중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발 (Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire)

  • 곽동걸;김진환;이봉섭
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전의 타당성 평가 (Suitability Evaluation on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System)

  • 정석산;이종범;김용갑;송일근;김병숙
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2135-2142
    • /
    • 2010
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as locations and current types of lightning stroke. Overvoltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

高調波 中性電流를 低減시키기 위한 3相4線 竝列形 能動필터에 關한 硏究 (A Novel Three-Phase Four-Wire Shunt Active Filter to Eliminate Neutral Current)

  • 고경수;김래기;유권종;송진수;김시경
    • 전력전자학회논문지
    • /
    • 제3권3호
    • /
    • pp.184-190
    • /
    • 1998
  • 대부분의 빌딩과 공장에서는 3상 4선식 저압 배전 시스템으로 전력을 공급받고 있다. 이 방식은 중성선에 전류가 흐르게 하는데 오늘날 전력 변환 기술의 개발과 컴퓨터의 보급으로 심각한 중성 전류가 발생하고 있다. 본 논문은 병렬형 3상 4선 능동 필터를 사용하여 계통의 전원 전압이 불평형이고 불평형 부하 및 비선형 부하가 접속된 상태에서 전원쪽으로 흐르는 중성 전류를 제거시키고, 전원전류의 파형을 정현파로 개선하는데 목적이 있으며, 부하 조건을 변화시키면서 시뮬레이션을 실행하여 능동 필터의 우수한 성능을 입증하였다.

  • PDF

±500kV HVDC 2회선 송전선로의 전기환경특성 예측 및 평가 (Prediction and Analysis of Electrical Environmental Characteristics under ±500kV HVDC Double Bipole Transmission Line)

  • 우정민;주문노;신구용;권구민;최우정;이재현
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.554-560
    • /
    • 2018
  • Since Korea has a small land area, it is expected to construct the conductor return type with neutral wire in the case of ${\pm}500kV$ HVDC double bipole transmission line. Therefore, in order to apply ${\pm}500kV$ HVDC double bipole transmission line with neutral wire in Korea, it is necessary to develop technology for insulation and environmental designs. In this study, radio interference, audible noise, electric field and ion current density according to the polarity arrangement were compared and assessed in the ${\pm}500kV$ HVDC double bipole transmission line with the conductor return method. And the optimum configuration of HVDC double bipole transmission line was determined from the viewpoint of electrical environment.

굽힘응력을 받는 유연전자소자에서 중립축 위치의 제어 (Control of Position of Neutral Line in Flexible Microelectronic System Under Bending Stress)

  • 서승호;이재학;송준엽;이원준
    • 마이크로전자및패키징학회지
    • /
    • 제23권2호
    • /
    • pp.79-84
    • /
    • 2016
  • 유연전자소자가 외부힘에 의해 변형될 경우 반도체 다이가 기계적 응력 때문에 변형되거나 파괴되고 이러한 변형이나 파괴는 channel의 전자이동도를 변화시키거나 배선의 저항을 증가시켜 집적회로의 동작 오류를 발생시킨다. 따라서 반도체 집적회로는 굽힘 변형이 발생해도 기계적 응력이 발생하지 않는 중립축에 위치하는 것이 바람직하다. 본 연구에서는 굽힘변형을 하는 flip-chip 접합공정이 적용된 face-down flexible packaging system에서 중립축의 위치와 파괴 모드를 조사하였고 반도체 집적회로와 집중응력이 발생한 곳의 응력을 감소시킬 수 있는 방법을 제시하였다. 이를 위해, 설계인자로 유연기판의 두께 및 소재, 반도체 다이의 두께를 고려하였고 설계인자가 중립축의 위치에 미치는 영향을 조사한 결과 유연기판의 두께가 중립축의 위치를 조절하는데 유용한 설계인자임을 알 수 있었다. 3차원 모델을 이용한 유한요소해석 결과 반도체 다이와 유연기판 사이의 Cu bump 접합부에서 항복응력보다 높은 응력이 인가될 수 있음을 확인하였다. 마지막으로 flexible face-down packaging system에서 반도체 다이와 Cu bump 의 응력을 감소시킬 수 있는 설계 방법을 제안하였다.

무절연구간을 위한 열차위치검지방식 검토 (A review of the train position detection method for neutral section with energized condition)

  • 이태훈;이시빈;홍현표;이희순;박기범
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1100-1105
    • /
    • 2010
  • The high speed line and conventional line are a single-phase AC feeding system; and power supplies of different phases meet at SS(SubStation)s or SP(Sectioning Post)s. These sections should be negotiated with the main circuit breaker in the traction vehicle switched off, whereby the length of the neutral zone prevents the pantographs shunting adjacent overhead line section. In order for electric railway vehicles to make power running there, there must be a power supply changeover section (approx. for 1km), where a changeover switch changes a power supply to the other power supply of a train running direction sequentially. For a thorough changeover switching control, the precise train position detection is necessarily required. In this paper, to realize the ground-based train position detection method, configuration scheme of train position detection equipment is suggested by using track circuit and axle counter.

  • PDF

3상 4선식 배선의 중성선에 탈락시 부하 전압 상승 방지를 위한 중성선 보상기에 관한 연구 (A study on the neutral line compensator for prevention of rising at load voltage instantly when disconnect the neutral line in 3phase 4 line system)

  • 김현우;백동현
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 추계학술논문발표회 논문집
    • /
    • pp.522-525
    • /
    • 2011
  • 3상 4선식 배선 라인에서 중성선이 탈락할 경우 부하측의 중선선에 연결된 일부의 부하측 전압은 급상승하게 되고 이로 인한 피해가 많으므로 본 연구에서는 배전라인의 점검시 또는 접촉 불량에 의하여 발생할 수 있는 중성선의 탈락을 순간 감지하고 이를 보상하여 별도로 중성선을 생성하여 새로운 중성선을 순간 제공함으로서 중성선 탈락에 의한 피해를 최대한 억제하고자 하는 것이다. 이로 인하여 부하측의 전압상승에 의한 전기적 재해를 사전에 미리 예방이 가능한 효과도 있게 된다.

  • PDF

집전전압 향상을 위한 가변탭 단권변압기 검토 (Evaluation of the variable TAB Autotransformer for ascending collecting Voltage)

  • 이장무;한문섭;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1426-1430
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing electric load at feeding system, collecting voltage of train and end voltage are going down. So to increase voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

비접지 선박 3상 배전선로의 대지전압 벡터 모니터링 장치의 구성 (Configuration of a Module for Monitoring Voltages Between Power Lines and Hull Onboard Vessels Based on the Vector Diagram at 3 Phase Ungrounded Power Distribution System)

  • 최순만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권8호
    • /
    • pp.1111-1116
    • /
    • 2011
  • 비접지방식 선박에서의 접지 고장은 대지 임피던스의 불평형을 가져오고 대지전압을 상승시켜 감전이나 전기화재의 염려가 높아진다. 접지에 따른 이 같은 대지전압의 왜곡 상태는 전기안전의 측면에서 실시간으로 감시할 필요가 있으며 이 경우 대지전압의 측정치를 위상변화 감시가 가능한 벡터다이어그램으로 나타내는 것이 효과적이다. 대지전압의 상태는 중성점 위치에 의해 표시될 수 있다는 점에서 우선 측정된 대지전압 입력에 대해 벡터 평면의 중성점을 출력하는 연산과정과 알고리즘의 해석이 필요하다. 이를 토대로 본 연구에서는 매 샘플링 주기마다 대지전압을 입력하여 컴퓨터 모니터 상에 중성점과 벡터 대지전압을 출력하는 모듈을 구성한 후 실제 배전선로에서의 실험을 통해 제시한 장치의 적정성을 확인하였다.

단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석 (Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer)

  • 김종겸;김지명
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.