• 제목/요약/키워드: nail withdrawal load

검색결과 6건 처리시간 0.016초

Influence of Earlywood, Latewood, and Nail Driving Position on Nail Withdrawal Load Behavior

  • Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권2호
    • /
    • pp.1-5
    • /
    • 1998
  • Nail withdrawal tests were conducted on clear wood of radiata pine. Nails were driven into the earlywood and latewood zones of each specimen, and nail withdrawal tests were then performed. Nail withdrawal loads were strongly dependent on earlywood and latewood and on nail position. The average load values for nail withdrawal in both the tangential and longitudinal directions were higher for latewood than for earlywood. Linear and nonlinear regression analyses of nail withdrawal load with specific gravity showed no discernible differences. Good correlations were obtained between nail withdrawal load and specific gravity.

  • PDF

Nail Withdrawal Behavior for Domestic Small Diameter Logs

  • Cha, Jae-Kyung
    • Journal of the Korean Wood Science and Technology
    • /
    • 제30권3호
    • /
    • pp.104-108
    • /
    • 2002
  • Nail withdrawal tests were conducted on clear wood of domestic small diameter logs. Nails were driven into the cross and longitudinal sections of each specimen, then nail withdrawal tests were performed. Nail withdrawal loads are strongly dependent on the direction of nail positions. The average load values for the nail withdrawal both in cross section and longitudinal section are higher in high specific gravity (SG) wood of sawtooth oak (Quercus acutissima Carr.) than those in low SG wood of Korean red pine (Pinus densiflora Sieb. et Zucc.) and pitch pine (Pinus rigida Mill.). The average ratio of the nail withdrawal loads for side-grain and end-grain are higher in the low SG wood than that in the high SG of wood. Both linear and non-linear regression analyses were conducted on nail withdrawal load with SG, good correlations were obtained between nail withdrawal load and SG.

Refined damage prediction of low-rise building envelope under high wind load

  • Pan, F.;Cai, C.S.;Zhang, W.;Kong, B.
    • Wind and Structures
    • /
    • 제18권6호
    • /
    • pp.669-691
    • /
    • 2014
  • Since low-rise residential buildings are the most common and vulnerable structures in coastal areas, a reliable prediction of their performance under hurricanes is necessary. The present study focuses on developing a refined finite element model that is able to more rigorously represent the load distributions or redistributions when the building behaves as a unit or any portion is overloaded. A typical 5:12 sloped low-rise residential building is chosen as the prototype and analyzed under wind pressures measured in the wind tunnel. The structural connections, including the frame-to-frame connections and sheathing-to-frame connections, are modeled extensively to represent the critical structural details that secure the load paths for the entire building system as well as the boundary conditions provided to the building envelope. The nail withdrawal, the excessive displacement of sheathing, the nail head pull-through, the sheathing in-plane shear, and the nail load-slip are found to be responsible for the building envelope damage. The uses of the nail type with a high withdrawal capacity, a thicker sheathing panel, and an optimized nail edge distance are observed to efficiently enhance the building envelope performance based on the present numerical damage predictions.

경골목구조에서 구조재와 오에스비로 구성된 못 접합부의 인발 및 전단성능 (Withdrawal and Lateral Resistance of Nail Joints Composed of Dimension Lumber and OSB in Light-Frame Wood Construction)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권3호
    • /
    • pp.211-220
    • /
    • 2013
  • 경골목조건축에서 못 접합부는 수평하중을 지지하고 전달하도록 설계되지만, 바람으로 인한 상향력처럼 인발하중에 직면하기도 한다. 본 연구에서는 경골목조건축에서 일반적으로 사용되는 구조재와 덮개로 구성된 못 접합부에 대하여 인발성능과 2면 전단시험을 통해 인발 및 측방하중에 대한 내력성능을 시험하고 설계기준에 부합되는 가를 평가하였다. 인발하중에 대한 내력성능은 부재의 비중에 의해 크게 좌우되었으며 I형장선의 경우 낮은 밀도에도 불구하고 높은 인발성능을 나타내었다. 최대 인발하중은 기준허용 최대 인발하중보다 매우 높게 나타났다. 전단성능도 비중이 큰 낙엽송과 오에스비로 구성된 접합부가 비중이 작은 SPF와 오에스비로 구성된 접합부보다 높은 성능을 나타내었으며 모두 기준설계치보다 높은 성능을 나타내었다. 접합부의 변형은 주로 못의 휨 변형에 의한 것으로 나타났으며 SPF와 오에스비로 구성된 접합부에서의 못의 휨 변형이 현저하게 나타났다.

침엽수 합판의 구조용 및 콘크리트 거푸집용으로서의 성능 평가 (Performance Evaluation of Softwood Plywood as Structural and Concrete-Form Panels)

  • 이전제;김광철;이국식
    • Journal of the Korean Wood Science and Technology
    • /
    • 제28권3호
    • /
    • pp.14-24
    • /
    • 2000
  • 본 연구에서는 향후 공급량이 증가될 것으로 예상되는 라디아타소나무와 국산 낙엽송의 두 수종을 이용하여 합판을 제조하고 구조용 합판 및 콘크리트 거푸집용 합판으로서의 사용 가능성을 검토하고자 하였다. 먼저, 기초적인 재질을 평가하기 위하여 합판의 재질시험 및 못성능 등의 시험을 실시하였고, 콘크리트조 주택 혹은 목조주택 등의 구조용 재료로의 사용을 검토하기 위해 집중하중과 균일분포하중에 의한 구조성능 시험 및 콘크리트 거푸집용으로서의 성능시험을 실시하였다. 합판의 기초 재질에 해당되는 비중, 너비 굽음, 길이 굽음 비틀림에 대한 실험 결과, 구조용 재료로서의 기준을 만족하였다. 못 측면 저항력, 못 인발 저항력 그리고 못머리 관통력에 대한 실험 결과, 구조용 재료로서의 벽체나 지붕재에 대한 표준성능을 만족하였다. 이들 두 수종으로 제조한 합판의 경우, 집중하중과 균일 분포하중에 의한 구조성능 평가, 콘크리트 거푸집용으로서의 성능 평가 결과를 볼 때 구조용 덮개재, 바탕바닥 마감재, 콘크리트 거푸집용 재료로의 사용이 가능하다고 판단되었다.

  • PDF

인사이징 처리 낙엽송 CCA-방부원주목의 강도 성능 평가 (Strength Property of the Incised Larix (Larix kaempferi Carr.) Round Posts treated with CCA)

  • 박준철;김상우;류재윤;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제36권3호
    • /
    • pp.85-92
    • /
    • 2008
  • 본 연구에서는 인사이징 처리 낙엽송 방부 원주목의 강도 성능을 평가하기 위하여 원목, 원주목과 강도 성능을 비교 분석하였다. 원목과 원주목의 휨강도(MOR)는 큰 차이가 없었다. 인사이징 처리 방부 원주목은 휨탄성 계수(MOE)가 9% 감소하였고 휨강도는 원목에 대한 강도비 0.71로 약 29% 강도의 저하를 보였다. 일반적인 2인치 제재목이 아닌 원주 형태의 원주목을 이용한 휨허용응력 산정시 인사이징 방부처리 저감계수를 휨탄성계수는 0.91, 휨강도는 0.71로 적용해야 할 것으로 사료된다. 못뽑기 저항은 원목, 원주목, 방부 원주목 모두 큰 차이를 보이지 않았다. 볼트 접합부의 전단력은 인사이징 처리 방부 원주목과 원주목의 차이는 거의 나타나지 않았다. 볼트 접합부의 허용 전단 내력 산정에는 인사이징 저감 계수의 적용은 검토하지 않아도 됨을 확인할 수 있었다.