• Title/Summary/Keyword: near transfer

Search Result 875, Processing Time 0.029 seconds

Experimental study on nucleate boiling heat transfer enhancement using an electric field (전기장을 이용한 핵비등 열전달 촉진에 관한 실험적 연구)

  • Gwon, Yeong-Cheol;Kim, Mu-Hwan;Gang, In-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.12
    • /
    • pp.1563-1575
    • /
    • 1997
  • To understand EHD nucleate boiling heat transfer enhancement, EHD effects on R-113 nucleate boiling heat transfer in a non-uniform electric field were investigated. The pool boiling heat transfer and the dynamic behavior of bubbles in d.c./a.c. electric fields under a saturated or subcooled boiling were studied by using a plate-wire electrode and a high speed camera. From the pool boiling heat transfer study, the shift of the pool boiling curve, the increase of the heat transfer and the delay of ONB and CHF points to higher heat fluxes were observed. From the dynamic behavior of bubbles, it was observed that bubbles departed away from the whole surface of the heated wire in radial direction due to EHD effects by a nonuniform electric field. With increasing applied voltages, the bubble size decreased and the active nucleation site and the departure number of bubbles showed the different trend. The present study indicates that the EHD nucleate boiling heat transfer is closely connection with the dynamic behavior of bubbles and the secondary flow induced near the heated surface. Therefore, the basic studies on the bubble behavior such as bubble frequency, bubble diameter, bubble velocity and flow characteristics are necessary for complete understanding of the enhancement mechanism of the boiling heat transfer using an electric field.

NUMERICAL STUDY ON COMBINED HEAT TRANSFER IN NIR HEATING CHAMBER (근적외선 열풍기의 복합열전달에 관한 수치적 연구)

  • Choi, H.K.;Yoo, G.J.;Kim, I.H.
    • Journal of computational fluids engineering
    • /
    • v.12 no.4
    • /
    • pp.7-13
    • /
    • 2007
  • Numerical analysis is carried out for combined heat transfer in an indirected NIR(Near Infrared Ray) heating chamber. Reynolds number and shapes of absorbed cylinder are known as important parameters on the combined heat transfer effects. Reynolds number based on the outer diameter of the cylinder is varied from $10^3$ to $3{\times}10^5$. Four difference heat transfer regimes are observed: forced convection and radiative heat transfer on the outer surface of the cylinder, pure conduction in the cylinder body, pure natural convection and radiation between lamp surface and inner surface of the cylinder, and radiation from the lamp. Flow and temperature characteristics are presented with iso-contour lines for the absorbed circular and elliptic cylinders to compare their differences. The convective and radiative heat transfer fluxes are also compared with different Reynolds numbers. As usual, Reynolds number is an important factor to estimate increasing convective heat transfer as it increases. The shape of absorbed cylinder results overall heat transfer rates remain unchanged.

Factors influencing inter-hospital transfer time - A private ambulance - (병원 간 전원 시간에 영향을 미치는 요인 - 일개 사설이송단을 중심으로 -)

  • Kim, Seong-Ju
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1215-1223
    • /
    • 2019
  • Purpose: This study is to figure out not only the characteristics relating to transfer time of inter-hospital transfer patient which is transferred by a private ambulance, but also factors influencing the transfer time. Methods: In this study, an analysis of 750 patients with high severity levels among those transferred to another hospital by a private ambulance in Busan for whole year of 2017. Results: The results showed that the following factors significantly influence the total inter-hospital transfer time: Ambulance crew (${\beta}=10.525$, p=.001) and patient and carer (${\beta}=37.606$, p<.001) when setting a doctor (selecting a medical institution) as a criterion; availability of the specialized care (${\beta}=12.435$, p=.008) when setting the near distance (reason for selecting a hospital for transfer) as a criterion. The explanatory power of this analysis was R2=0.423, whereas the explanatory power of calibration was R2=0.411. Conclusions: Factors that increase the total inter-hospital transfer time were the ambulance crew, and patient and carer's selecting a medical institution, and the reason for selecting a hospital where enables to offer the specialized care services.

Numerical Study on the Performance and the Heat Flux of a Coaxial Cylindrical Steam Reformer for Hydrogen Production (수소 생산을 위한 동축원통형 수증기 개질기의 성능 및 열유속에 대한 수치해석 연구)

  • Park, Joon-Guen;Lee, Shin-Ku;Bae, Joong-Myeon;Kim, Myoung-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.9
    • /
    • pp.709-717
    • /
    • 2009
  • Heat transfer rate is a very important factor for the performance of a steam reformer because a steam reforming reaction is an endothermic reaction. Coaxial cylindrical reactor is the reactor design which can improve the heat transfer rate. Temperature, fuel conversion and heat flux in the coaxial cylindrical steam reformer are studied in this paper using numerical method under various operating conditions. Langmuir-Hinshelwood model and pseudo-homogeneous model are incorporated for the catalytic surface reaction. Dominant chemical reactions are assumed as a Steam Reforming (SR) reaction, a Water-Gas Shift (WGS) reaction, and a Direct Steam Reforming (DSR) reaction. Although coaxial cylindrical steam reformer uses 33% less amount of catalyst than cylindrical steam reformer, its fuel conversion is increased 10 % more and its temperature is also high as about 30 degree. There is no heat transfer limitation near the inlet area at coaxial-type reactor. However, pressure drop of the coaxial cylindrical reactor is 10 times higher than that of cylindrical reactor. Operating parameters of coaxial cylindrical steam reformer are the wall temperature, the inlet temperature, and the Gas Hourly Space Velocity (GHSV). When the wall temperature is high, the temperature and the fuel conversion are increased due to the high heat transfer rate. The fuel conversion rate is increased with the high inlet temperature. However, temperature drop clearly occurs near the inlet area since an endothermic reaction is active due to the high inlet temperature. When GHSV is increased, the fuel conversion is decreased because of the heat transfer limitation and short residence time.

Nuclear and Microtubule Reorganization in Cattle Nuclear Transfered Embryos

  • Shin, Mi-Ra;Park, Sang-Wook;Cui, Xiang-Shun;Shim, Ho-Sup;Kim, Nam-Hyung
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.18-18
    • /
    • 2001
  • Despite of importance of integrated events of nucleus and microtubule remodeling in nuclear transferred embryos with somatic cells, little information is available on this subject. In this study we configured chromatin and microtubule organization following somatic cell nuclear transfer in pre- and non-activated bovine oocytes in order to clearify nuclear remodeling process and to demonstrate centrosome inheritance during nuclear transfer. The cumulus-oocyte complexes were collected from slaughterhouse and were matured in vitro for 20 h in TCM 199 supplemented hormone. Matured bovine oocytes were enucleated by aspirating the frist polar body and metaphase chromatin using a beveled pipette. Bovine fibroblast cells were fused into enucleated oocyte by electrical stimulation. Reconstructed oocytes were activated with ionomycine and 6-dimethylaminopurin, and then cultured in CRlaa medium. The organization of nuclear and microtubules were observed using laser-scanning confocal microscopy. At 1 hour after fusion, microtubule aster was seen near the transferred nucleus in most oocytes regardless activation condition. While most of fibroblast nuclei remodeled to premature chromosome condensation (PCC) and to the two masses of chromosome in non-activated oocytes, a few number of fibloblasts went to PCC and multiple pronuclear like structures in activated oocytes. Microtubular spindle was seen around condensed chromosome. Gamma-tubulin was detected in the vicinity of condensed chromosome, suggesting this is a transient spindle. The spindle seperated nucleus into two masses of chromatin which developed to the pronuclear like structures. Two pronuclear like structures were than apposed by microtubular aster and formed one syngamy like nuclear structure at 15 h following nuclear transfer. At 17 to 18 h after fusion, two centrosomes were seen near the nucleus, which nucleates micrtubules for two cell cleavage. While 31% of reconstructed oocytes in non-activated condition developed to morulae and blastocysts, a few reconstructed oocytes in pre-activated condition developed to the blastocyst. These results suggested introduction of foreign centrosome during nuclear transfer, which appeared to give an important role for somatic cell nuclear reprogramming.

  • PDF

A Study on the Radiation Heat Transfer Effect near a Refrigerator Gasket (냉장고 가스켓 주위의 복사열전달 효과에 관한 연구)

  • Ha, Ji-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1605-1610
    • /
    • 2015
  • The present study has been accomplished to elucidate the effect of radiation heat transfer in the heat transfer analysis of refrigerator gasket, which has near 30% of refrigerator heat loss. The numerical heat transfer analysis has been conducted with the simplified modeling of refrigerator gasket. From the present CFD analysis, heat loss at the gasket is $25.6W/m^2$ for the case without radiation effect and that for the case with radiation effect is $55.0W/m^2$, which is 2.2 times greater heat loss. The radiation protection layers were installed in the gasket from 0 to 7 and the case with 7 layers has 33% reduction effect of heat loss compared with the case without any radiation protection layer. Additionally, it is better effect of radiation heat loss reduction that the radiation protection layers would be placed to the outer or inner side of gasket rather than placing to the center of gasket.

Novel Erbium(III)-Encapsulated Complexes Based on ${\pi}$-Extended Anthracene Ligands Bearing G3-Aryl-Ether Dendron: Synthesis and Photophysical Studies

  • Baek, Nam-Seob;Kim, Yong-Hee;Roh, Soo-Gyun;Lee, Dong-Hyun;Seo, Kang-Deuk;Kim, Hwan-Kyu
    • Macromolecular Research
    • /
    • v.17 no.9
    • /
    • pp.672-681
    • /
    • 2009
  • A series of inert and photo-stable Er(III)-encapsulated complexes based on ${\pi}$-extended dendritic anthracene ligands bearing G3-aryl-ether dendron ([G3-AnX]-$CO_2H$), which retain different ${\pi}$-bridging systems, such as single (X= S), double (X= D) and triple (X= T) bonds was designed and synthesized to establish the structure-property relationship. The near infrared emission intensities of Er(III)-encapsulated complexes were enhanced dramatically by increasing the ${\pi}$-conjugated extension of anthracene ligands. The time-resolved luminescence spectra show monoexponential decays with a lifetime of $2.0{\sim}2.4ms$ for $Er^{3+}$ ions in thin films, and calculated intrinsic quantum yields of $Er^{3+}$ ions are in the range of $0.025{\sim}0.03%$. As a result, all Er(III)-encapsulated dendrimer complexes exhibit the near IR emission with the following order: $Er^{3+}-[G3-AnD]_3$(terpy) > $Er^{3+}-[G3-AnS]_3$(terpy) ${\approx}$ $Er^{3+}-[G3-AnT]_3$(terpy), because $Er^{3+}-[G3-AnD]_3$(terpy) has a higher relatively spectral overlap J value and energy transfer efficiency. In addition, the lack of detectable phosphorescence and no significant spectral dependence of the ${\pi}$-extended anthracene moieties on the solvent polarity support energy transfer from their singlet state to the central $Er^{3+}$ ion taking place in $Er^{3+}-[G3-AnX]_3$(terpy).

A Comparison of Standardization Methods in Near-infrared Analysis

  • Ko, Young-Hyun;Park, Kwang-Su;Lee, Hye-Seon;Jun, Chi-Hyuck;Ku, Min-Sik;Chung, Hoe-Il
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.9-17
    • /
    • 2000
  • A variety of standardization methods between two near-infrared (NIR) spectrometers were investigated for the prediction of five constituents in trans-alkylation process. Spectra were collected by two different instruments (one is regarded as mater instrument, other on as slave instrument). Three well-known standardization methods of direct standardization (DS), piecewise direct standardization (PDS) and slope/bias correction of response variable were applied to trans-alkylation samples on the slave instrument. We have examined for a set of reliable standardization samples using smaller number of transfer samples in order to increase efficiency of standardization.