Modeling and Analysis of PMSMs under Inter Turn Short Faults

  • Choi, Jun-Hyuk;Gu, Bon-Gwan;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1243-1250
    • /
    • 2013
  • A model of a permanent magnet synchronous motor (PMSM) with an inter turn short fault is proposed using a deformed flux model. The deformed flux model includes not only the fault winding flux information but also the inductance variation of the healthy winding considering the configuration of the winding distribution. With the deformed flux model and the positive sequence current assumption, the proposed model is derived in the positive and negative sequence synchronous reference frame (SRF). The finite elements method (FEM) simulation is applied to validate the proposed PMSM model with inter turn short fault.

A Control Strategy to Obtain Sinusoidal Input Currents of Matrix Converter under Unbalanced Input Voltages

  • Nguyen, Thanh-Luan;Lee, Hong-Hee
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.114-116
    • /
    • 2018
  • This paper presents a control strategy to achieve the balanced sinusoidal output currents, as well as sinusoidal input currents for the matrix converter (MC) under unbalanced input voltages. By regulating the modulation index of the converter according to the instantaneous input voltages, the output currents are kept balanced and sinusoidal. In order to obtain sinusoidal input currents, the input power factor angle should be dynamically calculated based on the positive and negative sequence components of the input voltages. This paper proposes a simple method to construct the expected input power factor angle without the complicated sequence component extraction of input voltages. Simulation results are given to validate the effectiveness of the proposed control strategy.

  • PDF

전원전압의 불평형 및 왜곡시 3상 PWM 컨버터의 전류제어 (Current Control of Three-Phase PWM Converters under Unbalanced and Distorted Source Voltage)

  • 장정익;김흥근;이동춘
    • 전력전자학회논문지
    • /
    • 제12권1호
    • /
    • pp.27-36
    • /
    • 2007
  • 본 논문은 전원전압이 불평형이고 왜곡될 경우의 3상 PWM 컨버터의 전류제어기법을 제안한다. 전원전압의 왜곡에 대한 대책은 종래의 일반적인 전류 제어기에 5차, 7차 고조파 전류제어기를 추가하여 전원전류에 저차고조파가 나타나는 것을 제거한다. 그리고 전원전압 불평형의 경우, 역상분 전류제어기를 추가함으로써 전원전류를 평형으로 제어하거나 직류출력 전압의 리플을 감소시킬 수 있다. 제안된 제어 알고리즘의 타당성을 실험을 통하여 검증하였다.

회전기기의 상태감시 및 결함탐지 시스템 (Condition Monitoring and Fault Diagnosis System of Rotating Machinery)

  • 정성학;이영동
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.819-820
    • /
    • 2016
  • 수배전분야는 고압 수배전반, 저압 수배전반, 모터 컨트롤 센터(motor control center; MCC)로 구성되며, MCC는 모터의 운전 및 정지를 할 수 있고, 이상상황 발생 시 비상정지 및 이상 상황에 대한 통보를 할 수 있도록 전자식 모터보호계전기(electronic over current relay; EOCR)가 사용되고 있다. 기존 EOCR은 과전류, 부족전류, 결상, 역상, 전류 불평형, 지락과 같은 전기적 결함 탐지는 가능하지만, 구속보호, 모터 고정자 및 회전자, 베어링 결함과 같은 기계적 결함은 탐지가 어렵다. 본 논문에서는 모터의 전기적, 기계적 결함을 탐지하기 위해 기존 EOCR의 전기적 결함 탐지에 기계적 결함 탐지를 결합하여 회전기기 보호장치를 위한 전기적인 결함과 기계적인 결함을 통합적으로 탐지할 수 있는 시스템을 제안한다. 회전기기 결함탐지를 위한 신호입력부 및 제어부, 시스템 인터페이스, 데이터 획득장치를 설계하였으며, 절연저항 측정, 모터 구속 측정 및 제어, MC 카운터 및 베어링 온도 측정 및 제어를 통해 전기적 결함과 기계적 결함 탐지가 가능하였다.

  • PDF

Improved DPC Strategy of Grid-connected Inverters under Unbalanced and Harmonic Grid Conditions

  • Shen, Yongbo;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.169-175
    • /
    • 2014
  • This paper presents an improved direct power control (DPC) strategy for grid-connected voltage source inverter (VSI) under unbalanced and harmonic grid voltage conditions. Based on the mathematic model of VSI with the negative sequence, 5th and 7th harmonic voltage components consideration, a PI controller is used in the proposed DPC strategy to achieve the average output power regulation. Furthermore, vector PI controller with the resonant frequency tuned at the two times and six times grid fundamental frequency is adopted to regulate both negative and harmonic components, and then two alternative targets of the balanced/sinusoidal current and smooth active/reactive output power can be achieved. Finally, simulation results based on MATLAB validate the availability of the proposed DPC strategy.

다단자 송전계통에서의 1선지락 고장시 고장점 표정 알고리즘 (A Fault Location Algorithm for a Single Line Ground Fault on a Multi-Terminal Transmission Line)

  • 강상희;노재근;권영진
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권2호
    • /
    • pp.121-133
    • /
    • 2003
  • This paper presents a fault location algorithm for a single phase-to-ground fault on 3-terminal transmission systems. The method uses only the local end voltage and current signals. Other currents used for the algorithm are estimated by current distribution factors and the local end current. Negative sequence current is used to remove the effect of load current. Five distance equations based on Kirchhoff's voltage law are established for the location algorithm which can be applied to a parallel transmission line having a teed circuit. Separating the real and imaginary parts of each distance equation, final nonlinear equations that are functions of the fault location can be obtained. The Newton-Raphson method is then applied to calculate the estimated fault location. Among the solutions, a correct fault distance is selected by the conditions of the existence of solution. With the results of extensive S/W and H/W simulation tests, it was verified that the proposed algorithm can estimate an accurate fault distance in a 154kV model system.

Enhanced Proportional-Resonant Current Controller for Unbalanced Stand-alone DFIG-based Wind Turbines

  • Phan, Van-Tung;Lee, Hong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.443-450
    • /
    • 2010
  • An enhanced control strategy for variable-speed unbalanced stand-alone doubly-fed induction generator-based wind energy conversion systems is proposed in this paper. The control scheme is applied to the rotor-side converter to eliminate stator voltage imbalance. The proposed current controller is developed based on the proportional-resonant regulator, which is implemented in the stator stationary reference frame. The resonant controller is tuned at the stator synchronous frequency to achieve zero steady-state errors in rotor currents without decomposing the positive and negative sequence components. The computational complexity of the proposed control algorithm is greatly simplified, and control performance is significantly improved. Finally, simulations and experimental results are presented to verify the feasibility and the robustness of the proposed control scheme.

불평형 부하의 평형화를 위한 STATCOM (STATCOM for Balancing Unbalanced Loads)

  • 임수생;이은웅;임용빈;김홍권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.79-82
    • /
    • 1999
  • In this paper, STATCOH(static synchronous compensator : one of the custom power equipment) is proposed for balancing unbalanced loads. Compensation current references are given by the analysis of the unbalanced 3-phase currents. And for detecting negative-sequence components, digital Butterworth LPF(low pass filter) is used. The predicted current controller in the synchronous rotating coordinates is also proposed. Finally, the effectiveness of STATCOM is verified by the simulations for unbalanced loads.

  • PDF

전류분배계수를 이용한 배전계통 고장점 표정 알고리즘 (A fault location algorithm using current distribution factors for D/S)

  • 이덕수;진보건;이승재;최면송;강상희;안복신;윤남선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.275-277
    • /
    • 2001
  • This paper presents a fault location algorithm using current distribution factors for distribution feeder systems. When a fault occurs in distribution system, an accurate fault distance is important for fast fault restoration. The proposed algorithm achieves a high accuracy using negative sequence circuit with various fault conditions.

  • PDF

자기단 전원임피던스 추정을 이용한 송전선 고장점표정 알고리즘 (Transmission Line Fault Location Algorithm Using Estimated Local Source Impedance)

  • 권영진;김수환;강상희
    • 전기학회논문지
    • /
    • 제58권5호
    • /
    • pp.885-890
    • /
    • 2009
  • A fault location algorithm using estimated local source impedance after a fault is proposed in this paper. The method uses after fault data only at the local end. It uses the negative sequence current distribution factor for more accurate estimation. The proposed algorithm can keep up with the variation of the local source impedance. Therefore, the proposed algorithm especially is valid for a transmission line interconnected to a wind farm that the equivalent source impedance changes continuously. The performance of the proposed algorithm was verified under various fault conditions using the Simpowersystem of MATLAB Simulink. The proposed algorithm is largely insensitive to the variation in fault distance and fault resistance. The test results show a very high accurate performance.