• Title/Summary/Keyword: neutral line

Search Result 327, Processing Time 0.024 seconds

A Study on the Problems of the Neutral Line Due to the 3rd Harmonic (중성선 공용시 3배수 고조파에 따른 문제점 분석)

  • Cho, Nam-Hun;Jung, Jum-Soo;Park, Yong-Woo;Ha, Bok-Nam;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.76-83
    • /
    • 2008
  • The neutral current is made of both the load unbalanced current and the 3rd harmonic. The 3rd harmonic which is the source of the main neutral current is generated from the loads using bridge rectifier circuits on their input produce currents. TV, computer and monitor which are belong to IEC 61000-3-2 Class D are the main 3rd harmonic current sources. In order to show the affect of the distribution system by these disturbances, this paper has studied the current standards of the Korea Electric and considers the problem of the neutral common.

Model Postures at Fashion Shows According to Their Clothing Fashion Images: Focusing on Elegance Image and Neutral-gender Image (패션이미지에 따른 패션쇼 모델의 신체연출에 관한연구 - (제1보) 우아미와 중성미를 중심으로 -)

  • Heo, MIn-Jung;Chung, Sung-Jee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.16 no.2
    • /
    • pp.31-40
    • /
    • 2014
  • The purpose of the study was to examine model postures at fashion shows with respect to expressing fashion images including elegance and neutral-gender images. Data were gathered from the fashion shows held 2000 S/S through 2009 F/W, when elegance and neutral-gender fashion images were obvious in fashion collections. Three designer brands representing elegance and neutral-gender fashion images were selected by the researcher and fashion specialists including graduate students majoring in fashion. The fashion collection photos representing each image were selected from style.com, a website which contains four world's biggest fashion collections. The results showed different hand positions as a model posture according to fashion images. In the neutral-gender image, 16 photos (47%) showed a hand position at pockets, in the elegance image, 24 photos (82.3%) showed a hand position laying down by the sides. Also, walking pose was shown to be different between two fashion images. In the neutral-gender fashion image, 16 photos (52.9%) revealed a pose of 'natural walk', while 29 photos (100%) showed a pose of 'walk in a straight line' in the elegance imaged fashion. In conclusion, the neutral-gender image photos showed the pocket-positioned hand and the 'natural walk' poses more than elegance image photos, and elegance image photos revealed the hand position laying down by the sides and the 'walk in a straight line' poses than the photos of the neutral-gender image.

  • PDF

Estimation of Stellate Ganglion Block Injection Point Using the Cricoid Cartilage as Landmark Through X-ray Review

  • Park, Jeong-Soo;Kim, Ki-Jun;Lee, Youn-Woo;Yoon, Duck-Mi;Yoon, Kyung-Bong;Han, Min-Young;Choi, Jong-Bum
    • The Korean Journal of Pain
    • /
    • v.24 no.3
    • /
    • pp.141-145
    • /
    • 2011
  • Background: Stellate ganglion block is usually performed at the transverse process of C6, because the vertebral artery is located anterior to the transverse process of C7. The purpose of this study is to estimate the location of the transverse process of C6 using the cricoid cartilage in the performance of stellate ganglion block. Methods: We reviewed cervical lateral neutral-flexion-extension views of 48 patients who visited our pain clinic between January and June of 2010. We drew a horizontal line at the surface of the cricoid cartilage in the neutral and extension views of cervical lateral x-rays. We then measured the change in the shortest distance from this horizontal line to the lowest point of the transverse process of C6 between the neutral and extension views. Results: There was a statistically significant difference in the shortest distance from the horizontal line at the surface of the cricoid cartilage to the lowest point of transverse process of C6 between neutral position and neck extension position in both males and females, and between males and females in both neutral position and neck extension position. The cricoid cartilage level was 4.8 mm lower in males and 14.4 mm higher in females than the lowest point of transverse process of C6 in neck extension position. Conclusions: Practitioners should recognize that the cricoid cartilage has cephalad movement in neck extension. In this way, the cricoid cartilage can be still useful as a landmark for stellate ganglion block.

An Analysis and Optimum Design of o Neutral Line Harmonics Eliminating Reactor (중성선 영상고조파 저감용 특수 Reactor 최적설계 연구)

  • Shin, Pan-Seok;Chung, Gyo-Bum;Kim, Han-Deul;Kim, Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.33-41
    • /
    • 2006
  • In the modem power distribution systems, there are lots of zero-phase current harmonics in the neutral power line due to much usages of the controlled switching devices, various semiconductor power converting systems, OA(Office Automation) equipments, PC etc. In order to minimize the current harmonics a zero-phase neutral line current eliminating reactor (NHER) is designed and analyzed its performance using the finite element program. For the design of NHER a program is developed using C++ program. To verify the program a case model(380/220[V], 200[A]) is designed and analyzed by the developed program. As the results of the optimal design, the core loss is reduced by 26[%] with eliminating of the current harmonics. Especially the ninth harmonics is much reduced as compared with the others. When the design of NHER is adapted to the load of the power system, the eliminating effect and efficiency of the device will be much better

Neutral Point Voltage Control for Grid-Connected Three-Phase Three-Level Photovoltaic Inverter (계통연계형 3상 3레벨 태양광 인버터의 중성점 전압제어)

  • Park, Woonho;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.72-77
    • /
    • 2015
  • Three-level diode clamped multilevel inverter, generally known as neutral point clamped (NPC) inverter, has an inherent problem causing neutral point (NP) potential variation. Until now, the NP potential problem of variation has been investigated and lots of solutions have also been proposed. This paper presents a neutral point voltage control technology using the anti-windup PI controller and offset technology of PWM (Pulse Width Modulation) to control the variation of NPC 3-phase three-level inverter neutral point voltage. And the proposed algorithm is tested and verified using a PLL (Phase Locked Loop) in order to synchronize the phase voltage from the line voltage of grid. It significantly improves the voltage balancing under a solar fluctuation conditions of the inverter. Experimental results show the good performance and effectiveness of the proposed method.

Development of robot welding program for gantry-type robot using neutral CAD data format (CAD중립파일을 이용한 켄트리형 ROBOT 자동용접 프로그램개발)

  • CHUNG JAEHOON;SHEEN DONGMOK
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.79-84
    • /
    • 2004
  • In this study, a robot welding programming system is developed for gantry-type robot using a neutral CAD data format. The system automatically extracts welding line data from tile CAD model represented in IGES format and generates a robot program based on the weld line extracted. The welding program is simulated jar verification by using IGRlP, a virtual manufacturing solution. The robot welding programming system is demonstrated with a simple example.

  • PDF

Neutral Line Current Compensation Method of Active Power Filter (전력용 능동 필터의 중성선 전류 저감 기법)

  • Min, Joon-Ki;Kim, Hyo-Sung;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.504-506
    • /
    • 2005
  • This paper proposes a new neutral current reduction method using PQR instantaneous power theory on the active power filter, unbalanced nonlinear load condition in three-phase four-wire systems. For reduction of neutral line current, the single phase active power filter is used and its performance is same with the three-phase four-wire active power filter. For fully-digital implementation, ramp comparison PWM method was adopted. Simulation results verify good performance of the proposed current control strategy on the shunt APFs.

  • PDF

A Calculation of Unbalanced Current on Neutral Line in Two Step Type Pole (2단장주 중성선 불평형 전류 계산)

  • Park, Keon-Woo;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.484-485
    • /
    • 2006
  • The one step type pole and two step type pole are used in KEPCO's distribution system. The neutral current may occurs in three-phase four-wire distribution system due to unbalanced load. This paper presents neutral current both one step type pole and two step type pole in distribution system.

  • PDF

A Study on the NGR problem for harmonic in Distribution system (배전계통의 고조파에 의한 NGR의 문제점에 관한 연구)

  • Park Hee Chul;Cho Nam Hun;Kang Moon Ho;Wang Young peel
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.480-482
    • /
    • 2004
  • This paper presents a study on the NGR problem for harmonic in distribution systems. Overheating of NGR (Neutral Ground reactor), by neutral current in distribution system, is important cause of transformer breakdown of substation. Countermeasures about zero-sequence component harmonic in neutral line are required.

  • PDF

Development of a Static Prosthesis-Alignment Device Using a Force Plate and a Laser Light (힘측정판과 레이저 광을 이용한 정적 의족정렬장치의 개발)

  • 이기원;김기완;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.385-390
    • /
    • 2000
  • The alignment of the prosthetics is very important in an amputee's gait. In the present study. a static prosthesis-alignment device was developed. It consisted of a force plate with four load cells, a laser beam controlled by a step motor, and a control part programmed by PCBASIC. Using the static prosthesis-alignment device, we measured the distance between the load line and various joints of 24 normal volunteers in three standing postures. such as neutral, forward leaning, and backward leaning. Only neutral postures were evaluated on four trans-tibial amputees. The load line for the normal person's neutral position located anterior to the ankle, the knee, and the greater trochanter, but posterior to the shoulder joint. Forward and backward leaning of the normal person resulted in a significant anterior and posterior movements of the load line, respectively. The load line for the amputated side of the trans-tibial amputee also located anterior to the ankle, the extremity prostheses, providing a good relative locations of the load line with respect to various joints.

  • PDF