    • /
    • v.228 no.8
    • /
    • pp.43-48
    • /
    • 2001
  • Wide use of non-linear loads such as personal computers, monitors, laser printers, variable speed drives, UPS systems and other electronic equipment have led to harmonics becoming #1 issue in the electrical industry today. Commercial and Industrial building power distribution systems, designed for the old, linear-style loads especially when found in high densities. Some common power system problems include overloaded neutral conductors, overheated distribution transfOlmers, high neutral-to-ground voltage, poor power factor and distortion of the voltage waveform supplying these loads. The power quality problems, particularly high voltage distortion, have been known to cause equipment downtime due to malfunctions and component failure.

  • PDF