• Title/Summary/Keyword: near transfer

Search Result 878, Processing Time 0.034 seconds

Preliminary Study of a Turbopump Pyro Starter (터보펌프 파이로 시동기 기초연구)

  • Hong, Moon-Geun;Lee, Soo-Yong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.2
    • /
    • pp.74-80
    • /
    • 2008
  • The feasibility study into the development of turbine spinners, which start up the turbo-pump, has been carried out and the design requirements and parameters ranges have been presented. Turbine spinners use the solid propellant as such composite propellant based AN compound with high energy plasticizers, coolants, and phase stabilizer which relieves a sensible volume change due to the phase transformation of AN near room temperature. Propellants which have a homing rate of $0.2{\sim}0.3\;mm/s$ and pressure exponent ranged from 0.3 to 0.6, showed stable burn-out in the standard motor tests. Both the magnitude of ignition energy and its thermal transfer mechanism have been proved to have a tangible effect on the ignition of the pyre starter, and the results of this study showed that a flame temperature of 1400K would be quite adequate to get a stable ignition for the AN composite propellant.

QoS control function for Triple Play Service based on E-PON (E-PON기반 Triple Play Service를 위한 QoS 제어 기능)

  • Park, Chun-Kwan;Song, Han-Young;Jeon, Byung-Chun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.68-77
    • /
    • 2007
  • In this paper, we address TPS (Triple Play Service) based on E-PON and also develop QoS control function for both directions, which is disadvantage of E-PON. E-PON technology has the configuration suitable for TPS, but relatively the large delay characteristics in upstream, so if QoS control function must be supported to transfer the real time traffic for both directions, E-PON technology can support TPS efficiently. Therefore, in this paper, we address the diverse requirements of quality for TPS, and then develop TPS platform to verify the quality characteristics according to QoS characteristics of each element in real environment based on this. This result will be used to improve the quality of TPS that become conventional in near future. ISP will use this result as the basis in establishing quality reference and as the guidance in developing new system.

The Correlation of Heavy Metal Contents in Herbal Medicines and Their Soils at North Gyeongbuk Area (경북북부지역 한약재와 재배토양중의 중금속과의 상관관계)

  • Park Moon-Ki;Lee Hyeun-Jeung;Kim Kwang-Joong;Moon Young-Soo
    • Journal of Environmental Science International
    • /
    • v.14 no.2
    • /
    • pp.185-192
    • /
    • 2005
  • The concentration of heavy metal were studied for the estimation of quality in herbal medicines which is Bupleuri Radix, Paeoniae Radix, Dioscoreae Rhizoma and Astragali Radix in products of north Gyeongbuk area Also, we collected soils from several area in Gyeongbuk, and determined heavy metal concentration of soils by ICP. We compared with herbal medicines in products of Gyeongbuk and their soils. The average levels of heavy metal of herbal medicines in Gyeongbuk area are as follows: Mercury is 0.037mg/kg, Chromium is 0.093 mg/kg, Nickel is 0.108mg/kg, Copper is 0.475mg/kg, Zinc is 3.14mg/kg, Manganese is 1.52mg/kg, Iron is 7,83mg/kg, and Cadmium, Lead and Arsenic is not detected. It was very lower in concentrations than those of average Korea area. For the heavy metals contents of Gyeongbuk area, in Gong Jung Ri, represented the higher level, it may be due to a near the road. The Cd contents in soil was not a wide difference. For the As and Pb contents in soil, Song Sa Ri (Bupleuri Radix) represented the higher level(0.68mg/kg, 1523mg/kg). Correlation coefficients of heavy metal contents in cultured herbal medicines and their soils did not give reproducible results. But the degree of correlation between a few heavy metal contents of Dioscoreae Rhizoma and their soil showed the good transfer from the soil.

Effects of Two-dimensional Heat and Mass Transports on Condensational Growth of Soot Particles in a Tubular Coater (원형관 코팅장치에서 연소 입자의 응축성장에 미치는 2차원 열 및 물질전달의 영향)

  • Park, Sung Hoon
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.163-171
    • /
    • 2013
  • Soot particles emitted from combustion processes are often coated by non-absorbing organic materials, which enhance the global warming effect of soot particles. It is of importance to study the condensation characteristics of soot particles experimentally and theoretically to reduce the uncertainty of the climate impact of soot particles. In this study, the condensational growth of soot particles in a tubular coater was modeled by a one-dimensional (1D) plug flow model and a two-dimensional (2D) laminar flow model. The effects of 2D heat and mass transports on the predicted particle growth were investigated. The temperature and coating material vapor concentration distributions in radial direction, which the 1D model could not accounted for, affected substantially the particle growth in the coater. Under the simulated conditions, the differences between the temperatures and vapor concentrations near the wall and at the tube center were large. The neglect of these variations by the 1D model resulted in a large error in modeling the mass transfer and aerosol dynamics occurring in the coater. The 1D model predicted the average temperature and vapor concentration quite accurately but overestimated the average diameter of the growing particles considerably. At the outermost grid, at which condensation begins earliest due to the lowest temperature and saturation vapor concentration, condensing vapor was exhausted rapidly because of the competition between condensations on the wall and on the particle surface, decreasing the growth rate. At the center of the tube, on the other hand, the growth rate was low due to high temperature and saturation vapor concentration. The effects of Brownian diffusion and thermophoresis were not high enough to transport the coating material vapor quickly from the tube center to the wall. The 1D model based on perfect radial mixing could not take into account this phenomenon, resulting in a much higher growth rate than what the 2D model predicted. The result of this study indicates that contrary to a previous report for a thermodenuder, 2D heat and mass transports must be taken into account to model accurately the condensational particle growth in a coater.

Analysis of the Inundation Potential by Elevation for the Land Evaluation in the Potentially Inundated Farms - A Case Study in Ibang-myeon, Changnyeong-gun, Kyungsangnamdo - (상습침수 농경지의 토지평가를 위한 고도별 침수 잠재성 분석 - 경상남도 창녕군 이방면을 대상으로 -)

  • Park In-Hwan;Jang Gab-Sue;Seo Dong-Joe
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.2 s.109
    • /
    • pp.71-82
    • /
    • 2005
  • A large scale of riverside rearrangement has been recently done in the major rivers in Korea. So inundation possibility in agricultural area closed by these rivers has been higher than the possibility a few years ago. However, land use in this area has not been adjusted to a change of this situation near the rivers. Therefore, when typhoon or heavy rain is happened on this area, it can cause a large damage in agricultural area. This study analyzed inundation potentiality in agricultural area at Ibang-myeon, Changnyeong-gun, Kyeongnam-province, Korea by using the logistic regression model and the piecewise regression model. The first thing we did was to transfer the inundation area per elevation to the accumulated inundation area per elevation. This accumulated inundation area per elevation as an distribution function could be described by the logistic regression model(LRM), and piecewise regression model(PRM) could make it much more accurate to analyze the inundation area per elevation. As a result, the regression models derived from LRM and PRM showed $R^2$ over 0.950. The models derived from LRM and PRM in Ibang-myeon noted that frequently inundated area(FIA) was shown up to 12.12m in elevation, and potentially inundated area(PIA) was shown up to 14.60m in elevation. In FIA, regular agricultural activity would be impossible. And It would be not easy to continue the regular agricultural activity in PIA. So, this land should be rearranged to be used for a buffer zone for ecosystem protection, landscape conservation and things like that in riverside.

Damping Inter-area Low Frequency Oscillations in Large Power Systems with $H_{\infty}$ Control of TCSC PARTI : TCSC Siting (TCSC의 $H_{\infty}$ 제어에 의한 대규모 전력계통의 지역간 저주파진동 억제 PartI : 설치지점 선정)

  • Kim, Yong-Gu;Sim, Gwan-Sik;Song, Seong-Geun;Kim, Yeong-Hwan;Nam, Hae-Gon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.5
    • /
    • pp.226-232
    • /
    • 2000
  • This paper presents application results of the augmented matrix eigen-sensitivity theories to TCSC siting problem for damping the inter-area low frequency oscillation in the large KEPCO system. First and second-order eigen-sensitivities of the inter-area low frequency oscillation in the large KEPCO system. First and second-order eigen-sensitivities of the inter-area mode are computed fro changes in susceptance of the transmission lines. The lines having high sensitivity are chosen as the initial candidates for installing TCSC. Then for each of the chosen candidates, Bodeplot of the transfer function with line susceptance as the input and the bus voltage at one side of the line as the output is computed. Using the Bode plots, the lines having any zeros near the inter-area mode are screened out since design of TCSC controller is very difficult in such a case. The $H_{\infty}$ TCSC controller installed at any finally chosen candidate is found to be effective in damping the inter-area oscillation, and the proposed TCSC siting algorithm is proved to be valid. Design of $H_{\infty}$ controller is described in Part IIof this paper.

  • PDF

Burke-Schumann analysis of silica formation by hydrolysis in an external chemical vapor deposition process (외부 화학증착 공정에서의 가수분해반응으로 인한 실리카 생성에 대한 버크-슈만 해석)

  • Song, Chang-Geol;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1671-1678
    • /
    • 1996
  • In external chemical vapor deposition processes including VAD and OVD the distribution of flame-synthesized silica particles is determined by heat and mass transfer limitations to particle formation. Combustion gas flow velocities are such that the particle diffusion time scale is longer than that of gas flow convection in the zone of particle formation. The consequence of these effects is that the particles formed tend to remain along straight smooth flow stream lines. Silica particles are formed due to oxidation and hydrolysis. In the hydrolysis, the particles are formed in diffuse bands and particle formation thus requires the diffusion of SiCl$\_$4/ toward CH$\_$4//O$\_$2/ combustion zone to react with H$\_$2/O diffusing away from these same zones on the torch face. The conversion kinetics of hydrolysis is fast compared to diffusion and the rate of conversion is thus diffusion-limited. In the language of combustion, the hydrolysis occurs as a Burke-Schumann process. In selected conditions, reaction zone shape and temperature distributions predicted by the Burke-Schumann analysis are introduced and compared with experimental data available. The calculated centerline temperatures inside the reaction zone agree well with the data, but the calculated values outside the reaction zone are a little higher than the data since the analysis does not consider diffusion in the axial direction and mixing of the combustion products with ambient air. The temperatures along the radial direction agree with the data near the centerline, but gradually diverge from the data as the distance is away from the centerline. This is caused by the convection in the radial direction, which is not considered in the analysis. Spatial distribution of silica particles are affected by convection and diffusion, resulting in a Gaussian form in the radial direction.

A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel (환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF

An Investigation of the Heat Loss Model for Predicting NO Concentration in the Downstream Region of Laminar CH4/Air Premixed Flames (층류 CH4/Air 예혼합화염의 하류영역에서 NO 농도 예측을 위한 열손실 모델의 검토)

  • Hwang, Cheol-Hong;Lee, Chang-Eon;Kum, Sung-Min;Lee, Kee-Man;Shin, Myung-Chul;Kim, Se-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.7
    • /
    • pp.486-494
    • /
    • 2009
  • One-dimensional modeling of $CH_4$/air premixed flame was conducted to validate the heat loss model and investigate NOx formation characteristics in the postflame region. The predicted temperature and NO concentration were compared to experimental data and previous heat loss model results using a constant gradient of temperature (100 K/cm). The following conclusions were drawn. In the heat loss model using steady-state heat transfer equation, the numerical results using the effective heat loss coefficient ($h_{eff}$) of $1.0\;W/m^2K$ were in very good agreement with the experiments in terms of temperature and NO concentration. On the other hand, the calculated values using the constant gradient of temperature (100 K/cm) were lower than that in the experiments. Although the effects of heat loss suppress NO production near the flame region, a significant difference in NO concentration was not found compared to that under adiabatic conditions. In the postflame region, however, there were considerable differences in NO emission index as well as the contribution of NO formation mechanisms. In particular, in the range of ${\phi}\;{\geq}\;0.8$, the prompt NO mechanism plays an important role in the NO reduction under the adiabatic condition. On the other hand, the mechanism contributes to the NO production under the heat loss conditions.

Smartphone Color-Code based Gate Security Control

  • Han, Sukyoung;Lee, Minwoo;Mariappan, Vinayagam;Lee, Junghoon;Lee, Seungyoun;Lee, Juyoung;Kim, Jintae;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.5 no.3
    • /
    • pp.66-71
    • /
    • 2016
  • Smart building gate security control system using smartphone integrated with near field communication (NFC) has become part of daily life usage these days. The technology change in replacing RF NFC device using visible light communication technology based approach growing faster in recent days. This paper propose a design and development of gate security control system using color code based user authentication ID generation as part of an intelligent access control system to control automatic door open and close. In this approach gate security access control use the recent visible light communication technology trends to transfer the user specific authentication code to door access control system using color code on smartphone screen. Using a camera in the door access control system (ACS), color codes on smartphone screens are detected and matched to the database of authenticated user to open the door automatically in gate security system. We measure the visual light communication technology efficiency as a part of the research and the experiments have revealed that more than 95% users authenticated correctly at the suggested experiment environment on gate security control system.