• Title/Summary/Keyword: national reconstruction

Search Result 1,766, Processing Time 0.032 seconds

Performance of ChatGPT 3.5 and 4 on U.S. dental examinations: the INBDE, ADAT, and DAT

  • Mahmood Dashti;Shohreh Ghasemi;Niloofar Ghadimi;Delband Hefzi;Azizeh Karimian;Niusha Zare;Amir Fahimipour;Zohaib Khurshid;Maryam Mohammadalizadeh Chafjiri;Sahar Ghaedsharaf
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.271-275
    • /
    • 2024
  • Purpose: Recent advancements in artificial intelligence (AI), particularly tools such as ChatGPT developed by OpenAI, a U.S.-based AI research organization, have transformed the healthcare and education sectors. This study investigated the effectiveness of ChatGPT in answering dentistry exam questions, demonstrating its potential to enhance professional practice and patient care. Materials and Methods: This study assessed the performance of ChatGPT 3.5 and 4 on U.S. dental exams - specifically, the Integrated National Board Dental Examination (INBDE), Dental Admission Test (DAT), and Advanced Dental Admission Test (ADAT) - excluding image-based questions. Using customized prompts, ChatGPT's answers were evaluated against official answer sheets. Results: ChatGPT 3.5 and 4 were tested with 253 questions from the INBDE, ADAT, and DAT exams. For the INBDE, both versions achieved 80% accuracy in knowledge-based questions and 66-69% in case history questions. In ADAT, they scored 66-83% in knowledge-based and 76% in case history questions. ChatGPT 4 excelled on the DAT, with 94% accuracy in knowledge-based questions, 57% in mathematical analysis items, and 100% in comprehension questions, surpassing ChatGPT 3.5's rates of 83%, 31%, and 82%, respectively. The difference was significant for knowledge-based questions(P=0.009). Both versions showed similar patterns in incorrect responses. Conclusion: Both ChatGPT 3.5 and 4 effectively handled knowledge-based, case history, and comprehension questions, with ChatGPT 4 being more reliable and surpassing the performance of 3.5. ChatGPT 4's perfect score in comprehension questions underscores its trainability in specific subjects. However, both versions exhibited weaker performance in mathematical analysis, suggesting this as an area for improvement.

Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study (Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui;Noh, Gyeong Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2018
  • Purpose Respiratory motion during PET/MRI acquisition may result in image blurring and error in measurement for volume and quantification of lesion. The aim of this study was to evaluate changes of quantitative accuracy, tumor size and image quality by applying MR based respiratory motion correction technique (MBRMCT) using integrated PET/MR scanner. Materials and Methods Data of 30 patients (aged $62.5{\pm}10.2y$) underwent $^{18}F-FDG$ liver PET/MR (Biograph mMR 3.0T, Siemens) study were collected. PET listmode data for 7 minutes was simultaneously acquired with maximum average gate (MAG), minimum time gate (MTG) and non gate (NG) T1 weighted MR images. Gated PET reconstruction was performed using mu-maps generated from MAG and MTG by setting 35% of efficiency window. Maximum SUV ($SUV_{max}$), peak SUV ($SUV_{peak}$), tumor size and full width at half maximum (FWHM) in the z-axis direction of MAG, MTG and NG PET images were evaluated. Results Compared to NG, mean $SUV_{max}$ and $SUV_{peak}$ were increased in MAG 13.15%(p<0.0001), 8.66%(p<0.0001), MTG 13.27%(p<0.0001), 8.80%(p<0.0001) and mean tumor size and FWHM were decreased in MAG 14.47%(p<0.0001), 15.49%(p=0.0004), MTG 14.89%(p<0.0001), 15.79%(p=0.0003) respectively. Mean $SUV_{max}$ and $SUV_{peak}$ of MTG were increased by 0.07%(p=0.8802), 0.13%(p=0.7766). Mean tumor size and FWHM of MTG were decreased by 0.49%(p=0.2786), 0.36%(p=0.2488) compared to MAG. There was no statistically significant difference between MAG and MTG which increase total scan time for about 7 and 2 minutes. Conclusion SUV, accuracy of tumor size and spatial resolution were improved in both of MAG and MTG by applying MBRMCT without installing additional hardware in liver PET/MR study. More accurate information can be provided with the increase of 2 minutes scan time if applying MTG of MBRMCT to various abdominal PET/MR studies affected by respiratory motion.

Paleostress Reconstruction in the Tertiary Basin Areas in Southeastern Korea (한반도 동남부 제3기 분지지역에서의 고응력장 복원)

  • Moon, Tae-Hyun;Son, Moon;Chang, Tae-Woo;Kim, In-Soo
    • Journal of the Korean earth science society
    • /
    • v.21 no.3
    • /
    • pp.230-249
    • /
    • 2000
  • Southeastern Korean Peninsula has undergone the polyphase deformations according to the changes of regional tectonic settings during the Cenozoic. Through analyses of more than 600 fault-slip data gathered in the study area, five tectonic events are revealed as the followings: (I) NW-SE transtension, (II) NW-SE transpression, (III) NE-SW pure or radial extension, (IV) NNE-SSW transpression, (V) NE or ENE-WSW transpression. Event I was induced by the pull-apart type extension of the East Sea during 24-16 Ma, which resulted in the NW-SE extension of the Tertiary Basins in SE Korea. Event II was resulted from the collision of SW Japan and Izu-Bonnin Arc (or Kuroshio Paleoland) on the Philippine Sea Plate at ${\sim}$ 15 Ma, which stopped the extension of the Tertiary Basins and originated the uplift of fault blocks in and around SE Korean Peninsula. It was continued until ${\sim}$ 10 Ma. Event III is interpreted as the post-tectonic event after the block-uplifts due to the event II, which indicates a temporal lull in activity of the Philippine Sea Plate since 10 Ma. Event IV was originated from the resumption in activity of the Philippine Sea Plate which was restarted to move toward north at ${\sim}$ 6 Ma. The event made the EW compressional structures behind SW Japan as well as in the Korea Straits, and thus the block-uplifts in SE Korea was resumed again. Lastly, event V was resulted from the gradual decrease in influence of the Philippine Sea Plate and the cooperative compression due to the subduction of the Pacific Sea Plate and the collision of the Indian Plate since 5-3.5 Ma, which generated the NS compressional structures in the offshore along the eastern coast of the Korean Peninsula and thrust up the fault-blocks toward west. This event is continuing so far, and thus is making the active faultings resulting in the present earthquakes of the Korean Peninsula.

  • PDF

Accuracy Evaluation of CT-Based Attenuation Correction in SPECT with Different Energy of Radioisotopes (SPECT/CT에서 CT를 기반으로 한 Attenuation Correction의 정확도 평가)

  • Kim, Seung Jeong;Kim, Jae Il;Kim, Jung Soo;Kim, Tae Yeop;Kim, Soo Mee;Woo, Jae Ryong;Lee, Jae Sung;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 2013
  • Purpose: In this study, we evaluated the accuracy of CT-based attenuation correction (AC) under the conventional CT protocol (140 kVp, on average 50-60 keV) by comparing the SPECT image qualities of different energy of radioisotopes, $^{201}Tl,\;^{99m}Tc$ and $^{131}I$. Materials and Methods: Using a cylindrical phantom, three different SPECT scans of $^{201}Tl$ (70 keV, 55.5 MBq), $^{99m}Tc$ (140 keV, 281.2 MBq) and $^{131}I$ (364 keV, 96.2 MBq) were performed. The CT image was obtained with 140 kVp and 2.5 mA in GE Hawkeye 4. The OSEM reconstruction algorithm was performed with 2 iterations and 10 subsets. The experiments were performed in the 4 different conditions; non-AC and non-scatter correction (SC), only AC, only SC, AC and SC in terms of uniformity and center to peripheral ratio (CPR). Results: The uniformity was calculated from the uniform whole region in the reconstructed images. For $^{201}Tl$ and $^{99m}Tc$, the uniformities were improved by about 10-20% AC was applied, but these were decreased by about 2% as SC was applied. The uniformity of $^{131}I$ was slightly increased as both AC and SC were applied. The CPR of the reconstructed image was close to one, when AC was applied for $^{201}Tl$ and $^{99m}Tc$ scans and $^{131}I$ was distant from 1 and that is only AC. Conclusion: The image uniformity improved by AC on low energy likely to $^{201}Tl$ and $^{99m}Tc$. However, image uniformity of high energy such as $^{131}I$ was improved, when both AC and SC was applied.

  • PDF

Quantitative Comparisons in $^{18}F$-FDG PET Images: PET/MR VS PET/CT ($^{18}F$-FDG PET 영상의 정량적 비교: PET/MR VS PET/CT)

  • Lee, Moo Seok;Im, Young Hyun;Kim, Jae Hwan;Choe, Gyu O
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.68-80
    • /
    • 2012
  • Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of $^{18}F$-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p<0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.01.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

  • PDF

A Study on the Quality Improvement of Brain Perfusion SPECT Image (뇌혈류 단일광자방출단층촬영 영상 품질 향상에 대한 연구)

  • Kil, Sang-Hyeong;Lim, Yung-Hyun;Park, Gwang-Yeol;Cho, Seong-Mook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.13-19
    • /
    • 2019
  • Purpose Tc-99m HMPAO is widely used radiopharmaceutical for brain perfusion SPECT. Tc-99m HMPAO is chemically unstable and is liable to show deterioration of labeling efficiency due to high incidence of secondary Tc-99m HMPAO complex, free pertechnetate and reduced-hydrolyzed Tc-99m. In this study, we investigated whether sialogogues administration could reduce the impurities of Tc-99m HMPAO. Materials and Methods In thirty subjects(20 male and 10 female, age range 19~89 years, mean age $60.7{\pm}14.5years$), brain perfusion SPECT were performed at basal and citric acid stimulation states consecutively after injection of 555 MBq of Tc-99m HMPAO. In the salivary glands, the uptake coefficient was calculated using Siemens processing program. Statistical comparison between before and after the citric acid stimulation performed paired t-test. P value less than 0.05 was regarded as statistically significant. Results Salivary glands uptake was $12900{\pm}3101$ counts in basal and $10677{\pm}2742$ counts in citric acid stimulation states. Unnecessary impurities in the body is much decreased after citric acid administration(t=10.78, P<0.05). The image quality was much improved after administration of citric acid and the regional cerebral perfusion was clearly from demarcated the background. Conclusion The impurity is distributed throughout the body particularly in the salivary glands and nasal mucosa when Tc-99m HMPAO brain perfusion SPECT is performed. If this impurities is not removed, the quality of the image may deteriorate, resulting in errors in visual evaluation. The use of sialogogues could be helpful for decreasing unnecessary impurities in the body.

The Effect of Participation Degree in Sports for all of People with Physical Disabilities on Positive Psychological Capital(PPC) (지체장애인의 생활체육 참여정도가 긍정심리자본(PPC)에 미치는 영향)

  • Kim, Dae-Kyung;Park, Jin-Woo;Kim, Hye-Min;Lee, Hyun-Su
    • 한국체육학회지인문사회과학편
    • /
    • v.54 no.5
    • /
    • pp.867-876
    • /
    • 2015
  • This study was intended to closely examine an effect that the level of physically challenged person's participation in community sports had on positive psychological capital. In order to accomplish the purpose of study, data on 212 physically challenged persons who lived in B city and participated in community sports were analyzed. Korean version of positive psychological capital created by Taehong Lim (2014) through the reconstruction of scales developed by Luthans, Youssef and Avolio(2007) and Sangwan Jeon and Jonghun Yang's (2009) level of participation in community sports was reconstructed through modification·improvement as measurement instrument. An exploratory factor analysis, reliability test, paired difference test, and multiple regression analysis was carried out by using SPSS 18.0 program for data processing. First, It was shown that there was a significant difference in positive psychological capital according to gender, age, and disability grade among physically challenged persons' socio-demographic characteristics. Second, it was shown that, among sub-variables (period, frequency and intensity) of level of physically challenged persons' participation in community sports, the frequency of participation and the intensity of participation had a significant effect on self efficacy. On the other hand, it was shown that the period of participation didn't have a significant effect. Third, it was shown that the frequency of participation had a significant effect on optimism. On the other hand, it was shown that the period of participation and the intensity of participation didn't have a significant effect. Fourth, it was shown that the frequency of participation and the intensity of participation had a significant effect on hope. On the other hand, it was shown that no significant effect was produced on the period of participation. Fifth, it was shown that the frequency of participation had a significant effect on resilience. On the other hand, it was shown that no significant effect was produced on the period of participation and the intensity of participation. Sixth, it was shown that the frequency of participation and the intensity of participation had a significant effect on positive psychological capital. And it was shown that no significant effect was produced on the period of participation.

Performance Evaluation of Radiochromic Films and Dosimetry CheckTM for Patient-specific QA in Helical Tomotherapy (나선형 토모테라피 방사선치료의 환자별 품질관리를 위한 라디오크로믹 필름 및 Dosimetry CheckTM의 성능평가)

  • Park, Su Yeon;Chae, Moon Ki;Lim, Jun Teak;Kwon, Dong Yeol;Kim, Hak Joon;Chung, Eun Ah;Kim, Jong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.93-109
    • /
    • 2020
  • Purpose: The radiochromic film (Gafchromic EBT3, Ashland Advanced Materials, USA) and 3-dimensional analysis system dosimetry checkTM (DC, MathResolutions, USA) were evaluated for patient-specific quality assurance (QA) of helical tomotherapy. Materials and Methods: Depending on the tumors' positions, three types of targets, which are the abdominal tumor (130.6㎤), retroperitoneal tumor (849.0㎤), and the whole abdominal metastasis tumor (3131.0㎤) applied to the humanoid phantom (Anderson Rando Phantom, USA). We established a total of 12 comparative treatment plans by the four geometric conditions of the beam irradiation, which are the different field widths (FW) of 2.5-cm, 5.0-cm, and pitches of 0.287, 0.43. Ionization measurements (1D) with EBT3 by inserting the cheese phantom (2D) were compared to DC measurements of the 3D dose reconstruction on CT images from beam fluence log information. For the clinical feasibility evaluation of the DC, dose reconstruction has been performed using the same cheese phantom with the EBT3 method. Recalculated dose distributions revealed the dose error information during the actual irradiation on the same CT images quantitatively compared to the treatment plan. The Thread effect, which might appear in the Helical Tomotherapy, was analyzed by ripple amplitude (%). We also performed gamma index analysis (DD: 3mm/ DTA: 3%, pass threshold limit: 95%) for pattern check of the dose distribution. Results: Ripple amplitude measurement resulted in the highest average of 23.1% in the peritoneum tumor. In the radiochromic film analysis, the absolute dose was on average 0.9±0.4%, and gamma index analysis was on average 96.4±2.2% (Passing rate: >95%), which could be limited to the large target sizes such as the whole abdominal metastasis tumor. In the DC analysis with the humanoid phantom for FW of 5.0-cm, the three regions' average was 91.8±6.4% in the 2D and 3D plan. The three planes (axial, coronal, and sagittal) and dose profile could be analyzed with the entire peritoneum tumor and the whole abdominal metastasis target, with planned dose distributions. The dose errors based on the dose-volume histogram in the DC evaluations increased depending on FW and pitch. Conclusion: The DC method could implement a dose error analysis on the 3D patient image data by the measured beam fluence log information only without any dosimetry tools for patient-specific quality assurance. Also, there may be no limit to apply for the tumor location and size; therefore, the DC could be useful in patient-specific QAl during the treatment of Helical Tomotherapy of large and irregular tumors.

A Study on the Locational and Spatial Characteristics of Lotus Ponds of Fortress Wall of Seoul(漢陽都城) during the Joseon Dynasty (조선시대 한양도성 연지(蓮池)의 입지 및 공간적 특성 고찰)

  • Gil, Ji-Hye;Son, Yong-Hoon;Hwang, Kee-Won
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.33 no.4
    • /
    • pp.38-51
    • /
    • 2015
  • In the maps of the period, there were three large ponds called Dongji(東池), Seoji(西池) and Namji(南池) in Hanyang, the capital of Joseon Dynasty. They were different than the ponds found in the palace, civic buildings, and private dwellings. Dongji, Seoji and Namji were ponds relating to Fortress wall of Seoul, and all had lotuses cultivated in them. The purpose of this paper is to clarify the locational and spatial characteristics of these ponds and to detail the construction and reconstruction process and management conditions through maps, drawings, illustrations, historical records and literary works from the urban environmental perspective. The results are as follows. First, Seoji and Namji were intended for Bibo(裨補) which redeemed the geographical weaknesses of Hanyang, securement of bright court water(明堂水), supplement for fire energy(火氣), fire preventive water and waterscape facilities, while Dongji was emphasized on protecting water mouth(水口) besides Bibo and securement of bright court water. Second, Seoji was connected to mountain streams and Dongji and Namji were to ditches. The ponds connected to ditches had been difficult to fill and maintain. Third, Seoji and Namji were in urban areas, whereas Dongji was in farmlands, and these locational differences had an influence on the use of ponds. Fourth, the shapes of ponds, in contrast to the ponds in palace and civic buildings, which were perfectly square, were either freeform or square with rounded edges. Fifth, lotus ponds could be maintained by continuous management polices, earth filling and reconstructing process were repeated during the Joseon Dynasty. The lotus ponds of Fortress Wall of Seoul which had managed over 500 years, were built in, in accordance with the tenets of Bibo pungsu geomancy; however as time passed, they were maintained not only as public open spaces, but also a cultural attraction for residents and visitors.

Clinical Usefulness of PET-MRI in Lymph Node Metastasis Evaluation of Head and Neck Cancer (두경부암 림프절 전이 평가에서 PET-MRI의 임상적 유용성)

  • Kim, Jung-Soo;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.26-32
    • /
    • 2014
  • Purpose: As PET-MRI which has excellent soft tissue contrast is developed as integration system, many researches about clinical application are being conducted by comparing with existing display equipments. Because PET-MRI is actively used for head and neck cancer diagnosis in our hospital, lymph node metastasis before the patient's surgery was diagnosed and clinical usefulness of head and neck cancer PET-MRI scan was evaluated using pathological opinions and idiopathy surrounding tissue metastasis evaluation method. Materials and Methods: Targeting 100 head and neck cancer patients in SNUH from January to August in 2013. $^{18}F-FDG$ (5.18 MBq/kg) was intravenous injected and after 60 min of rest, torso (body TIM coil, Vibe-Dixon) and dedication (head-neck TIM coil, UTE, Dotarem injection) scans were conducted using $Bio-graph^{TM}$ mMR 3T (SIEMENS, Munich). Data were reorganized using iterative reconstruction and lymph node metastasis was read with Syngo.Via workstation. Subsequently, pathological observations and diagnosis before-and-after surgery were examined with integrated medical information system (EMR, best-care) in SNUH. Patient's diagnostic information was entered in each category of $2{\times}2$ decision matrix and was classified into true positive (TP), true negative (TN), false positive (FP) and false negative (FN). Based on these classified test results, sensitivity, specificity, accuracy, false negative and false positive rate were calculated. Results: In PET-MRI scan results of head and neck cancer patients, positive and negative cases of lymph node metastasis were 49 and 51 cases respectively and positive and negative lymph node metastasis through before-and-after surgery pathological results were 46 and 54 cases respectively. In both tests, TP which received positive lymph node metastasis were analyzed as 34 cases, FP which received positive lymph node metastasis in PET-MRI scan but received negative lymph node metastasis in pathological test were 4 cases, FN which received negative lymph node metastasis but received positive lymph node metastasis in pathological test was 1 case, and TN which received negative lymph node metastasis in both two tests were 50 cases. Based on these data, sensitivity in PET-MRI scan of head and neck cancer patient was identified to be 97.8%, specificity was 92.5%, accuracy was 95%, FN rate was 2.1% and FP rate was 7.00% respectively. Conclusion: PET-MRI which can apply the acquired functional information using high tissue contrast and various sequences was considered to be useful in determining the weapons before-and-after surgery in head and neck cancer diagnosis or in the evaluation of recurrence and remote detection of metastasis and uncertain idiopathy cervical lymph node metastasis. Additionally, clinical usefulness of PET-MRI through pathological test and integrated diagnosis and follow-up scan was considered to be sufficient as a standard diagnosis scan of head and neck cancer, and additional researches about the development of optimum MR sequence and clinical application are required.

  • PDF