• Title/Summary/Keyword: nafion (perfluorinated sulfonated polymer)-ethylenediamine modified glassy carbon electrode

Search Result 4, Processing Time 0.021 seconds

Determination of Cadmium(II) Ion Using the Nafion-Ethylenediamine-Modified Glassy Carbon Electrode (Nafion-Ethylenediamine이 수식된 유리탄소전극에 의한 Cd(II) 이온의 정량)

  • Kim, Jin Ah;Ko, Young Chun;Park, Chan Ju;Park, Byung Ho;Chung, Keun Ho
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.123-130
    • /
    • 2001
  • Determination of cadmium(II) ion with a perfluorinated sulfonated polymer-ethylenediamine(nafion-en) modified glassy carbon electrode was studied. It was based on the chemical reactivity of an immobilized layer(nafion-en) to yield complex $[Cd(en)_2]^{2+}$. The reduction peak potential by differential pulse voltammetry(DPV) was observed at $-0.780({\pm}0.005)V$ vs. As/AgCl. The linear calibration curve was obtained in cadmium(II) ion concentration range $5.0{\times}10^{-7}-2.0{\times}10^{-5}M$, and the detection limit(3s) was $2.20{\times}10^{-7}M$. The detection limit of nafion-en modified glassy carbon electrode has been shown about 14 higher sensitivity than a bare glassy carbon electrode.

  • PDF

Determination of Copper(II) ion with a nafion-ethylenediamine modified glassy carbon electrode (내피온-에틸렌디아민이 수식된 유리탄소전극으로 구리(II) 이온의 정량)

  • Ko, Young Chun;Kim, Hee Cheol
    • Analytical Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.213-218
    • /
    • 2007
  • Copper(II) ion was measured with the use of a perfluorinated sulfonated polymer-ethylenediamine (nafion-en) modified glassy carbon electrode. The electrode mechanism was based on the chemical reactivity of an immobilized layer (nafion-en) to yield complex $[Cu(en)_2]^{+2}$. The reduction potential peak by differential pulse voltammetry(DPV) was observed at -0.4402V(${\pm}0.0050V$) (vs. Ag/AgCl). The linear calibration curve was obtained from $1.0{\times}10^{-6}$ to $1.0{\times}10^{-4}M$ copper(II) ion concentration, and the detection limit(3s) was $1.96{\times}10^{-6}M$.

Determination of Cobalt(III) Ion Using a Nafion-Ethylenediamine Modified Glassy Carbon Electrode

  • Kim, Seok Jin;Ko, Young Chun
    • Journal of Integrative Natural Science
    • /
    • v.7 no.3
    • /
    • pp.188-192
    • /
    • 2014
  • Determination of cobalt(III) ion with a perfluorinated sulfonated polymer-ethylenediamine (nafion-en) modified glassy carbon electrode is studied. It is based on the chemical reactivity of an immobilized layer, nafion-en, to yield complex $[Co(en)_3]^{3+}$. The reduction peak potential by differential pulse voltammetry (DPV) is observed at $-0.437{\pm}0.047$ V (vs. Ag/AgCl). The linear calibration curve is obtained in cobalt(III) ion concentration range $1.0{\times}10^{-8}{\sim}1.0{\times}10^{-3}M$ ($5.893{\times}10^{-12}{\sim}5.893{\times}10^{-5}g/mL$).

Differential Pulse Voltammetric Determination of Iron(II) ion with a Nafion-Ethylenediamine Modified Glassy Carbon Electrode (Nafion-ethylenediamine이 수식된 유리탄소전극에 의한 시차펄스전압전류법으로 철(II) 이온의 정량)

  • Kyong Wone Kim;Hee Cheol Kim;Sung-Hyun Kim;Byung Ho Park;Yeon Hee Kim;Kyong Nam Kim;Yong Chun Ko
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.2
    • /
    • pp.115-120
    • /
    • 2003
  • Determination of iron(II) ion with a perfluorinated sulfonated polymer(nafion)-ethylenediamine(en) modified glassy carbon electrode was studied. It was based on the chemical reactivity of an immobilized layer(nafion-en) to yield complex $[Fe(en)_3]^{+2}$. The oxidation peak potential by differential pulse voltammetry(DPV) was observed at 0.340${\pm}$0.015 V(vs. Ag/AgCl). The linear calibration curve was obtained in iron(II) ion concentration range $5{\times}10^{-6}{\sim}0.2{\times}10^{-3} M(0.28{\sim}11.17\; mg/L)$, and the detection limit(3s) was $1.89{\times}10^{-5}$M(1.056 mg/L).