• Title/Summary/Keyword: multiple-slit

Search Result 24, Processing Time 0.017 seconds

SPATIALLY RESOLVED KINEMATICS OF GAS AND STARS IN HIDDEN TYPE 1 AGNS

  • Son, Donghoon;Woo, Jong-Hak;Eun, Da-In;Cho, Hojin;Karouzos, Marios;Park, Songyeon
    • Journal of The Korean Astronomical Society
    • /
    • v.53 no.5
    • /
    • pp.103-115
    • /
    • 2020
  • We analyze the spatially resolved kinematics of gas and stars for a sample of ten hidden type 1 AGNs in order to investigate the nature of their central sources and the scaling relation with host galaxy stellar velocity dispersion. We select our sample from a large number of hidden type 1 AGNs, which are identified based on the presence of a broad (full width at half maximum ≳1000 km s-1) component in the Hα line profile and which are frequently mis-classified as type 2 AGNs because AGN continuum and broad emission lines are weak or obscured in the optical spectral range. We used the Blue Channel Spectrograph at the 6.5-m Multiple Mirror Telescope to obtain long-slit data with a spatial scale of 0.3 arcsec pixel-1. We detected broad Hβ lines for only two targets; however, the presence of strong broad Hα lines indicates that the AGNs we selected are all low-luminosity type 1 AGNs. We measured the velocity, velocity dispersion, and flux of stellar continuum and gas emission lines (i.e., Hβ and [O III]) as a function of distance from the center. The spatially resolved gas kinematics traced by Hβ or [O III] are generally similar to the stellar kinematics except for the inner center, where signatures of gas outflows are detected. We compare the luminosity-weighted effective stellar velocity dispersions with the black hole masses and find that our hidden type 1 AGNs, which have relatively low back hole masses, follow the same scaling relation as reverberation-mapped type 1 AGN and more massive inactive galaxies.

Improvement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Study

  • Kim, Sung Hun;Park, Jong Hoon;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Jeong, Jong Hwi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Background: To monitor proton beam in proton therapy, prompt gamma imaging systems are being developed by several research groups, and these systems are expected to improve the quality of the treatment and the patient safety. To apply the prompt gamma imaging systems into spot scanning proton therapy, the systems should be able to monitor the proton beam range of a spot with a small number of protons ( <$10^8$ protons), which is quite often not the case due to insufficient prompt gamma statistics. Materials and Methods: In the present study, we propose to improve prompt gamma statistics by merging the prompt gamma distributions of several individual spots into a new distribution. This proposal was tested by Geant4 Monte Carlo simulations for a multi-slit prompt gamma camera which has been developed to measure the proton beam range in the patient. Results and Discussion: The results show that the proposed method clearly enhance the statistical precision of beam range measurement. The accuracy of beam range verification is improved, within ~1.4 mm error, which is not achievable before applying the developed method. Conclusion: In this study, we tried to improve the statistics of the prompt gamma statistics by merging the prompt gamma distributions of multiple spots, and it was found that the merged distribution provided sufficient prompt gamma statistics and the proton beam range was determined accurately.

Fault Classification of a Blade Pitch System in a Floating Wind Turbine Based on a Recurrent Neural Network

  • Cho, Seongpil;Park, Jongseo;Choi, Minjoo
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.287-295
    • /
    • 2021
  • This paper describes a recurrent neural network (RNN) for the fault classification of a blade pitch system of a spar-type floating wind turbine. An artificial neural network (ANN) can effectively recognize multiple faults of a system and build a training model with training data for decision-making. The ANN comprises an encoder and a decoder. The encoder uses a gated recurrent unit, which is a recurrent neural network, for dimensionality reduction of the input data. The decoder uses a multilayer perceptron (MLP) for diagnosis decision-making. To create data, we use a wind turbine simulator that enables fully coupled nonlinear time-domain numerical simulations of offshore wind turbines considering six fault types including biases and fixed outputs in pitch sensors and excessive friction, slit lock, incorrect voltage, and short circuits in actuators. The input data are time-series data collected by two sensors and two control inputs under the condition that of one fault of the six types occurs. A gated recurrent unit (GRU) that is one of the RNNs classifies the suggested faults of the blade pitch system. The performance of fault classification based on the gate recurrent unit is evaluated by a test procedure, and the results indicate that the proposed scheme works effectively. The proposed ANN shows a 1.4% improvement in its performance compared to an MLP-based approach.

The Effect of VDT Work on Vision and Eye Symptoms among Workers in a TV Manufacturing Plant (텔레비젼(TV)생산업체 근로자들의 영상단말기(VDT)작업이 시력과 안증상에 미치는 영향)

  • Woo, Kuck-Hyeun;Choi, Gwang-Seo;Jung, Young-Yeon;Han, Gu-Wung;Park, Jung-Han;Lee, Jong-Hyeob
    • Journal of Preventive Medicine and Public Health
    • /
    • v.25 no.3 s.39
    • /
    • pp.247-268
    • /
    • 1992
  • This study was conducted to evaluate the effect of VDT work on eyes and vision among workers in a TV manufacturing plant. The study subjects consisted of 264 screen workers and 74 non-screen workers who were less than 40 years old male and had no history of opthalmic diseases such as corneal opacities, trauma, keratitis, etc and whose visual acuity on pre-employment health examination by Han's test chart was 1.0 or above. The screen workers were divided into two groups by actual time for screen work in a day : Group I, 60 workers, lesser than 4 hours a day and group II, 204 workers, more than 4 hours a day. From July to October 1992 a questionnaire was administered to all the study subjects for the general charateristics and subjective eye symptoms after which the opthalmologic tests such as visual acuity, spherical equivalent, lacrimal function, ocular pressure, slit lamp test, fundoscopy were conducted by one opthalmologist. The proportion of workers whose present visual acuity was decreased more than 0.15 in comparison with that on the pre-employment health examination by Han's test chart was 20.6% in Group II. 15.0% in Group I and 14.9% in non-screen workers. However, the differences in proportion were not statistically significant. The proportion of workers with decreased visual acuity was not associated with the age, working duration, use of magnifying glass and type of shift work (independent variables) in all of the three groups. However, screen workers working under poor illumination had a higher proportion of persons with decreased visual acuity than those working under adequate illumination (P<0.05) . The proportion of workers whose near vision was decreased was 27.5% in Group II, 18.3% in Group I, and 28.4% in non-screen workers and these differences in proportion were not statistically significant. Changes of near vision were not associated with 4 independent variables in all of the three groups. Six out of seven subjective eye symptoms except tearing were more common in Group I than in non-screen workers and more common in Group II than in Group I (P<0.01). Mean of the total scores for seven subjective symptoms of each worker(2 points for always, 1 point for sometimes, 0 point for never) was not significantly different between workers with decreased visual acuity and workers with no vision change. However, mean of the total scores for Group II was higher than those for the Group I and non-screen workers (P<0.01). Total eye symptom scores were significantly correlated with the grade of screen work, use of magnifying glass, and type of shift work. There was no independent variable which was correlated with the difference in visual acuity between the pre-employment health examination and the present state, the difference between far and near visions, lacrimal function, ocular pressure, and spherical equivalent. Multiple linear regression analysis for the subjective eye symptom scores revealed a positive linear relationship with actual time for screen work and shift work(P<0.01). In this study it was not observed that the VDT work decreased visual acuity but it induces subjective eye symptoms such as eye fatigue, blurred vision, ocular discomfort, etc. Maintenance of adequate illumination in the work place and control of excessive VDT work are recommended to prevent such eye symptoms.

  • PDF