• Title/Summary/Keyword: near-field optics

Search Result 107, Processing Time 0.027 seconds

Developing a Cantilever-type Near-field Scanning Optical Microscope Using a Single Laser for Topography Detection and Sample Excitation

  • Ng'ang'a, Douglas Kagoiya;Ali, Luqman;Lee, Yong Joong;Byeon, Clare Chisu
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.229-237
    • /
    • 2021
  • The capabilities of the near-field scanning optical microscope (NSOM) for obtaining high resolution lateral topographical images as well as for mapping the spectroscopic and optical properties of a sample below the diffraction limit of light have made it an attractive research field for most researchers dealing with optical characteristics of materials in nano scales. The apertured NSOM technique involves confining light into an aperture of sub-wavelength size and using it to illuminate a sample maintained at a distance equal to a fraction of the sub-wavelength aperture (near-field region). In this article, we present a setup for developing NSOM using a cantilever with a sub-wavelength aperture at the tip. A single laser is used for both cantilever deflection measurement and near-field sample excitation. The laser beam is focused at the apex of the cantilever where a portion of the beam is reflected and the other portion goes through the aperture and causes local near-field optical excitation of the sample, which is then raster scanned in the near-field region. The reflected beam is used for an optical beam deflection technique that yields topographical images by controlling the probe-sample in nano-distance. The fluorescence emissions signal is detected in far-field by the help of a silicon avalanche photodiode. The images obtained using this method show a good correlation between the topographical image and the mapping of the fluorescence emissions.

Making sung lass lens by using ferrite plating and the effect of cutting off ultraviolet (페라이트 도금법에 의한 선글라스 렌즈의 제작과 자외선 차단효과)

  • Ha, T.W.;Cha, J.W.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.1
    • /
    • pp.35-38
    • /
    • 2002
  • Ferrite thin film with glass substrate was prepared by ferrite plating method in order to make sunglass which cut off ultraviolet and electromagnetic field. It has single phase of polycrystalline spinel structure and has gloss like as mirror and has hardness without scratch by scraping with nail. The transmittance of ferrite thin film is lowered near 400nm manifestly, which shows that the ferrite thin film was cut off ultraviolet successfully. Therefore, the sunglass with ferrite plating is use of cut of ultraviolet and electromagnetic field.

  • PDF

Magnetic Resonance Imaging Meets Fiber Optics: a Brief Investigation of Multimodal Studies on Fiber Optics-Based Diagnostic / Therapeutic Techniques and Magnetic Resonance Imaging

  • Choi, Jong-ryul;Oh, Sung Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.218-228
    • /
    • 2021
  • Due to their high degree of freedom to transfer and acquire light, fiber optics can be used in the presence of strong magnetic fields. Hence, optical sensing and imaging based on fiber optics can be integrated with magnetic resonance imaging (MRI) diagnostic systems to acquire valuable information on biological tissues and organs based on a magnetic field. In this article, we explored the combination of MRI and optical sensing/imaging techniques by classifying them into the following topics: 1) functional near-infrared spectroscopy with functional MRI for brain studies and brain disease diagnoses, 2) integration of fiber-optic molecular imaging and optogenetic stimulation with MRI, and 3) optical therapeutic applications with an MRI guidance system. Through these investigations, we believe that a combination of MRI and optical sensing/imaging techniques can be employed as both research methods for multidisciplinary studies and clinical diagnostic/therapeutic devices.

Cold Atomic Beam Extracted by Zeeman Effect (제만 효과를 이용한 저온 원자빔)

  • Kim, Kihwan;Noh, Heung-Ryoul;Wonho Jhe
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.250-251
    • /
    • 2001
  • There is a considerable interest in the generation of a cold atomic beam having a narrow velocity spread that can be used in various experiments in physics such as ultrahigh resolution atomic and molecular spectroscopy, atom optics, atom interferometry, study of solid surfaces, and low energy collision experiments. The invention of the techniques of laser cooling has stimulated developments in the production of cold and bright atomic beams. (omitted)

  • PDF

A study on the feedback control system for near field scanning optical microscope based on the tuning fork oscillator (수정 진동자를 이용한 근접장광학계 (Near-Field Scanning Optical Microscope) 제작 및 특성연구)

  • 윤선현
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.4
    • /
    • pp.267-272
    • /
    • 1999
  • We attached a fiber tip on the branch of a quartz crystal oscillator in order to make a feedback control system for near field optical microscope. The electrical impedance of the quartz crystal oscillator depends on the distance between the surface of the sample and the tip caused by the surface damping. Using this method, we can directly monitor the distance between the sample and the tip without inserting extra beam which might give extra optical noise. We characterize the XY scanning resolution and the amplitude of the vibrating tip and the Z-dependent decay of the evanescent wave.

  • PDF

Analysis of Cassegrain Dual Offset Reflectors for Compact Payload Test Range (CPTR용 카세그레인 오프셋 복 반사경의 해석)

  • Rho, Sung-Min;Choi, Hak-Keun;Lim, Sung-Bin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.1
    • /
    • pp.46-53
    • /
    • 2008
  • In general, the cassegrain dual offset reflector is used for the satellite communication antenna, but is analyzed as the reflector system for the CPTR(Compact Payload Test Range) facility in here. The near-field at the test zone of the CPTR is obtained by using the physical optics approximation. The CPTR has to provide a uniform plane wave with the minimum amplitude and phase ripple and the low cross polarization. Therefore, in this paper, the near-field pattern are calculated, and the ripple and taper of the field and the cross polarization are investigated with the variation of the reflector geometry and the position of the test region. Especially, the cross polarization of the antenna axis direction which is not found in the satellite reflector antennas is investigated.

Science with the Giant Magellan Telescope Integral-Field Spectrograph

  • Lee, Jae-Jun;Park, Byeong-Gon;Hwang, Na-Rae;Lee, Jun-Hyeop
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.68.2-68.2
    • /
    • 2013
  • The Giant Magellan Telescope Integral-Field Spectrograph (GMTIFS) is a near-infrared imager and integral-field spectrograph, which will be the workhorse adaptive-optics (AO) instrument on the GMT when AO operations begin. We will describe the current design and proposed capabilities of the GMTIFS. We will also present a brief overview of GMTIFS science cases that include first-light objects, galaxy feedback and assembly, the nature of compact massive objects as well as the formation and evolution of stars and planets.

  • PDF

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

Near-field Evaluation of Surface Plasmon Resonance Biosensor Sensitivity Based on the Overlap Between Field and Target Distribution (근접장-분자반응 간의 중첩을 이용한 표면 플라스몬 공명 센서 감도 평가에 관한 연구)

  • Ryu, Yeonsoo;Son, Taehwang;Kim, Donghyun
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.86-91
    • /
    • 2013
  • In this study, we have investigated the correlation of far-field detection sensitivity of surface plasmon resonance (SPR) biosensors with optical signatures associated with the near-field overlap of biomolecules. The results confirm a direct relation between the far-field and near-field parameters, particularly for optical signatures defined in terms of lateral electric field components that are tangential to the interface and thus continuous across the interface. The overall correlation between near-field optical signatures and far-field resonance shift exceeded 97%. The results can be highly useful to evaluate detection sensitivity of SPR biosensors that take advantage of complex structures for localization of surface waves.

Optical Design of an Off-axis Five-mirror-anastigmatic Telescope for Near Infrared Remote Sensing

  • Li, Xing Long;Xu, Min;Pei, Yun Tian
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.343-348
    • /
    • 2012
  • This paper described an off-axis five-mirror-anastigmatic telescope. It is composed of three aspheric surfaces and one spherical surface while the third mirror and fifth mirror have the same parameters at the same place. This configuration is useful for having wide field of view. The strip full field of view for the near infrared telescope is $20^{\circ}{\times}0.2^{\circ}$. The entrance pupil is located in front of the first mirror. There is an intermediate image between the second mirror and the third mirror. The entrance pupil diameter is 100 mm and the effective focal length is 250 mm. The spectral range is $0.85-1.75{\mu}m$. The pixel pitch is $15{\mu}m$. The image quality is near the diffraction limit. Some methods were used to restrain the stray light such as a field stop near the intermediate image, the baffle, the narrow-band pass filter and a stop in front of the focal plane.