• 제목/요약/키워드: natural tracer

검색결과 70건 처리시간 0.025초

Identifying N sources that affect N uptake and assimilation in Vanda hybrid using 15N tracers

  • Panjama, Kanokwan;Ohyama, Takuji;Ohtake, Norikuni;Sato, Takashi;Potapohn, Nuttha;Sueyoshi, Kuni;Ruamrungsri, Soraya
    • Horticulture, Environment, and Biotechnology : HEB
    • /
    • 제59권6호
    • /
    • pp.805-813
    • /
    • 2018
  • Vanda is an aerial tropical orchid native to Thailand and nitrogen (N) fertilizer is mainly used to promote its growth and quality. However, little is known about the characteristics of N absorption and assimilation in Vanda. The objective of this study was to determine the appropriate source of N for Vanda cultivation. In this experiment, shoots and roots of Vanda 'Ratchaburi Fuchs-Katsura' were sprayed weekly with 100 ml of $^{15}N$ tracer solution (1) 10 mM of $^{15}NO_3{^-}$, (2) 5 mM of $^{15}NO_3{^-}$ plus 5 mM of $NH_4{^+}$, (3) 5 mM of $NO_3{^-}$ plus 5 mM of $^{15}NH_4{^+}$ and (4) 10 mM of $^{15}NH_4{^+}$. The results indicated that plants fed with a combined N fertilizer gave the highest of $^{15}N$ use efficiency ( $^{15}NUE$) of about 21.8%, 30 days after the first feeding (DAF), compared with those fed sole sources of $^{15}NO_3{^-}$ (21.0%) and $^{15}NH_4{^+}$ (16.6%). However, a sole nitrate fertilizer or combination fertilizer did not significantly affect the total N and labelled N content. Alanine was a major amino acid found in leaves and roots at 7 DAF, whereas glutamine was mainly found in stems. At 30 DAF, tyrosine and alanine became major components in the leaves, and glutamine decreased in stems when plants were fed with a single $^{15}NH_4{^+}$ source.

연안환경에서 유기물 지표 개발을 위한 가능성 평가: 용존유기탄소와 형광용존유기물질 활용 (Evaluation of the Possibility of Developing Organic Matter Indicators in Coastal Environments: Utilization of Dissolved Organic Carbon and Fluorescent Dissolved Organic Matter)

  • 이민영;양경선;김순찬;김태훈
    • Ocean and Polar Research
    • /
    • 제43권2호
    • /
    • pp.65-72
    • /
    • 2021
  • In order to evaluate the dissolved organic carbon (DOC) and fluorescent dissolved organic matter (FDOM), as indicators of organic matter in the coastal environments, we measured the concentrations of DOC, FDOM, and chemical oxygen demand (COD) in saline groundwater (Woljeong, Pyoseon, and Hwasun beaches) and coastal seawater (Haengwon, Gwideok, Pyoseon, and Yeongnak) in Jeju, Korea. The highest concentrations of DOC and COD in groundwater were found in Woljeong and Pyoseon, and those in coastal water were observed in Haengwon and Pyoseon, indicating that the higher concentrations of DOC and COD seem to be associated with saline groundwater-driven dissolved organic matter (DOM) and/or biogeochemical processes. According to origin and optical properties of DOM using FDOM as a tracer, proportion of humic-like FDOM, more refractory DOM, was relatively greater in the groundwater than in the coastal water. With regard to this result, there was no relationship between DOC and COD in groundwater, while DOC showed a good positive correlation (r2 = 0.66) with COD in coastal water. This result indicates that COD as an indicator of assessment of DOM has a limitation in which it is difficult to quantify refractory DOM. Although DOC is a potential alternative to COD in the coastal environments, particulate organic carbon cannot be negligible due to relatively higher concentration compared to the open ocean. Therefore, the use of total organic carbon (TOC) as a replacement of COD in the coastal ocean is important, and the evaluation criterion of the TOC is necessary in order to evaluate of organic matter indicator in the various coastal environments.

입자추적방법을 이용한 다중저장대모형 개발 (Development of Multiple Transient Storage Model Using Particle Tracking Method)

  • 정태성;서일원
    • 한국수자원학회논문집
    • /
    • 제37권4호
    • /
    • pp.257-271
    • /
    • 2004
  • 본류대를 따라 저장대가 주기적으로 존재하는 다중저장대모형을 개발하고 자연하천의 혼합거동을 해석하였다. 개발된 모형 및 하나의 저장대를 갖는 기존의 저장대모형을 비교하기 위하여 모형실험 결과를 이용하였다. 본 모형을 이용하여 구한 농도분포는 모형실험에서 수집된 시간에 따른 농도분포를 잘 재현하는 반면, 연속적인 저장대를 갖는 기존모형은 불연속적인 저장대 구조로 인해 발생하는 농도분포의 부차적인 융기부분을 정확히 재현하지 못하는 것으로 나타났다. 본 모형의 현장 적용성을 검토하기 위하여 새로운 모형을 미국 미네소타주에 위치한 Shingobee River에 적용하고 혼합거동을 해석한 결과 새로운 저장대 모형은 저장대가 존재하는 자연하천에서의 분산거동을 정확하게 모의하는 것으로 나타났다.

지하수 조사에서 환경추적자로서의 $SF_6$의 적용

  • 고동찬;;;김용제
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 총회 및 춘계학술발표회
    • /
    • pp.73-76
    • /
    • 2003
  • SF$_{6}$ (Sulfur Hexafluoride) is a gaseous compound whose use is being greatly increased recently. The compound has a negligible background concentration from natural sources and is stable in most of groundwater environments. Therefore, SF$_{6}$ has potential for a dating tool for young groundwater. It has many advantages over chlorofluorocarbons (CFCs) for groundwater investigation that sampling procedure is much simpler than CFCs and its growth is continued up to at least near future in the atmosphere. However, solubility of SF$^{6}$ is so low that excess air causes large uncertainties in recharge date of groundwater. To compensate the limitation, $N_2$/Ar method can be employed to estimate excess air content. A groundwater study is currently carrying out in Jeju Island using SF$_{6}$ as an environmental tracer, Well waters and spring waters were sampled for SF$_{6}$ and $N_2$/Ar. To establish SF$_{6}$ input history in the study area, air sampling is being conducted in the area near the center of the island on a monthly and weekly basis. Based on the present data, the level of SF$_{6}$ concentration in the atmosphere of the Island is corresponding to the trend of the Northern Hemisphere.

  • PDF

MODELING OF A BUOYANCY-DRIVEN FLOW EXPERIMENT IN PRESSURIZED WATER REACTORS USING CFD-METHODS

  • Hohne, Thomas;Kliem, Soren
    • Nuclear Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.327-336
    • /
    • 2007
  • The influence of density differences on the mixing of the primary loop inventory and the Emergency Core Cooling (ECC) water in the downcomer of a Pressurised Water Reactor (PWR) was analyzed at the ROssendorf COolant Mixing (ROCOM) test facility. ROCOM is a 1:5 scaled model of a German PWR, and has been designed for coolant mixing studies. It is equipped with advanced instrumentation, which delivers high-resolution information for temperature or boron concentration fields. This paper presents a ROCOM experiment in which water with higher density was injected into a cold leg of the reactor model. Wire-mesh sensors measuring the tracer concentration were installed in the cold leg and upper and lower part of the downcomer. The experiment was run with 5% of the design flow rate in one loop and 10% density difference between the ECC and loop water especially for the validation of the Computational Fluid Dynamics (CFD) software ANSYS CFX. A mesh with two million control volumes was used for the calculations. The effects of turbulence on the mean flow were modelled with a Reynolds stress turbulence model. The results of the experiment and of the numerical calculations show that mixing is dominated by buoyancy effects: At higher mass flow rates (close to nominal conditions) the injected slug propagates in the circumferential direction around the core barrel. Buoyancy effects reduce this circumferential propagation. Therefore, density effects play an important role during natural convection with ECC injection in PWRs. ANSYS CFX was able to predict the observed flow patterns and mixing phenomena quite well.

비정상 자연대류에 의한 온도성층화의 동특성에 관한 연구 (Dynamic Characteristics of Thermal Stratification Build-up by Unsteady Natural Convection)

  • 강보선;이준식;이택식;노승탁
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.382-394
    • /
    • 1988
  • Dynamic characteristics of thermally-forced stratification process in a square enclosure with a linear temperature profile at the side walls have been investigated through flow visualization experiment and numerical analysis. The experiment was performed on air with the Rayleigh numbers of order $10^5$. A particle tracer method is used for the flow visualization and to obtain a sudden linear temperature profile at the side walls copper blocks which already have a linear temperature profile are come into contact with the thin copper plates of the test section. Immediately a meridional circulation is developed and heat transfer takes place from the wall to the interior region by circulation of fluid and finally a thermal stratification is achieved. In the numerical study, QUICK scheme for convective terms, SIMPLE algorithm for pressure correction, and the implicit method for the time marching are adopted for the integration of conservation equations. Comparison of flow visualization and numerical results shows that the developing flow patterns are very similar in dynamic nature even though there is a time lag due to the inevitable time delay in setting up a linear temperature profile. For high Rayleigh numbers, the oscillatory motion is likely to take place and stratified region is extended. However, initial temperature adjustment process is much slower than that for low Rayleigh numbers.

  • PDF

Application of radiotracer technique in remediation of Zn(II) from aqueous solutions by dry cowdung powder

  • Shaikh, Sabrina Afzal;Bagla, Hemlata Kapil
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.456-461
    • /
    • 2022
  • Heavy metal pollution is caused due to anthropogenic activities and is considered as a serious environmental problem which endangers human health and environment. The present study deals with biosorption, an eco-friendly technique for the removal of heavy metal Zn(II) from aqueous medium. Various natural materials have been explored for the uptake of metal ions, where most of them are physically or chemically enhanced. Dry cowdung powder (DCP) has been utilized as a low-cost, environmentally friendly humiresin without any pre-treatment, thus demonstrating the concept of Green Chemistry. Batch biosorption studies using 65Zn(II) tracer were performed and the impact of different experimental parameters was studied. Results revealed that at pH 6, 94 ± 2% of Zn(II) was effectively biosorbed in 5 min, at 303 K. The process was spontaneous and exothermic, following pseudo-second-order reaction. The mechanism of heavy metal biosorption employing green adsorbent was therefore elucidated in order to determine the optimal method for removing Zn(II) ions. DCP has a lot of potential in the wastewater treatment industry, as seen by its ability to meet 3A's affordability, adaptability, and acceptability criteria. As a result, DCP emerges as one of the most promising challengers for green chemistry and the zero-waste idea.

난류특성을 이용한 대기오염확산모델의 예측능에 관한 연구 (A Study on the Predictability of the Air Pollution Dispersion Model Composed of the Turbulent Parameters)

  • 박기학;윤순창
    • 환경영향평가
    • /
    • 제10권2호
    • /
    • pp.123-133
    • /
    • 2001
  • Gaussian dispersion model is the most widely used tool for the ground level air pollution simulation. Though in spite of the convenience there are important problems on the Pasquill- Gifford' stability classification scheme which was used to define the turbulent state of the atmosphere or to describe the dispersion capabilities of the atmosphere which was each covers a broad range of stability conditions, and that they were very site specific, and the vertical dispersion calculation formula on the case of the unstable atmospheric condition. This paper was carried out to revise the Gaussian dispension model for the purposed of increase the modeling performance and propose the revised model, which was composed of the turbulent characteristics in the unstable atmospheric conditions. The proposed models in this study were composed of the profile method, Monin-Obukhove length, the probability density function model and the lateral dispersion function which was composed of the turbulent parameters, $u_*$(friction velocity), $w_*$(convective velocity scale), $T_L$(lagrangian time scale) for the model specific. There were very good performance results compare with the tracer experiment result on the case of the short distance (<1415m) from the source, but increase the simulation error(%) to stand off the source in the all models. In conclusion, the revised Gaussian dispersion model using the turbulent characteristics may be a good contribution for the development of the air pollution simulation model.

  • PDF

사행하천에서 오염물질의 2차원 거동특성 해석 (Analysis of Two-Dimensional Pollutant Transport in Meandering Streams)

  • 오정선;서일원;김영한
    • 한국수자원학회논문집
    • /
    • 제37권12호
    • /
    • pp.979-991
    • /
    • 2004
  • 본 연구에서는 사행하는 자연하천에 유입된 오염물질의 2차원 확산 특성을 모의하기 위하여 2차원 수심적분 모형인 RMA2와 RMA4를 사용하였다. 먼저 2차원 동수역학적인 모형인 RMA2를 사용하여 흐름장을 모의한 후 이 결과를 2차원 수질모형인 RMA4에 입력하여 농도장을 모의하였다. 수치모형을 S자형 사행수로에서 측정한 흐름 및 추적자 농도자료를 이용하여 검증한 결과, RMA4 모형은 최대유속선이 만곡의 내측에 치우쳐 나타나는 현상을 잘 모의하고 있었으며, RMA4 모형은 오염운의 전반적인 확산 특성과 분리 현상을 적절하게 모의하고 있었다. 수치모형을 실제 하천에 적용하여 현장 실험 결과를 비교한 결과, RMA2 모형은 전체적인 흐름 특성 및 만곡의 외측 제방으로 치우치는 최대유속선의 경향 등을 잘 모의하였으며, RMA4모형은 오염운이 최대유속선을 따라 이동하는 경향 등을 적절하게 재현하는 것으로 밝혀졌다. 본 연구에서 분산계수는 실측 농도분포로부터 계산한 값을 미세 조정하여 사용하였으며, 이는 기존의 추정식에 의한 추정치와도 잘 부합하는 것으로 밝혀졌다.

전산유체역학을 이용한 표준 오리사 설계안에 대한 환기효율성 분석 (Analysis on Ventilation Efficiency of Standard Duck House using Computational Fluid Dynamics)

  • 여욱현;조예슬;권경석;하태환;박세준;김락우;이상연;이승노;이인복;서일환
    • 한국농공학회논문집
    • /
    • 제57권5호
    • /
    • pp.51-60
    • /
    • 2015
  • In Korea, 69.4 % of duck farms had utilized conventional plastic greenhouses. In this facilities, there are difficulties in controlling indoor environments for raising duck. High rearing density in duct farms also made the environmental control difficult resulting in getting more stressed making their immune system weaker. Therefore, a facility is needed to having structurally enough solidity and high efficiency on the environmental control. So, new design plans of duck house have recently been conducted by National Institute of Animal Science in Korea. As a study in advance to establish standard, computational fluid dynamics (CFD) was used to estimate the aerodynamic problems according to the designs by means of overall and regional ventilation efficiencies quantitatively and qualitatively. Tracer gas decay (TGD) method was used to calculate ventilation rate according to the structural characteristics of duck houses including installation of indoor circulation fan. The results showed that natural ventilation rate was averagely 164 % higher than typically designed ventilation rate, 1 AER ($min^{-1}$). Meanwhile, mechanically ventilated duck houses made 81.2 % of summer ventilation rate requirement. Therefore, it is urgent to develop a new duck house considering more structural safety as well as higher efficiency of environmental control.