• 제목/요약/키워드: nGrinder

검색결과 9건 처리시간 0.027초

페룰가공용 무심연삭기 이송계 개발 (A Study on the Feeding System of Centerless Grinder for Machining the Ferrule)

  • 박천홍;황주호;조순주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.65-69
    • /
    • 2002
  • In order to practicalize high precision centerless grinder for machining the ferrule, its feeding system is designed and tested. For satisfying the desired diametric tolerance and cylindricity of the ferrule, the feeding system is designed to have relatively high axial stiffness of 600 N/$\mu\textrm{m}$, high angular motion accuracy of 0.5 arcsec/mm in yaw direction and minimum resolution of 0.05 $\mu\textrm{m}$. A prototype of feeding system is built up with hydrostatic guideway and ballscrew. A linear scale with 0.05 $\mu\textrm{m}$ of resolution is used for position feedback. Experimental results show that the feeding system has the infinity of axial stiffness within the range of 1000 N and 0.3 arcsec/mm of yawing error. Also the feeding system shows obvious step response against 0.05 $\mu\textrm{m}$/step command without the lost motion or backlash. Although the vertical stiffness is reduced to 440 N/$\mu\textrm{m}$ by the elastic deformation of rail, it is good enough to use for machining the ferrule. From above, it is confirmed that the feeding system is applicable to centerless grinder for machining the ferrule.

  • PDF

공간정보 오픈플랫폼 서비스의 성능 분석 및 자원 재조정 방안에 관한 연구 (A Study on Performance Analysis and Resource Re-distribution Method of the Spatial Information Open Platform Service)

  • 장한솔;고준희;김민수;장인성
    • Spatial Information Research
    • /
    • 제23권4호
    • /
    • pp.1-11
    • /
    • 2015
  • 2012년 1월부터 공간정보 오픈플랫폼의 서비스가 시작된 이래로, 서비스가 늘어남에 따라 서비스 이용자 수와 시스템의 규모가 크게 증가하게 되었다. 그러나 이러한 오픈플랫폼 시스템이 가지고 있는 하드웨어 자원들이 어느 수준의 서비스를 처리할 수 있는지에 대한 자세한 분석 결과는 전혀 알 수 없었다. 이러한 이유로 특정 이슈와 더불어 서비스 이용자가 급증할 때마다 서비스를 처리하기 위하여 단순히 하드웨어 증설을 통해 일시적으로 서비스 지연 문제를 해결하여 왔다. 이에 본 연구에서는 현재 오픈플랫폼이 보유하고 있는 시스템 성능을 정확히 파악하여 향후 동일한 문제가 발생하지 않도록 근본적인 해결책을 제시하고자 한다. 구체적으로 본 연구에서는 NMON을 이용한 하드웨어 성능 분석과 nGrinder를 이용한 웹서비스 부하 테스트를 통해 오픈플랫폼이 현재 가지고 있는 정확한 시스템 성능을 파악하고, 이후 보다 나은 서비스를 제공할 수 있는 시스템으로 개선하기 위한 자원 재조정 방안을 제시하고자 한다.

그라인딩 작업시 손목자세별 국소진동 전달특성 분석 (An Analysis of Transmitted-Vibration Characteristics by Different Wrist Posture during Grinding Tasks)

  • 황성환;이동춘
    • 대한인간공학회지
    • /
    • 제26권1호
    • /
    • pp.29-37
    • /
    • 2007
  • This study was performed to evaluate the characteristics of transmitted vibration to hand-arm system under different work posture while operating a light-weighted powered hand grinder. For the experiment, 8 different types of wrist posture (natural, unlar-flexion, radual-flexion, flexion, extension, complex posture, and etc.) and 3 types of feed force (20[N], 50[N], 70[N]) were considered. 10 male subjects were employed to polish metal plate with a hand grinder. All of them were normal and healthy with no history and symptom of the work related musculoskeletal disorders in the dominant hand. Vibration acceleration data were recorded with sampling rate, 2048[Hz]. In addition, unweighted overall R.M.S. acceleration at the tool and wrist, and transmissibility between them were used to evaluate factors from the recorded tri-axial vibration acceleration. The results indicate that transmissibility of natural wrist posture was significantly higher than others. In addition, as the feed force becomes larger, the vibration was transmitted in large quantities to hand-arm system through radius.

연삭시스템의 최적연삭가공조건 (The Optimum Grinding Condition Selection of Grinding System)

  • 이석우;최영재;허남환;최헌종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.563-564
    • /
    • 2006
  • In silicon wafer manufacturing process, the grinding process has been adopted to improve the flatness of water. The grinding of wafer is usually used by the infeed grinding machine. Grinding conditions are spindle speed, feed speed, rotation speed, grinding stone etc. But grinding condition selection and analysis is so difficult in grinding machine. In the intelligent grinding system based on knowledge many researchers have studied expert system, neural network, fuzzy etc. In this paper we deal grinding condition selection method, Taguchi method and Genetic Analysis.

  • PDF

A1 합금의 미세 절삭가공 및 경면생성에 관한 연구

  • 제태진;김원일;이재경
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1991년도 춘계학술대회 논문집
    • /
    • pp.103-110
    • /
    • 1991
  • 본 연구에서는 최근들어 첨단 가공기술로서 중요시되고있는 초정밀 경면가공기술의 기본원리를 이해하고 관련지식을 습득하여 향후 보다 나은 상태의 경면가공을 위한 기초를 확립하는데에그 목적을 두었다. 실험을 위한 공작기계는 초정밀 만능 연삭반( high precision universal grinder)에 플라이컷(fly-cut)방식에 의한 절삭가공이 가능 하도록 여러가지장치들을 부착하였으며, 절삭공구는 천연 다이아몬드를 사용하고, 피삭재는 A1-Cu-Ni-Mg 합금을 사용하였다. 본 실험에서는 주어진 조건내에서 어느정도의 표면 조도를 달성할수 있는지를 알아보고 그 과정을 통하여 공작기계, 공구, 피삭재등의 영향과 절삭력, 칩, 표면상태등을 고찰하여 여러가지 현상을 규명하여 향후의 발전을 위한 대책에 활용하고자 한다.

필렛용접이음부의 후처리에 따른 피로강도 향상 메커니즘의 연구 (The Study about the Fatigue Strength Improvement Mechanism by the Processing of Fillet Welded Joint)

  • 임청권;박문호;장준호
    • 한국강구조학회 논문집
    • /
    • 제11권3호통권40호
    • /
    • pp.319-327
    • /
    • 1999
  • 본 연구는 필렛용접 이음으로 된 종리브 십자 시험체를 대상으로 용접토우의 후처리에 의한 피로강도 향상의 메커니즘을 밝히고, 적절한 후처리법을 제안하고자 한다. 인장피로시험 결과, 용접 그대로의 시험체 보다는 후처리된 시험체들에서 피로강도 향상이 보였다. 특히, 피로균열 발생수명 $N_c$는 해머피닝(Hammer-Peening)후 그라인더 처리를 한 시험체에서, 그리고 피로균열 진전수명 $N_p$는 해머피닝 시험체 들에서 각각 증가현상을 보였다. 여기서, $N_c$는 용접토우의 기하학적 형상, 즉 응력집중의 완화때문에, 또한 $N_p$는 해머피닝에 의해 표면에 도입된 큰 압축잔류응력이 피로균열의 진전을 억제하고 있기 때문이라고 생각된다.

  • PDF

Clinical Analysis of the Patients with Isolated Low-Velocity Penetrating Neck Injury

  • Seok, Junepill;Cho, Hyun Min
    • Journal of Trauma and Injury
    • /
    • 제31권1호
    • /
    • pp.1-5
    • /
    • 2018
  • Purpose: Although there has been substantial progress for the treatment of thoracic trauma, the mortality of the penetrating neck injury is still high, has been reported about 10-15%. However, there has not been a report which is reflecting Korean medical present. We retrospectively analyzed the penetrating neck injury patients based on the Korean Trauma Data Base. Methods: Between December 2013 and June 2017 at the trauma center of the Pusan National University Hospital, Busan, Korea, total of 36 patients with isolated low-velocity penetrating neck injuries were included. We analyzed the patients' age, gender, injury mechanism and causes by medical chart review. Results: Among total of 36 patients, 26 (72.2%) were male and 10 (27.8%) were female. Homicidal neck injuries were most common, followed by accidental and suicidal injuries (47% vs. 33% vs. 19%, respectively). All penetrating injuries in our study were low-velocity trauma such as following: knife (n=16, 44.4%); glass or glass bottle (n=11, 30.6%); scissors (n=4, 11.1%); grinder (n=2, 5.6%); and three (8.3%) of miscellaneous injuries. Twenty-seven (75.0%) patients underwent emergency surgery, and only one (2.8%) patient underwent elective surgery. Eleven (30.6) patients were diagnosed with superficial injuries, including six patients who had conservative treatment. Twelve (33.3%) patients had arterial injuries and 10 (27.8%) patients had venous injuries. The patients who had deep injuries showed significant difference against the patient with superficial injury (98.0 vs. 129.1, p=0.008). Conclusions: Low velocity penetrating injury confined to the neck is able to be successfully treated with prompt surgical management. Regardless of the conditions which are evaluated at emergency department, all penetrating neck injury patients should be regarded as urgent surgical candidates.

자동차 조립공정에서 공기압력식 진동공구의 국소진동평가 (Assessment of Vibration Produced by Pneumatic Hand Tools Used in Automobile Assembly)

  • 김선술;백남원
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.1-16
    • /
    • 1996
  • This study was conducted at an automobile assembly line located in Kyonggi-do, Korea from January 16 to February 28, 1995. The purposes of this study were to assess worker exposures to hand-arm vibration and the performance of gloves for reduction of vibration. The exposure to vibration was measured using to the ISO 5349(1986) method. Vibration acceleration and frequency spectra for each tool were determined on-line replicating actual working conditions and analyzed together with exposure time for evaluating individual worker exposure. Eight pneumatic hand tools, 60 workers exposured to hand-arm vibration, and three pairs of gloves were involved in this study. Results are summarized as follows. 1. Dominant frequencies of vibration for all tools(n=8) measured in this study ranged from 250 Hz to 800 Hz. 2. There was no significant correleration between dominant frequencies and free running speed (p>0.05). 3. Total predicted exposure times of using impact, hammer type did not exceed 40 minutes, but metal finish task, using grinder and sander exceeded 40 minutes. Total exposure time affected significantly the frequency-weighted, 4 hr equivalent acceleration. 4. Predicted prevalence and observed exposure period data were compared in workers(n=60), according to ISO 5349. In this results, 23(50.0 %) and 24(48.07 %) persons exceeded the mean latency periods for vibration-induced white finger(VWF) at 10 % (n=46) and 50 % (n=52) standards, respectively. On the basis of ISO equation, mean latent periods for VWF were 3.23, 4.72 years at 10 %, 50 % standards, respectively. 5. Reduction of vibration by gloves was evaluated. Since impact pneumatic tools produced low frequency vibrations, conventional gloves did not provide any protection. Gloves A and C amplify somewhat the signal at frequency below 400 Hz; the attenuation increases progressively by frequency to reach 18 dB ($7.94{\times}10^{-6}m/s^2$) at 1,000 Hz, slightly worsening Glove B did not provide any protection and made the situation slightly worse. However, since they make the hands warm, the occurrence of vibration-induced white fingers may be reduced.

  • PDF

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.