• Title/Summary/Keyword: near-infrared absorption

Search Result 174, Processing Time 0.027 seconds

Low Resolution Near-Infrared Stellar Spectra Observed by CIBER

  • Kim, MinGyu;Lee, Hyung Mok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.76.2-76.2
    • /
    • 2016
  • We present near-infrared (0.8 - 1.8 microns) spectra of 63 bright (J_mag < 10) stars observed with Low Resolution Spectrometer (LRS) onboard the rocket-borne Cosmic Infrared Background Experiment (CIBER). Two Micron All Sky Survey (2MASS) photometry information is used to find cross-matched stars after reduction and extraction of the spectra. We identify the spectral types of observed stars by comparing with spectral templates from the Infrared Telescope Facility (IRTF) library. All the observed spectra are consistent with late F to M stellar spectral types, and we identify various infrared absorption lines. As our observations are performed above the Earth's atmosphere, our spectra are free from telluric contamination. Including HST/NICMOS and Cassini/VIMS, the spectral coverage has rarely been achieved in space, and the methods developed here can inform statistical studies with future low-resolution spectral measurements such as GAIA photometric and radial velocity spectrometer.

  • PDF

A new method for mapping visible-near infrared light levels in Fruit

  • Fraser, Daniel G.;Jordan, Robert B.;Kunnemeyer, Rainer;Mcglone, V. Andrew
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1128-1128
    • /
    • 2001
  • We have developed a probe for measuring the light levels inside illuminated fruit. The probe has minimal effect on the light levels being measured and enables the sampling of the light flux at any point within the fruit. We present experimental light extinction rates within apple, nashi, kiwifruit, and mandarin fruit. Moving from the illuminated side to the far side of the fruit, the extinction level follows an initial power law decay as the light diffuses into the fruit then reduces to an exponential decay through the rest of the fruit. Significant variations in the rates of light extinction are found in the core, skin and differing flesh regions. Monte Carlo simulations of the light distribution in fruit, which use scattering and absorption coefficients for the diffusely scattering tissue, and boundary conditions for the skin effects, produce results that follow the experimental results closely.

  • PDF

Medical Applications of Near Infrared Spectroscopy and Diffuse Optical Imaging (Review) (근적외선 분광법 및 확산 광 영상법의 최근 연구 동향)

  • Lee, Seung-Duk;Kwon, Ki-Won;Koh, Dal-Kwon;Kim, Beop-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.89-98
    • /
    • 2008
  • NIRS (Near-infrared Spectroscopy) and DOI (Diffuse Optical Imaging) are relatively new, non-invasive, and non-ionizing methods that measure or image optical properties (Scattering and Absorption Coefficient) and physiological properties (Water Fraction, concentration of Oxy-, Deoxy-Hemoglobin, Cytochrome Oxidase, etc) of biological tissues. In this paper, three different types of NIRS systems, mathematical modeling, and reconstruction algorithms are described. Also, recent applications such as functional brain imaging, optical mammography, NIRS based BMI (Brain-Machine Interface), and small animal study are reviewed.

The Effect of Solvent and Doping Matter on the Electric Properties of Polyaniline Films (폴리아닐린 필름의 전기적 특성에 미치는 용매 및 도핑물질의 효과)

  • 김재욱
    • Electrical & Electronic Materials
    • /
    • v.10 no.7
    • /
    • pp.713-718
    • /
    • 1997
  • Polyaniline free standing films cast from N-methyl-2-pyrrolidinone(NMP) solution, camphorsulfonic acid(HCSA), dodecylbenzensulfonic acid(HDBSA), inorganic matter(carbon black, graphite) and metal(silver) were prepared by processings. The properties of these films such as crystallinity, near-infrared absorption spectra and conductivity were investigated. The HCSA and HDBSA doped polyaniline films cast from m-cresol and chloroform solvents showed the metallic property and high crystallinity, respectively. The value of conductivity in the HCSA doped polyaniline film obtained 180 S/cm. We have obtained the value of conductivity 200 S/cm in the metal(silver) doped polyaniline film, which is higher than that of the HCSA doped polyaniline film. The metal(silver) doped polyaniline film shows good properties as a electromagnetic shielding material.

  • PDF

Frequency-domain Diffuse Optical Tomography System Adopting Lock-in Amplifier (Lock-in 증폭기를 채용한 주파수영역 확산 광단층촬영 시스템)

  • Jun, Young-Sik;Baek, Woon-Sik
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.3
    • /
    • pp.134-140
    • /
    • 2011
  • In this paper, we developed a frequency-domain diffuse optical tomography(DOT) system for non-invasively imaging in vivo. The system uses near-infrared(NIR) light sources and detectors for which the photon propagation in human tissue is dominated by scattering rather than by absorption. We present the experimental reconstruction images of absorption and scattering coefficients using a liquid tissue phantom, and we obtain the location and shape of an anomaly which has different optical properties than the phantom.

Rancidity Prediction of Soybean Oil by Using Near-Infrared Spectroscopy Techniques

  • Hong, Suk-Ju;Lee, Ah-Yeong;Han, Yun-hyeok;Park, Jongmin;So, Jung Duck;Kim, Ghiseok
    • Journal of Biosystems Engineering
    • /
    • v.43 no.3
    • /
    • pp.219-228
    • /
    • 2018
  • Purpose: This study evaluated the feasibility of a near-infrared spectroscopy technique for the rancidity prediction of soybean oil. Methods: A near-infrared spectroscopy technique was used to evaluate the rancidity of soybean oils which were artificially deteriorated. A soybean oil sample was collected, and the acid values were measured using titrimetric analysis. In addition, the transmission spectra of the samples were obtained for whole test periods. The prediction model for the acid value was constructed by using a partial least-squares regression (PLSR) technique and the appropriate spectrum preprocessing methods. Furthermore, optimal wavelength selection methods such as variable importance in projection (VIP) and bootstrap of beta coefficients were applied to select the most appropriate variables from the preprocessed spectra. Results: There were significantly different increases in the acid values from the sixth days onwards during the 14-day test period. In addition, it was observed that the NIR spectra that exhibited intense absorption at 1,195 nm and 1,410 nm could indicate the degradation of soybean oil. The PLSR model developed using the Savitzky-Golay $2^{nd}$ order derivative method for preprocessing exhibited the highest performance in predicting the acid value of soybean oil samples. onclusions: The study helped establish the feasibility of predicting the rancidity of the soybean oil (using its acid value) by means of a NIR spectroscopy together with optimal variable selection methods successfully. The experimental results suggested that the wavelengths of 1,150 nm and 1,450 nm, which were highly correlated with the largest absorption by the second and first overtone of the C-H, O-H stretch vibrational transition, were caused by the deterioration of soybean oil.

Nondestructive determination of humic acid in compost by NIRS

  • Seo, Sang-Hyun;Han, Xiao-Ri;Cho, Rae-Kwang;Park, Woo-Churl
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1623-1623
    • /
    • 2001
  • Composting is a biological method used to transform the organic waste into stable, humified organic amendments. Humification is indicated as the key factor in improving the quality of compost, because of the importance of humic substances to soil ecology, fertility and structure, and their beneficial effects on plant growth The compost constituents vary widely, however, the degree of maturity is very important factor in compost quality. So this experiment carried out to determine the rapid estimation of the quality in cattle, pig, chicken and waste composts using near infrared reflectance spectroscopy(NIRS). Near infrared reflectance spectra of composts was obtained by Infra Alyzer 500 scanning spectrophotometer at 2-nm intervals from 1100 to 2500nm. Multiple linear regression(MLR) or partial least square regression (PLSR) was used to evaluate a NIRS method for the rapid and nondestructive determination of humic acid contents in composts. The results summarized that NIR spectroscopy can be used as a routine testing method to determine quantitatively the humic acid content in the compost samples ondestructively. Especially, we supposed that absorbance around 2300nm is related to humic acid as a factor of compost maturity. However the NIR absorption approach is empirical, it actually requires many combinations of samples and data manipulations to obtain optimal prediction.

  • PDF

Measurement of lipid content of compost fermentation using near-infrared spectroscopy

  • Daisuke Masui;Suehara, Ken-ichiro;Yasuhisa Nakano;Takuo Yano
    • Near Infrared Analysis
    • /
    • v.2 no.1
    • /
    • pp.37-42
    • /
    • 2001
  • Near infrared spectroscopy (NIRS) was applied to determination of the lipid content of the compost during the compost fermentation of tofu (soybean0curd) refuse. The absorption of lipid observed at 5 wavelengths, 1208, 1712, 1772, 2312 and 2352 nm on the second derivative spectra. To formulated a calibration equation, a multiple linear regression analysis was carried out between the near-infrared spectral data and on the lipid content in the calibration sample set (sample number, n=60) obtained using Soxhlet extraction method. The value of the multiple correlation coefficient (R) was 0.975 when using the wavelengths of 1208 and 1712 nm were used in the calibration equation. To validate the calibration equation obtained, the lipid content in the validation sample set (n=35) not used for formulating the calibration equation was calculated using the calibration equation, and compared with the value obtained using the Soxhlet extraction method. Good agreement was observed between the results of the Soxhlet extraction method and those values of the NIRS method. The simple correlation coefficient (r) and standard error of prediction (SEP) were 0.964 and 0.815 %, respectively. suitability of the lipid content as an indicator of the compost fermentation of tofu refuse was also studied. The decrease of the lipid content in the compost corresponded to the decrease of the total dry weight of the compost in the composter. The lipid content was a significant indicator of the compost fermentation. The NIRS method was applied to measure the time course of the lipid content in the compost fermentation and good results were obtained. The study indicates that NIRS is a useful method for process management of the compost fermentation of tofu refuse.

THE ANALYSIS OF EFFLUENT GAS FROM ETHYLENE FURNACE BY NEAR-INFRARED SPECTROSCOPY

  • Lee, Joon-Sik;Kim, Jeong-Hyen;Cho, In-Ho
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1192-1192
    • /
    • 2001
  • Usually there are many furnaces in a ethylene plant and the performance of total furnaces can be improved if that of each furnace is monitored and controlled. For this purpose real-time data for the effluent of each furnace is necessary. However, it is very difficult to analyze the total effluent stream of a ethylene furnace by real-time because it is composed of so many components including heavy hydrocarbons. Fortunately, component data for lighter hydrocarbons is much more important than that of heavier ones for ethylene furnace. In ordinary case, the on-line measurement of light hydrocarbons is performed by on-stream gas chromatography, after separating gas-phase part from effluent. The main and important components of gas-phase are Methane, Ethane, Ethylene, and Propylene. If we can use Near-infrared spectroscopy for measuring those components within good reproducibility, shorter analysis time, better repeatability, easier maintenance and lower cost will make Near-infrared (NIR) analyzer replace on-stream gas chromatography in this process. Although it is known to be very difficult to measure gas components because of very weak absorption in Near-infrared region, we have studied the feasibility of the application of NIR for the measurement of gas-phase hydrocarbon in the effluent of ethylene furnace. The samples were obtained from actual process and NIR spectra were collected over 1100 to 2500nm range. NIR spectra and calibrations showed and demonstrated the possibility of extending NIR spectroscopy to the measurement of gas-phase hydrocarbon in the effluent of ethylene furnace.

  • PDF

Measurement of Lipid Content of Compost in the fermentation Process using Near-Infrared Spectroscopy

  • Suehara, Ken-Ichiro;Masui, Daisuke;Nakano, Yasuhisa;Yano, Takuo
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1254-1254
    • /
    • 2001
  • Near infrared spectroscopy (NIRS) was applied to determination of the lipid content of compost during compost fermentation of tofu(soybean-curd) refuse. The reflected rays in the wavelength range between 800 and 2500 nm were measured at 2 nm intervals. The absorption of lipid observed at 4 wavelengths, 1208, 1712, 2312 and 2352 nm on the second derivative spectra. To formulate a calibration equation, a multiple linear regression analysis was carried out between the near-infrared spectral data and on the lipid content in the calibration sample set (sample number, n=60) obtained using a Soxhlet extraction method. The calibration equation for prediction of lipid, the value of the multiple correlation coefficient (R) was 0.975 when using the wavelengths of 1208 and 1712nm. To validate the calibration equation obtained, the lipid content in the validation sample set (n=35) not used for formulating the calibration equation were calculated using the calibration equations, and compared with the values obtained using the Soxhlet extraction method. Good agreement were observed between the results of the Soxhlet extraction method and those values of the NIRS method. The simple correlation coefficient (r) and standard error of prediction (SEP) were 0.964 and 0.815 %, respectively. Then, the NIRS method was applied to a compost fermentation in which the time course the lipid content were measured and good results were obtained. The study indicates that NIRS is a useful method for process management of the compost fermentation of tofu refuse.

  • PDF