• 제목/요약/키워드: negative pressure

검색결과 1,286건 처리시간 0.03초

A Study on Lubricative Characteristics of Negative Pressure Slider

  • Hwang, Pyung;Park, Sang-Shin;Kim, Eun-Hyo
    • KSTLE International Journal
    • /
    • 제3권2호
    • /
    • pp.110-113
    • /
    • 2002
  • The lubricative characteristics of negative pressure slider were performed by using coordinate transform method. Governing equation is derived by applying generalized coordinate system to the divergence formulation method. This method makes it possible to deal with an arbitrary configuration of a lubricated surface. The pressure profile of the slider is calculated. These results are compared to that from direct numerical method. The steady-state, including minimum film thickness, pitching and rolling angle are calculated by multi-dimensional Newton-Rapshon method. The stiffness and damping characteristics are also calculated.

긴급전환형 임시음압격리병실의 기밀도에 따른 최소 급배기 유량차 평가 (Analysis of Minimum Airflow Differences between Supply and Exhaust Air according to Airtightness of Rapidly Converted Temporary Negative Pressure Isolation Rooms)

  • 신희원;김동욱;김지민;정효범;강동화
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제29권4호
    • /
    • pp.69-77
    • /
    • 2023
  • Purpose: During the COVID-19 pandemic, there have been many cases of converting regular hospital wards into temporary negative pressure isolation wards. The purpose of this study is to evaluate the minimum airflow differences that satisfies the pressure difference criteria(-2.5 Pa) according to airtightness of switching type wards, in preparation for utilization of aging regular wards as negative pressure isolation wards. Methods: Visual inspection and field measurements were conducted using blower door to evaluate airtightness of 5 hospital wards. CONTAM simulation was used to assess the airflow differences when pressure difference between the corridor and wards met the criteria at various levels of airtightness. Results: The ACH50 of evaluated wards ranged from 19.3 to 50.1 h-1 with an average of 37.0 h-1, indicating more than four times leakier than other building types. The minimum airflow differences increased as the airtightness of the wards decreased and the size of the wards increased. Implications: When operating rapidly converted negative pressure isolation wards, understanding airtightness is crucial for determining the minimum airflow differences to maintain the pressure differences. The analysis of this study suggests that improving the airtightness of aging rooms is essential and the minimum airflow differences should be suggested considering both the airtightness and size of rooms.

절대 0도 부근에서 양자터널링에 의한 헬리움(He)액체의 부압하에서의 기포형성 (Bubble Formation in Liquid Helium under Negative Pressure by Quantum Tunneling near Absolute Zero Temperature)

  • 곽호영;정정열;홍재호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.354-359
    • /
    • 2001
  • As the temperature of liquid under negative pressure approaches the absolute zero, the nucleation process due to thermal fluctuations hardly occurs. Instead of this mechanism, quantum fluctuations may lead the formation of nucleus for new phase in metastable state. In this study, the thermal as well as quantum nucleation bubble in liquid helium under negative pressure was investigated theoretically. The energy barrier against nucleation was estimated by molecular interaction due to the Londom dispersion force. It is shown that the phase transition from liquid to vapor in is possible due to the quantum tunneling below 0.2 K for Helium-4 and 0.1 K for Helium-3, at negative pressures close to the ideal tensile strength at which every liquid molecules become bubbles simultaneously.

  • PDF

고압 배관망에서 배관 손상에 의한 누출 및 관내 저압확장파의 전파 특성 해석 (Analysis of Propagation of Negative Pressure Wave Due to Leak Through Damaged Hole in High Pressure Piping System)

  • 김왕연;하종만;하태웅
    • 한국유체기계학회 논문집
    • /
    • 제11권1호
    • /
    • pp.26-32
    • /
    • 2008
  • The safe operation of high pressure pipe line systems is of significant importance. Leaks due to faulty operation from the pipelines can lead to considerable product losses and to exposure of community to dangerous gases. There are several leak detection methods of pipeline network which have recently been suggested. The negative pressure wave detection technology, which has advantages of short time detection availability, accurate leaking location estimate capability and cost effective, is concentrated in this study. Theoretical analysis of the flow characteristics for leaking through a hole on the pipe wall has been performed by using Fluent 6.3, commercial CFD package. The results of 3-dimensional analysis near leaking hole confirm the occurrence of negative pressure wave, and the results of 2-dimensional analysis verify the characteristics of propagation of the wave which travels with speed equal to the speed of sound in the pipeline contents. Characteristics of leakage and pressure in a pipe with a hole have been analyzed for the various pipe and hole sizes.

수동식 부항기의 기계적 안정성과 성능의 실험적 비교연구 (Comparative Study on Cupping Apparatuses for Medical Use by Mechanical Stability and Functional Test)

  • 소문기;송윤경;임형호
    • 한방재활의학과학회지
    • /
    • 제18권2호
    • /
    • pp.157-167
    • /
    • 2008
  • Objectives : It is sure that standardization of medical instruments is very important and necessary. Cupping therapy is one of the traditional oriental medical method, and it is necessary to set up a standard of cupping therapy and instruments. Methods : We select 3 major cupping instrument makers according to a questionnaire survey of 2001 oriental medical doctors. Dae Gun is A maker, Han Sol is B maker, Dong Bang is C maker. And with these air pumps we make experiments on stability by an inner impact test and a falling test. With these cups we check stability by an inner impact test and a disinfection test. And to know function of these instruments we test a negative pressure and maintain attached cups until 5 to 10minutes. Results : All results of experiments(impacted test, disinfection test, falling test) on stability of cups and air pumps are suitable for medical instrument. And the efficiency of 3 major makers shows various results. Negative pressure of B group is the highest, C group is the second, A group is the lowest. Pressure maintenance test shows A and C group is comparatively up to the experimental standard(<10%), B group is comparatively below the experimental standard(<10%). Conclusions : Results show stability of cups and air pumps is suitable for medical instruments. And negative pressure of cupping and maintenance of pressure show various results. So it is necessary to set up a standard negative pressure of cupping and maintenance of pressure.

만성 창상의 치료에서 이동식 음압요법의 신고안 (The Management of Chronic Wound with Modified Portable Negative Pressure Therapy)

  • 김지수;윤인모;유중석
    • Archives of Plastic Surgery
    • /
    • 제35권2호
    • /
    • pp.223-228
    • /
    • 2008
  • Purpose: V.A.C. is a new concept which is closed dressing with negative pressure to promote wound healing. It has been widely used as the treatment of chronic and acute wounds such as pressure sores, burns, stasis ulcers, and other complicated wounds. However It has disadvantages such as high cost and the need of specific equipment. In this article, we described new method to overcome these disadvantages. Methods: We made newly innovated equipment with 50 cc syringe and spring to create negative pressure. From May 2006 to May 2007, we applied it to two patients with chronic wound. Results: The treatment period was 5 weeks for one case and 3 weeks for the other case. Both patients were healed completely without admission and wound healing was accelerated. During follow-ups, there were no complications. The mean cost for single dressing was 9,590 won. Conclusion: Modified portable negative therapy using newly innovated equipment could accelerate wound healing better than conventional dressing. It lowers the number of dressings, saves cost of treatment, and enables treatment as outpatient basis.

Effects of Negative Pressure Soft Tissue Therapy to Ankle Plantar Flexor on Muscle Tone, Muscle Stiffness, and Balance Ability in Patients with Stroke

  • Kim, Kyu Ryeong;Shin, Houng Soo;Lee, Sang Bin;Hwang, Hyun Sook;Shin, Hee Joon
    • 국제물리치료학회지
    • /
    • 제9권2호
    • /
    • pp.1468-1474
    • /
    • 2018
  • The purpose of the study was to investigate the immediate effects of negative pressure soft tissue therapy on muscle tone, muscle stiffness and balance in patients with stroke. In total, 20 patients with stroke and assigned to the negative pressure soft tissue therapy group (NPST, n=10) or, placebo-negative pressure soft tissue therapy group(Placebo-NPST, n=10). Both groups underwent NPST or placebo-NPST once a day during the experimental period. MyotonPRO was used to assess the parameters for muscle tone and stiffness. Biorescue was used to assess the parameters for balance. Each group showed improvements in muscle tone, muscle stiffness, and balance ability (p<.05). Especially, Muscle tone, muscle stiffness, and anterior length in the limit of stability were the significant improvement on NPST group (p<.05). The results of the study suggest that the NPST is effective in improving muscle tone, muscle stiffness, and balance ability in patients with stroke.

음압 창상 처치(Negative pressure wound therapy)에 대한 문헌적 고찰 (Review of negative-pressure wound therapy)

  • 유주리;강재경
    • Journal of Medicine and Life Science
    • /
    • 제15권2호
    • /
    • pp.56-61
    • /
    • 2018
  • NPWT는 90년대 이후 많은 연구가 이루어지며 발전해왔다. 이 기술은 사용하기에 간단하고 다양한 상처에 적용할 수 있고 효용성과 비용-효과가 뛰어나며 부작용이 적다. 따라서 NPWT를 일반적인 드레싱 대신에 사용하면 육아조직의 빠른 성장과 상처 수축을 통해 피부 이식이나 피판이 필요한 부위를 줄일 수 있고 봉합이 불가했던 부위를 가능하게 하므로 창상 환자에 대한 의료 비용을 감소시키고 만성 창상 환자가 입원하지 않고 움직이면서 창상 관리가 가능하도록 할 수 있는 유용한 방법이다.

음압격리병실이 있는 부서에서 근무하는 간호사의 코로나19 감염관리 수행에 영향을 미치는 요인 (The Effect on COVID-19 Infection Control Practice of Nurses who Work in Working Sites with Negative Pressure Isolation Rooms)

  • 박민지;이윤미
    • 중환자간호학회지
    • /
    • 제15권1호
    • /
    • pp.35-46
    • /
    • 2022
  • Purpose : This study aimed to identify the factors affecting coronavirus disease 2019 (COVID-19) infection control practices of nurses in negative pressure isolation rooms. Methods : The participants were 150 nurses working in three hospitals with negative pressure isolation rooms. Data were collected using structured questionnaires and analyzed using an independent t-test, one-way ANOVA, Scheffé test, Pearson correlation coefficients, and multiple regression analysis using the SPSS/WIN 26.0 program. Results : Factors significantly influencing the subject's COVID-19 infection control practice include Being married (𝛽=.18, p =.016), working in a ward with negative pressure isolation rooms (𝛽=.44, p <.001), working in an ICU with negative pressure isolation rooms (𝛽=.27, p =.010), COVID-19 infection control attitude (𝛽=.28, p =.001), anxiety for COVID-19 (𝛽=.30, p <.001). The explanatory power of these variables for COVID-19 infection control practice was 24.6% (F=8.67, p <.001). Conclusion : It is expected that strategies that utilize positive attitudes which believe that COVID-19 disease may be overcome by COVID-19 infection control practice will help improve emerging infectious diseases infection control practice.

음압격리병동의 건축 비구조요소 내진설계를 위한 전산도구 개발 (Development of Computational Tools for Seismic Design of Architectural Components in Negative Pressure Isolation Wards)

  • 추유림;김태진
    • 한국지진공학회논문집
    • /
    • 제26권3호
    • /
    • pp.127-136
    • /
    • 2022
  • Recently, an unprecedented emerging infectious disease has rapidly spread, causing a global shortage of wards. Although various temporary beds have appeared, the supply of wards specializing in infectious diseases is required. Negative pressure isolation wards should maintain their function even after an earthquake. However, the current seismic design standards do not guarantee the negative pressure isolation wards' operational (OP) performance level. For this reason, some are not included in the design target even though they are non-structural elements that require seismic design. Also, the details of non-structural elements are usually determined during the construction phase. It is often necessary to complete the stability review and reinforcement design for non-structural elements within a short period. Against this background, enhanced performance objectives were set to guarantee the OP non-structural performance level, and a computerized tool was developed to quickly perform the seismic design of non-structural elements in the negative pressure isolation wards. This study created a spreadsheet-based computer tool that reflects the components, installation spacing, and design procedures of non-structural elements. Seismic performance review and design of the example non-structural elements were conducted using the computerized tool. The strength of some components was not sufficient, and it was reinforced. As a result, the time and effort required for strength evaluation, displacement evaluation, and reinforcement design were reduced through computerized tools.