A Numerical Study for the Performance of Natural Smoke-venting of a Vertical Vent (수직 배연구의 자연배연 성능에 관한 수치해석연구)

  • Jeon, Heung-Kyun;Choi, Young-Sang;Choo, Hong-Lok
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.1-10
    • /
    • 2008
  • In this study, the effects of vent location, outside temperature, wind velocity and fire size on the performance of natural venting of the vertical vent designed according to NFPA 204 standard and fire characteristics were numerically investigated using CFAST. In cases of the Vent located on most upper wall, lower outside temperature and lower wind velocity, vents met the performance criteria of venting. The larger fire size becomes, the more mass flow rate through a vent becomes, but the lower interface height of smoke layer becomes, so that vent didn't meet the performance criteria of venting. It should be noted that a natural vertical vent be designed considering maximum outside temperature and maximum wind velocity and developing a design fire accurately in order to meet the performance criteria of venting.

A Study on the Effectiveness to the Life Safety by Enlarging Smoke Vent Size and/or Sprinklered System (배연창 크기와 스프링클러 작동이 인명안전에 미치는 영향 연구)

  • Kim, Hak-Joong;Park, Yong-Hwan;Lim, Choe-Hyun;Kim, Bum-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.133-138
    • /
    • 2010
  • Recently, evacuation safety of a resident of building become the major concern, because building has been higher and more complicated. Buildings in Korea should install the natural smoke venting or mechanical smoke exhaust equipment according to the building law. The smoke control is the most important to guarantee the evacuation safety. This study evaluate the influence to the height and temperature of smoke layer by enlarging smoke vent size and operating sprinkler system using CFAST (Version 6). Smoke venting size is larger, the effect to height and temperature of smoke layer is increased in below 5 MW fire. But, the correlation of these is decreased in above 10 MW fire. The case that opened smoke vent and sprinklered are applied, life safety criteria are satisfied regardless of fire size. After design the fire scenario according to the service and size of building. Install the smoke vent suitable for the fire size and verify that by experiment or simulation.

A Study on the Comparison of Natural Ventilation Standards for Domestic and Foreign Logistics Warehouses (국내외 물류창고의 자연배연기준 비교에 관한 연구)

  • Kim, Yun-Seong;Choi, Yun-Ju;Huh, Ye-Rim;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.67-68
    • /
    • 2022
  • Foreign countries stipulate that ventilation and smoke control facilities are installed in logistics warehouses. On the other hand, in Korea, the design guidelines and standards of ventilation and smoke control facilities for logistics warehouses are not clear even in the situation where the number of human casualties caused by smoke has increased until recently. Accordingly, the smoke descent time according to the vent was calculated. As a result, when there was no vent, the smoke descent time was 369s. On the other hand, when the vent was installed, smoke did not fall because the amount of smoke was greater than the amount of smoke generated.