• Title/Summary/Keyword: natural refrigerant $CO_2$

Search Result 24, Processing Time 0.022 seconds

Development of a High Efficient LNG Refrigerated Truck using Natural Refrigerant CO2 (자연냉매 CO2를 이용한 고효율 LNG 냉동 트럭의 개발)

  • Jeong, Se Jin;Kwak, Hun Sub;Min, Ho Ki
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.77-82
    • /
    • 2020
  • In this paper, we developed a cooling system for the refrigeration truck using natural carbon dioxide refrigerant which is attracting attention as an environmentally-friendly refrigerant. We developed a high efficient environmentally-friendly refrigerated truck that converted the existing diesel vehicle into an LNG vehicle to improve emissions of truck and improved the efficiency of the cooling system by utilizing a heat of LNG vaporization. The COP of refrigerated truck system was increased 144%.

Friction and Wear of the Scroll Compressor Sliding Surfaces in the Natural Refrigerant $CO_2$ Environment (자연냉매 $CO_2$환경에서 스크롤 압축기 구동부의 마찰 마멸특성 평가)

  • 오세두;문재용;조성욱;이인주;김철우;이영제
    • Tribology and Lubricants
    • /
    • v.19 no.3
    • /
    • pp.146-150
    • /
    • 2003
  • The natural refrigerant $CO_2$has attracted as an alternative refrigerant currently used in air conditioning system, which has high global warming potential. In this study, the tribological characteristics of the sliding surfaces between a fixed scroll and an orbiting scroll of the scroll compressor were investigated in $CO_2$/ POE mixed environment. The pin-on-disk type sliding tests were carried out under the various sliding speeds, normal loads. surface roughness, and pressures. During the test, friction forces, wear amount and surface temperature were monitored.

The Flow Characteristics of Pressure Control Valves for Natural Refrigerants (천연 냉매용 압력제어밸브의 유동특성 평가)

  • Kang, Hyo-Lim;Park, Hyung-Joon;Kim, Ga-Eun;Han, Seung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.3
    • /
    • pp.51-56
    • /
    • 2020
  • Research into natural refrigerants that use CO2, instead of chlorofluorocarbons and hydrofluorocarbons, has increased due to the environmental problems caused by ozone depletion. CO2 refrigerants are more environmentally friendly than conventional refrigerants because they have better latent heat of evaporation and heat transfer efficiency properties. However, they have very low critical temperatures and require high design pressures; therefore, pressure control valves, which reduce the pressure of the CO2 refrigerant to a safe level and apply it to the refrigerant air conditioning system, are necessary to secure stability against high pressure. In the present study, we evaluated the flow characteristics and valve performance of the pressure control valve using a CO2 refrigerant by measuring the pressure, velocity, and flow coefficient. In addition, we examined the applied forces caused by the internal pressure from the highly pressurized CO2 refrigerant and required thrust characteristics.

Performance Analysis of the Swash Plate Type Compressor using CO2 Refrigerant (CO2용 사판식 압축기 성능 해석)

  • Lee, Geon-Ho;Park, Ik-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.564-569
    • /
    • 2005
  • Recently, from the viewpoint of global wanning, natural gas CO2 is considered as a main refrigerant for hot water system. The characteristics of CO2 is not toxic, not flammable, high pressure, and high refrigerating capacity. Also it is widely available as a byproduct of industrial processes. This paper describes the performance analysis program of the swash plate type compressor using CO2 refrigerant. Estimates of the refrigerant flow rate, compression work, discharge temperature and volumetric, compressor efficiencies of the CO2 swash plate type compressor are obtained from the various design parameter such as the inclination angle of the swash plate, discharge hole area and suction hole area.

  • PDF

Performance Evaluation of $CO_2$ Air-Conditioning System (이산화탄소를 사용하는 냉동 시스템의 성능 평가 (I))

  • 신지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.2
    • /
    • pp.24-30
    • /
    • 2000
  • The high-pressure natural refrigerant $CO_2$ is now being evaluated for use in the motor vehicle air-conditioning systems and for several types of unitary equipment. In this study thermodynamic properties of $CO_2$ is compared to those of R-22 and R-134a and the performance characteristics of $CO_2$ refrigeration cycle is analyzed. The results show that the optimum discharge pressure for the cycle performance exists. New design concept for the $CO_2$ refrigeration system should be developed due to the high-operating pressure of itself.

  • PDF

A Study of Development of Regrigerated Truck Small Scale Cooling System and Key-Part using Natural Refrigerants. (자연냉매인 CO2를 이용한 냉동탑차 냉장시스템과 핵심부품개발에 관한 연구)

  • Jeong, Se Jin;Park, Seong Sin;Min, Ho Ki;Jo, Ga Yeong
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.1
    • /
    • pp.19-26
    • /
    • 2019
  • In this study, we developed a cooling system for 1 ton size refrigeration vehicle using carbon dioxide natural refrigerant among hydrocarbon type refrigerant which is attracting attention as environment friendly refrigerant, and designed a heat exchanger and a unit cooler to raise COP. In addition, existing CNG 5 ton refrigerated trucks were converted into LNG vehicles to increase the efficiency of the cooling system and ensure safety against CNG. As a result, environmentally friendly refrigerated trucks using natural refrigerants of 1 ton and 5 ton sizes were developed.

Study on the Evaporation Heat transfer of $CO_2$ in a Horizontal tube (수평관내의 $CO_2$의 증발 열전달에 관한 연구)

  • Jang, Seong-Il;Choi, Sun-Muk;Kim, Dae-Hui;Oh, Hoo-kyu
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.240-241
    • /
    • 2005
  • The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 4.57 mm, and length of 4 m. The experiments were conducted at mass flux of 200 to 700 kg/$m^2s$, saturation temperature of 0$^{circ}C$ to 20$^{circ}C$, and heat flux of 10 to 30 kW/$m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with test results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

Numerical Study on the Evaporation Flow Phenomena of Natural Refrigerant CO2 through Small Diameter Tubes (천연냉매인 이산화탄소의 세관 유동시 발생하는 증발 유동 현상에 대한 수치해석 연구)

  • Choi, In-Su;Park, Byung-Duck
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • For the environment protection, carbon dioxide as a natural refrigerant has been studied to use in an automotive air conditioning system. Hence, a numerical model has been developed to describe the evaporation phenomena of carbon dioxide flowing through very small diameter tubes. The two dimensional low-Reynolds $k-{\varepsilon}$ model was used to predict the flow phenomena of carbon dioxide in the two phase during its evaporation. Furthermore, the results obtained from the model were compared with the experiments for the validation. The heat transfer coefficient is lower, as the tube inner diameter becomes smaller. However, the amount of heat absorbed by a unit mass of carbon dioxide is greater due to more surface area. Therefore, the small diameter tube has advantage in terms of compact design of evaporator. When the inlet condition of pressure and temperature is low, the heat transfer coefficient is slightly high at the same size of tube because of the thermal properties of carbon dioxide.

  • PDF

Evaporation Heat Transfer of Carbon Dioxide in a horizontal Round Tube (수평원관내 $CO_2$의 증발열전달)

  • Kyoung, Nam-Soo;Jang, Seung-Il;Choi, Sun-Muk;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.262-267
    • /
    • 2005
  • The evaporation heat transfer coefficient of $CO_2$ in a horizontal round tube was investigated experimentally. The experiments were conducted without oil in a closed refrigerant loop which was driven by a magnetic gear pump. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and evaporator(test section). The test section was made of a horizontal stainless steel tube with the inner diameter of 7.75 mm, and length of 5 m. The experiments were conducted at mass flux of 200 to 500 $kg/m^2s$, saturation temperature of $-5^{\circ}C$ to $5^{\circ}C$, and heat flux of 10 to 40 $kW/m^2$. The test results showed the evaporation heat transfer of $CO_2$ has great effect on more nucleate boiling than convective boiling. The evaporation heat transfer coefficients of $CO_2$ are highly dependent on the vapor quality, heat flux and saturation temperature. In comparison with teat results and existing correlations, correlations failed to predict the evaporation heat transfer coefficient of $CO_2$, therefore, it is necessary to develop reliable and accurate predictions determining the evaporation heat transfer coefficient of $CO_2$ in a horizontal tube.

  • PDF

An Experimental Study on Heat Transfer and Pressure Drop Characteristics of Carbon Dioxide During Gas Cooling Process in a Hellically Coiled Tube

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Yu, Tae-Geun;Kim, Dae-Hui
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.263-271
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during 9as cooling process of $CO_2$ (R744) in a helically coiled copper tube with the inner diameter of 4.55 mm and outer diameter of 6.35 mm were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump. a mass flow meter a pre-heater and a helically coiled type gas cooler (test section). The refrigerant mass fluxes are varied from 200 to $800kg/m^2s$ and the inlet pressures of gas cooler are 7.5 to 10.0 MPa. The heat transfer coefficients of $CO_2$ in a helically coiled tube are higher than those in a horizontal tube. The Pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those predicted by Ito's correlation developed for single-phase in a helically coiled tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However. at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al correlation. Therefore, various experiments in helically coiled tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in a helically coiled tube.