• Title/Summary/Keyword: multiple switching

Search Result 404, Processing Time 0.022 seconds

Inplementation of Control System for multiple dimmable ballasts (집단 형광등의 조광제어기 구현)

  • Choi, Won-Ho;Park, Chong-Yeon;Kim, Nam-Tae
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.313-317
    • /
    • 2004
  • This paper shows the structure of a control System for Fluorescent fin Dimming Ballasts. The control system is composed of phase angle controller, a transducer, many dimmable ballasts. For the implementation of the control system, We made a controller and the transducer that transform the phase angle controlled signal into the DC level. we used the conventional dimmable ballast In this ballast, dimming control is achieved by varying the switching frequency that is controlled by the external DC level. This has non-linear illumination characteristics as the dimming control. Therefore we compensate characteristics using the transducer proposed in this paper. We measured the illumination of two FL-28 lamps with dimming controller.

  • PDF

Optimal Operation of Reactive Power Compensation Devices for Voltage Control of Emegency Status (비상상태 전압제어를 위한 무효전력보상설비의 최적 운용)

  • Ahn, Chang-Han;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.661-666
    • /
    • 2015
  • This paper proposes a method for solving running cost problem by minimizing switching reactive power compensation devices. An objective function was modeled by calculating the weighting value of cost, and a solution was derived using ILP. This paper suggests optimal coordinative control method between FACTS, Shunt Reactors, Capacitors and OLTC. Therefore, it is valuable for decision maker in determining order and capacity of devices which gaining a voltage stabilization. As a result, the objectives of voltage stabilization and cost minimization were achieved simultaneously. This realizes the economic efficiency of the system. We start by showing how to solve systems of linear equations using the language of pivots and tableaus. The effectiveness of this technique is demonstrated in modified PSS/E MIGUM 45 bus system. The simulation results show the effectiveness of this algorithm by comparing the outcome withseveral established methods.

Analysis of the soft handoff rate in DS-CDMA cellular systems (DS-CDMA 셀룰라 시스쳄에서의 소프트 핸드오프율에 대한 분석)

  • 조무호;김광식;조경록
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.8
    • /
    • pp.1659-1667
    • /
    • 1997
  • In DS-CDMA cellular systems, using the same frequency channel at the adjacent cells simultaneously makes soft handoff possible. In soft handoff, mobiles use multiple radio resources for the space diversity of signal in the overlapped region. The previous traffic models of hard handoff are not applicable to the system with soft handoff due to switching radio channels in that region. The handoff rate can be calculated by the mobility of mobiles, which is a function of the size and shape of a cell, and the speed and density of the mobiles. In this paper, we propose an analytical traffic model to study the soft handoff rate. We assume that the system uses a two-way handoff scheme for practical purposes, which connects only two cells to a mobile during soft handoff. We performed a computer simulation to confirm the accuracy of the proposed soft handoff model. The simulation results show good agreement with the analytical model.

  • PDF

A Study on the stability improvement of current-mode controlled DC-DC Converter (전류제어형 DC-DC컨버터의 안정도 향상에 관한 연구)

  • Kim, Cherl-Jin;Song, Yo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.365-367
    • /
    • 2000
  • Recently, the power supply equipments have tendency to take multiple feedback loop paths. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$ is nearly 1/5 of switching frequency $f_s$ from the experimental result with frequency response analyzer.

  • PDF

A Study on the Parallel Operation of a Front-end-converter for a High Speed Electric Traction Drive (고속전철 4상한 입력 컨버터 병렬 운전에 관한 연구)

  • Ryoo, Hong-Je;Woo, Myung-Ho;Kim, Jong-Soo;Kim, Won-Ho;Rim, Geun-Hie;Gopakumar, K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.121-124
    • /
    • 1998
  • Front end AC to DC converters of the boost type are used in traction applications for generating the DC link for the inverters. A GTO based converter is usually switched with a switching frequency of 300 to 500Hz, resulting in low frequency harmonic problems. In order to avoid this, multiple converters with Phase shifted carrier waveforms are used to suppress the low frequency harmonics. A detailed study of an AC to DC converter, with two converters parallely operated with Phase shifted carrier wave farms is Presented in this paper.

  • PDF

Stabilization of Switched Linear Systems (선형 스위칭 시스템의 안정화)

  • Yeom, Dong-Hae;Im, Ki-Hong;Choi, Jin-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.05a
    • /
    • pp.13-15
    • /
    • 2004
  • In this paper, we propose a novel stability criterion and a guideline of controller design for switched linear systems. Unlike existing criterions such as Lie algebraic method and multiple Lyapunov functions method, the proposed criterion can be applied to each individual system without considering an overall system. By applying the proposed criterion to each individual system separately, a state feedback controller can be easily designed. Stability of the overall system is proved by developing a rule to determine non-increasing Lyapunov functions recursively at each switching instant. An illustrative example is given.

  • PDF

Vertical Handoff Decision Algorithm combined Improved Entropy Weighting with GRA for Heterogeneous Wireless Networks

  • Zhao, Shasha;Wang, Fei;Ning, Yueqiang;Xiao, Yi;Zhang, Dengying
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.11
    • /
    • pp.4611-4624
    • /
    • 2020
  • Future network scenario will be a heterogeneous wireless network environment composed of multiple networks and multimode terminals (MMT). Seamless switching and optimal connectivity for MMT among different networks and different services become extremely important. Here, a vertical handoff algorithm combined an improved entropy weighting method based on grey relational analysis (GRA) is proposed. In which, the improved entropy weight method is used to obtain the objective weights of the network attributes, and GRA is done to rank the candidate networks in order to choose the best network. Through simulation and comparing the results with other vertical handoff decision algorithms, the number of handoffs and reversal phenomenon are reduced with the proposed algorithm, which shows a better performance.

Heat Load Estimation-Based Switching Explicit Model Predictive Temperature Control for VRF Systems (시스템 에어컨의 온도 제어를 위한 부하 예측 기반 스위칭 모델 예측 제어)

  • Jun-Yeong Kim;S.M. Lee
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.19 no.3
    • /
    • pp.123-130
    • /
    • 2024
  • This paper proposes an EMPC (Explicit Model Predictive Controller) for temperature tracking control based on heat load prediction by an ESO (Extended State Observer) for a variable cooling circulation system with multiple indoor units connected to one outdoor unit. In this system, heat transfer and heat loss relative to the input temperature are modeled using system dynamics. Using this model, we design an EMPC based on an ESO that is robust to temperature changes and depends on airflow. To determine the stability of both the controller and the observer, asymptotic stability is verified through Lyapunov stability analysis. Finally, to validate the performance of the proposed controller, simulations are conducted under three scenarios with varying airflow, set temperature, and heat load.

Design of Dual-Polarization Antenna with High Cross-Polarization Discrimination (높은 교차편파 분리도를 가지는 이중편파 안테나 설계)

  • Lee, Sang-Ho;Oh, Taeck-Keun;Ha, Jung-Je;Lee, Yong-Shik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.199-205
    • /
    • 2017
  • In a small cell base station used in densely populated areas, a dual polarized multiple antenna(MIMO) is mainly used to increase the cell capacity. This paper demonstrates a dual-polarization antenna with high cross-polarization discrimination(XPD) that can improve the capacity of a small cell using a dual polarization multiple antenna (MIMO). By using the symmetric structure and differential feeding, high XPD in all directions is achieved. In addition, a very similar radiation pattern is observed between each polarization. Because of high XPD and similar radiation pattern in all directions, proposed antenna is well adopted for small-cell multiple-input multiple-output(MIMO) system. Experimental results shows that the proposed antenna has a bandwidth of 180 MHz (2.51~2.7 GHz), a maximum gain of 4.5 dBi (3.5~4.5 dBi), and a half-power beam width of 85 degrees. In addition, average XPD of 26.4 dB in all directions, more than 13.8 dB increase than previous dual-polarization antennas which use single emitter by using different feeding or selectively use polarization through switching.

An Analysis of the Economic Effects of the Pilot Project for Multiple-Purpose Utilization of Paddy Fields Focusing on Income and Welfare Changes (소득 및 후생 변화를 통한 농지범용화 시범사업의 경제적 효과 분석)

  • Lim, Che hwan;Ha, Yong hyun;Kim, Do hoon;An, Dong hwan;Yi, Hyang mi;Kim, Kwansoo
    • Journal of Korean Society of Rural Planning
    • /
    • v.28 no.2
    • /
    • pp.71-85
    • /
    • 2022
  • The food self-sufficiency rate of agricultural products in Korea, excluding rice, is around 20%, and the government is promoting various policies including a Multiple-Purpose Utilization of Paddy Fields project, to increase the self-sufficiency rate of major grains. The project for Multiple-Purpose Utilization of Paddy Fields is being promoted as a part of a program to create farmland infrastructure to facilitate the cultivation of crops other than rice in rice paddies, and pilot projects were started in four regions in 2020. The purpose of this study is to analyze the economic effects of the pilot project for Multiple-Purpose Utilization of Paddy Fields, and to propose policies to increase the effectiveness of the project. In order to analyze the economic effect, we estimated the change in farm income generated by switching from rice to other crops, and measured the effect of welfare change using the Equilibrium Displacement Model (EDM). As a result of the analysis, social welfare is expected to increase when the pilot project for Multiple-Purpose Utilization of Paddy Fields is implemented, and the income of the beneficiary farmers is also expected to improve compared to that of single-cropping when double-cropping is implemented. However, it was found that the economic feasibility of the project differs depending on the crops converted. Juksan-myeon, Gimje-si, which is an area where soybean production was successful, was analyzed from the viewpoint of increasing the economic feasibility of the pilot project. Their success factors were analyzed into four major factors: infrastructure, farming methods, education, and collaboration with local agricultural organizations. If such a success story can be utilized in the future project implementation process, it can contribute to the improvement of farm household income and national economic welfare.