• Title/Summary/Keyword: natural head Position

Search Result 62, Processing Time 0.026 seconds

Sensitivity Studies on Thermal Margin of Reactor Vessel Lower Head During a Core Melt Accident

  • Kim, Chan-Soo;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.379-394
    • /
    • 2000
  • As an in-vessel retention (IVR) design concept in coping with a severe accident in the nuclear power plant during which time a considerable amount of core material may melt, external cooling of the reactor vessel has been suggested to protect the lower head from overheating due to relocated material from the core. The efficiency of the ex-vessel management may be estimated by the thermal margin defined as the ratio of the critical heat flux (CHF)to the actual heat flux from the reactor vessel. Principal factors affecting the thermal margin calculation are the amount of heat to be transferred downward from the molten pool, variation of heat flux with the angular position, and the amount of removable heat by external cooling In this paper a thorough literature survey is made and relevant models and correlations are critically reviewed and applied in terms of their capabilities and uncertainties in estimating the thermal margin to potential failure of the vessel on account of the CHF Results of the thermal margin calculation are statistically treated and the associated uncertainties are quantitatively evaluated to shed light on the issues requiring further attention and study in the near term. Our results indicated a higher thermal margin at the bottom than at the top of the vessel accounting for the natural convection within the hemispherical molten debris pool in the lower plenum. The information obtained from this study will serve as the backbone in identifying the maximum heat removal capability and limitations of the IVR technology called the Cerium Attack Syndrome Immunization Structures (COASISO) being developed for next generation reactors.

  • PDF

Dynamic characteristic analysis of SMT mounter system (SMT 마운터의 동특성 분석)

  • Rim, Kyung-Hwa;Jung, Jin-Ho;Beom, Hee-Rak
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.440-445
    • /
    • 2011
  • Dynamic characteristic analysis is required in developing SMT mounter system with high installation speed and position precision, because of vibration source occurred by positioning head. This paper presents the method of improving dynamic characteristic of SMT(Surface Mount Technology) mounter with finite element method and modal test. The design direction is that natural frequencies of SMT mounter must be higher than the vibration source. In addition, the effect of input shaping on residual vibration reduction is investigated by simulating the response of a first-order system.

  • PDF

Taxonomic Study of Marine Tardigrades from Korea II. Genus Halechiniscus (Heterotardigrada, Arthrotardigrada, Halechiniscidae) (한국산 해양 완보류의 분류학적 연구 II. 바다가시곰벌레속 (이완보강. 마디곰벌레목. 바다가시곰벌레과))

  • Chang, Cheon-Young;Park, Hyun-Soo
    • Animal Systematics, Evolution and Diversity
    • /
    • v.18 no.1
    • /
    • pp.91-98
    • /
    • 2002
  • Two marine tardigrades belonging to the genus Halechiniscus Richters, H. jejuensis n. sp. and H. remanei Schulz are recorded from Jeju Island, Korea. Halechiniscus jejuensis n. sp. is distinguished from the congeners by the shape and position of lateral body processes, the shape of sensory papilla on leg IV, and the contour of head portion not clearly divided into two lobes. A revised key to the nine species of the genus Halechiniscus is prepared.

Soft tissue cephalometric analysis of Aesthetic Korean female (심미적 측모에 관한 두부계측방사선학적 연구)

  • Kim, Yoon-Ji;Nahm, Dong-Seok
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.383-393
    • /
    • 2002
  • The purpose of this study was to provide data on the normative values of some clinically important soft tissue dimensions for adult Korean females with aesthetically beautiful facial profiles. Lateral cephalograms of 18 Korean female models, who were selected for their well balanced and aesthetic facial profiles, were evaluated. All cephalograms were taken with the subjects in a natural head position with the teeth in occlusion and the lips at rest. The means and standard deviations were determined and presented. In addition, comparisons with the previous studies were performed The results of the present study were as follows: 1. The upper and lower lips were posteriorly located in relation to the Ricketts' E line (Upper lip to E line: -2.08, Lower lip to E line: -0.04). 2. Both lips were more posteriorly located than those in the results of previous studies on Korean females selected by normal occlusion, but more anteriorly located than in the results of studies selected on an aesthetic basis. 3. The nasolabial angle for this sample was 101.03 degrees with a standard deviation of 8.47 degrees.

The Government Approach to the Eipty Nucleus (지배음운론에서 본 'ㅡ'모음)

  • Heo Yong
    • MALSORI
    • /
    • no.19_20
    • /
    • pp.58-87
    • /
    • 1990
  • According to Government Phonology, at 1 phonological positions save the domain's head must be licensed in order to appear in the syllable structure. A non-nuclear head is licensed by the following nucleus, and the nuclei with phonetic content are licensed through government by the nuclear head of the domain at the level of the nuclear projection. Therefore, in the theory of Government Phonology it is claimed that words always end with a nucleus. With regard to the licensing of empty nuclei, Kaye(1990a) proposes the 'Empty Category Principle' and its sub-theory of 'Projection Government'. Government Phonology claims that a nucleus which dominates a vowel that regularly undergoes elision in certain contexts is underlyingly empty. This underlying empty nucleus is not manifested phonetically when it is properly governed by an unlicensed(i, e, a nucleus filled with a full vowel). It is when proper government fails to apply, that the empty nucleus is phonetically Interpreted. The purpose of this paper is to present a principled account of the process of $[i]{\Leftrightarrow}{\emptyset}$ alternation in Korean. Following Kaye's proposal, we assume that [i] of Korean is underlyingly empty. This position is pronounced as [i] if it is unlicensed, and is not phonetically realized if is licensed. Empty nuclei ape devided into two categories: domain-internal and domain-final. Firstly, we consider the question why Korean has little word ending with [i]. As for this, ECP states that domain-final empty nuclei are not pronounced if the language licenses domain-final empty nuclei. Whether a final empty nucleus may occur in the structure is parametric variation. This property is seen from the fact that words may appear to end in consonants in this language. Since Korean abounds with words ending in a consonant, it licenses domain-final empty nuclei. Therefore, it is quite natural that Korean has little word ending with [i]. Secondly, word-internal empty nuclei of Korean respect proper government and inter-onset government. That is, an empty nucleus in word-internal position will be pronounced with the vowel [i] if either proper government or inter-onset government fail to apply. Inter-onset government refers to the government established between two onsets across an empty nucleus. Thirdly, we consider words ending with [i], which seems to be exceptional to the final licensing. Host of them are. either mono-syllabic verbs(for instance, [s'i-] 'to write') or derived adjectives ending with [p'i] (for instance, [kip'i-] 'be happy'). As for the former, the 'inaccessibility for proper government' is applied because the empty nucleus appears in the first syllable. In latter case, domain-final empty nuclei are pronounced as [i] because of government-licensing. That is, final empty nucleus is pronounced to license the preceding onset dominating negatively charmed segments which empty nucleus of Korean cannot license.

  • PDF

A Comparative Study on the CT Effective Dose by the Position of Patient's Arm (전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구)

  • Seong, Ji-Hye;Park, Soon-Ki;Kim, Jung-Sun;Park, Seung-Yong;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.44-49
    • /
    • 2012
  • Purpose: In the whole body PET/CT scan, it is natural to lift the patient's arm for its quality improvement. However, when the lesion is located in head and neck, the arms should be located lower. This study was designed to compare the CT effective dose for each arm position applying Automatic Exposure Control (AEC). Materials and Methods: 45 patients who had $^{18}F$-FDG whole body PET/CT scan were studied with Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY), Discovery STe 8 (GE healthcare, USA). The CT effective dose of 15 patients for each equipment was measured and comparatively analyzed in both arm-lifted position and lower-arm position. ImPACT v1.0 program was used as the method of measurement for CT effective dose. For the statistics analysis, Paired t-test which paired with SPSS 18.0 statistic program was applied. Results: In the case of arm-lifted, it was measured as $6.33{\pm}0.93mSv$ for Biograph Sensation 16, $8.01{\pm}1.34mSv$ for Biograph Truepoint 40, and $9.69{\pm}2.32mSv$ for Discovery STe 8. When arms are located lower position, it was measure as $6.97{\pm}0.76mSv$, $8.95{\pm}1.85mSv$, $13.07{\pm}2.87mSv$ for each. CT effective dose according to the arm position was 9.2% for Biograph Truepoint 40, 10.5% for Biograph Sensation 16, and 25.9% for Discovery Ste 8. The statistics analysis showed the meaningful difference ($p$<0.05). Conclusion: For the whole body PET/CT case, CT effective dose applying AEC was decreased the radiation exposure of the patients when the arm was lifted for 15.2% of average value. The patient who has no lesion in head and neck would decrease the artifact occurrence in objective part and lower the CT effective dose. Also, for the patient who had lesion in head and neck, the artifact in objective part can be lower by putting the arms down, the fact that CT effective dose increases should be concerned in its whole body PET/CT scan.

  • PDF

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

Study on User-Friendly Rhythm Dance Game Utilizing Beat Element of Music (음악의 비트 요소를 활용한 사용자 친화적 리듬댄스게임 연구)

  • Yi, Tae-Ha;Jeong, Seung-Hwa;Goo, Bon-Cheol
    • Journal of Korea Game Society
    • /
    • v.15 no.2
    • /
    • pp.43-52
    • /
    • 2015
  • This Study suggests the user-friendly game playing method of rhythm dance game focusing on the natural interaction between music and user's movement. When the existing rhythm dance games have given the limitation to users, this study chose the game playing method using beat that is consist of basic element in dance music for minimizing the limitation. Beat feeling method automatically figures out each body position value extracted with Kinect that divided into three parts of shoulder, knee, and head. Accoring to this process, users can play the game to individual dance style, not fixed rules for game.

A CEPHALOMETRIC AND COMPUTERIZED STUDY ON THE CRANIOFACIAL PATTERN IN ADULT WITH NORMAL OCCLUSION (두부방사선계측사진(頭部放射線計測寫眞)과 컴퓨터그래프상(像)을 이용(利用)한 성인정상교합자(成人正常咬合者)의 두개안면형태(頭蓋顔面形態)에 관(關)한 연구(硏究))

  • Kim, Kwang-Won;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.20 no.1
    • /
    • pp.87-100
    • /
    • 1990
  • This study was designed to compare the craniofacial structure of orthodontic patients with that of normal adult. For that purpose, 61 male and 64 female adults with normal occlusion were selected and utilizing the cephalogram that had taken under the natural head position and computerized graphic image, the special position of each anatomical structure against true horizontal and vertical reference plane was investigated. The following results were obtained. 1. The absolute special positions of each anatomic structure were calculated. 2. The inclination of Sella-Nasion plane to true horizontal plane was $8.3^{\circ}{\pm}3.9$ in male and $9.3^{\circ}{\pm}3.2^{\circ}$ in female. 3. The inclination of Frankfort horizontal plane to true horizontal plane was $1.3^{\circ}{\pm}3.0^{\circ}$ in male and $1.7^{\circ}{\pm}3.0^{\circ}$ in female. 4. The dimensions of Nasion-sella and Nasion-Anterior nasal spine to be used as the basic units of mesh diagram were $70.7mm{\pm}3.1mm$, $61.8mm{\pm}2.7mm$ in male and $67.8mm{\pm}3.3mm$, $57.0mm{\pm}2.6mm$ in female respectively. 5. The standard templates of craniofacial structure of male and female adult normal group were constructed. 6. The mesh diagrams of craniofacial structure of male and female adult normal group were constructed.

  • PDF

The Evaluation of Crime Prevention Environment for Cultural Heritage using the 3D Visual Exposure Index (3D 시각노출도를 이용한 문화재 범죄예방환경의 평가)

  • Kim, Choong-Sik
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.35 no.1
    • /
    • pp.68-82
    • /
    • 2017
  • Strengthening surveillance, one of the most important factors in the crime prevention environment of cultural heritages, has difficulty in evaluating and diagnosing the site. For this reasons, surveillance enhancement has been assessed by modelling the shape of cultural heritage, topography, and trees digitally. The purpose of this study is to develop the evaluation method of crime prevention environment for cultural heritage by using the 3D visual exposure index (3DVE) which can quantitatively evaluate the surveillance enhancement in three dimensions. For the study, the evaluation factors were divided into natural, organizational, mechanical, and integrated surveillance. To conduct the analysis, the buildings, terrain, walls, and trees of the study site were modeled in three dimensions and the analysis program was developed by using the Unity 3D. Considering the working area of the person, it is possible to analyze the surveillance point by dividing it into the head and the waist position. In order to verify the feasibility of the 3DVE as the analysis program, we assessed the crime prevention environment by digitally modeling the Donam Seowon(Historic Site No. 383) located in Nonsan. As a result of the study, it was possible to figure out the problems of patrol circulation, the blind spot, and the weak point in natural, mechanical, and organizational surveillance of Donam Seowon. The results of the 3DVE were displayed in 3D drawings, so that the position and object could be identified clearly. Surveillance during the daytime is higher in the order of natural, mechanical, and organizational surveillance, while surveillance during the night is higher in the order of organizational, mechanical, and natural surveillance. The more the position of the work area becomes low, the more it is easy to be shielded, so it is necessary to evaluate the waist position. It is possible to find out and display the blind spot by calculating the surveillance range according to the specification, installation location and height of CCTV. Organizational surveillance, which has been found to be complementary to mechanical surveillance, needs to be analyzed at the vulnerable time when crime might happen. Furthermore, it is note that the analysis of integrated surveillance can be effective in examining security light, CCTV, patrol circulation, and other factors. This study was able to diagnose the crime prevention environment by simulating the actual situation. Based on this study, consecutive researches should be conducted to evaluate and compare alternatives to design the crime prevention environment.