다중결함에 의한 부분방전 패턴특성 (PD Characteristics of Multi-Defects System)

  • 이준호;이철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2411-2413
    • /
    • 1999
  • Regarding the application of diagnistic technology using PD signal to power apparatus, it is necessary to discriminate the type of defect as well as to determine whether the PD occurs or not. In this research, PD characteristics of multi-defects insulating system were presented, the PD signals were detected from three kinds of electrode systems, IEC(b), needle-plane and CIGRE method II. To make multi-defect systems artificially, we combined three electrode systems and applied same test voltage simultaneously.

  • PDF

가스절연 구조에서 단일 부분방전펄스 분석에 의한 결함 판별 (Identification of Defect Type by Analysis of a Single PD Pulse in Gas Insulated Structure)

  • 조향은;김선재;정기우;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제28권5호
    • /
    • pp.320-325
    • /
    • 2015
  • This paper dealt with a defect identification algorithm which is based on single partial discharge (PD) pulse analysis in gas insulated structure. Four types of electrode systems such as a needle-plane, a plane-needle, a free particle and a crack inside spacer were fabricated to simulate defects in gas insulated switchgear (GIS). We measured single PD pulse by an oscilloscope with a sampling rate of 5 GS/s and a frequency bandwidth of 1 GHz. Data aquisition and signal processing were controlled by a LabVIEW program. Physical shapes of PD pulses were compared with kurtosis, skewness and time-based parameters as rising time, falling time and pulse-width. These parameters were analysed by an algorithm with a back propagation algorithm (BPA). By applying the algorithm, the identification rate was 97% for the needle-plane electrode, 96% for the plane-needle electrode, 91% for the free particle and 93% for the crack inside spacer. The results verified that the algorithm could identify the type of defects in GIS.

전력케이블에서 교류전압과 진동파 전압을 이용한 부분방전 측정 (Partial Discharge Detection for the Power Cables using AC and Oscillating wave Voltage)

  • 김정태;김남준;이전선;구자윤
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권4호
    • /
    • pp.247-252
    • /
    • 1999
  • In this paper, in order to investigate availability of the OW-PD measurement method which has been proposed as an alternative of AC-PD measurement method to an after laying test and/or diagnosis for the power cable system, partial discharges owing to the needle-type defect integrated into the cable have been measured using AC and OW(Oscillating Wave) voltages. In the AC-PD measurement, the magnitude, phase and pulse number of partial discharges have been changed with the duration of voltage application, which can be analyzed through the relation with the process of the electrical tree initiation and propagation. In addition, the characteristics of partial discharges using OW voltage are appeared to be similar to those in case of AC-PD measurement and to be different with the shapes of electrical tree. From these results, it is concluded that the OW-PD measurement method is available to the tests for the cable system.

  • PDF

다중결함 부분방전의 패턴특성 연구 (A Study on Pattern Characteristics of Multi-Defect Partial Discharge)

  • 이준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.970-972
    • /
    • 1998
  • In practice, there may be various defects in an insulating system, so that the PD signals can be produces from these defect simultaneously. Regarding these situations, we have to discriminate the type of defect as well as to determine whether the PD occurs or not. In our research. some analysis results of the PD signals from multi-defects insulating system will be presented. We measure the PD signals using three kind of electrode system: IEC(b). Needle-Plane and mixed electrodes. To simulate multi-defect systems, we combine two electrode systems and apply test voltage simultaneously. Neural network, statistical analysis methods will be tested, and the possibilities and limitations of each method will be clarified.

  • PDF

Morphological and Chemical Analysis of Various Disposable Acupuncture Needles Used in South Korea

  • Dong Yong, Park;JiYoon, Ahn;Hyeon Jeong, Park;Doo Suk, Lee;Dae-Hyun, Jo;Jonghoon, Kim;Choulmin, Kim;Heebum, Chung;Ji Hye, Hwang
    • 대한약침학회지
    • /
    • 제25권4호
    • /
    • pp.382-389
    • /
    • 2022
  • Objectives: The Korean Industrial Standard (KS) for sterile acupuncture needles was established in 2009 based on research on the quality control of acupuncture needles. We aimed to determine the quality of acupuncture needles available in South Korea in 2021 by examining their surface condition and chemical composition using field-emission scanning electron microscopy (FE-SEM) and energy-dispersive X-ray spectroscopy (EDS). Methods: In South Korea, there are 23 brands of acupuncture needles, and we examined 10-15 needles from each brand, resulting in a total of 285 needles. The microstructures of the needles were assessed by SEM. Using SEM images, we evaluated the acupuncture needle tips for the following defects/aspects: scratches, lumps, detached coating, bent tip, and tip sharpness. EDS was used to determine the chemical composition of the selected acupuncture needles. Results: Overall, 88.4% of 285 needles were found to have at least one type of abnormality. The most frequently observed abnormalities were scratches and dents on the surface (68.1%), followed by detached coating (63.2%), and lumps (61.8%); blunt tips were observed in about 24% of them. Of 252 needles with at least one defect, 86.9% had two or more types of defects. The ratio of the number of needles with any defect to that of needles without any defect varied among brands, ranging from 50% to 100%. Regarding foreign materials, higher proportions of Si and O were observed on the needles, indicating incomplete or detached silicone coating. Conclusion: The quality of acupuncture needles varied among brands, suggesting that further improvements can be made through various inspection methods.

A Study on the Partial Discharge Patterns from Multi-Defect Insulating Systems

  • Lee, June-Ho;Tatsuki Okamoto
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.170-173
    • /
    • 1998
  • In practice, there may be various defects in an insulating system, so that the PD signals can be produced from these defects simultaneously. Regarding these situations, we have to discriminate the type of defect as well as determine whether the PD occurs or not. In this paper, some analysis results of the PD signals from multi-defects insulating system were presented. We measure the PD signals by using three kind of electrode system, IEC(b), Needle-Plane and mixed electrodes. To simulate multi-defect systems, we combined to electrode systems and apply test voltage simultaneously. Neural network, statistical analysis methods were tried, and the possibilities and limitations of each method were clarified.

  • PDF

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.

초저주파전원을 이용한 지중배전 전력케이블의 결함검출 (Defects Detection of the Underground Distribution Power Cables by Very Low Frequency Voltage Source)

  • 김주용;송일근
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.45-50
    • /
    • 1998
  • 본 논문은 기존의 지중배전케이블의 준공시험으로 사용되고 있는 DC시험을 대체 하기 위한 초저주파 전원의 적용결과로서, 실험실에서 제작한 5m 길이의 실제 케이블의 칼흠집 결함과 침결함에 대해 초저주파 전원의 결함검출 능력을 평가하였다. 이 시험에서 초저주파 시험은 케이블 절연체 내부에 존재하는 결함부위에서 전기트리 개시는 어렵지만, 일단 전기트리가 개시되면 트리의 진전이 매우 빠르고 내부결함이 검출되지 않는 경우, 시험으로 인한 새로운 결함이 형성되거나 결함이 더 확대되지 않는 것으로 나타났다. 따라서 초저주파전원은 지중배전선로의 현장시험용으로 적용되기보다는 제조업체의 품질검사 확인용으로 사용하는 것이 효과적이라 판단된다.