• Title/Summary/Keyword: multiple measurements

Search Result 803, Processing Time 0.028 seconds

Accuracy Enhancement using Network Based GPS Carrier Phase Differential Positioning (네트워크 기반의 GPS 반송파 상대측위 정확도 향상)

  • Lee, Yong-Wook;Bae, Kyoung-Ho
    • Spatial Information Research
    • /
    • v.15 no.2
    • /
    • pp.111-121
    • /
    • 2007
  • The GPS positioning offer 3D position using code and carrier phase measurements, but the user can obtain the precise accuracy positioning using carrier phase in Real Time Kinematic(RTK). The main problem, which RTK have to overcome, is the necessary to have a reference station(RS) when using RTK should be generally no more than 10km on average, which is significantly different from DGPS, where distances to RS can exceed several hundred kilometers. The accuracy of today's RTK is limited by the distance dependent errors from orbit, ionosphere and troposphere as well as station dependent influences like multipath and antenna phase center variations. For these reasons, the author proposes Network based GPS Carrier Phase Differential Positioning using Multiple RS which is detached from user receiver about 30km. An important part of the proposed system is algorithm and software development, named DAUNet. The main process is corrections computation, corrections interpolation and searching for the integer ambiguity. Corrections computation of satellite by satellite and epoch by epoch at each reference station are calculated by a Functional model and Stochastic model based on a linear combination algorithm and corrections interpolation at user receiver are used by area correction parameters. As results, the users can obtain the cm-level positioning.

  • PDF

A PHOTOELASTIC STRESS ANALYSIS OF FIXED PARTIAL DENTURES WITH ENDOPOREIMPLANTS ACCORDING TO SPLINTING, CONTACT TIGHTNESS, AND CROWN LENGTH (연결고정, 인접면 접촉강도 및 치관길이에 따른 엔도포어 임플란트를 이용한 고정성 국소의치의 광탄성 응력 분석)

  • Jeong, Hoe-Yeol;Choi, Min-Ho;Kim, Yu-Lee;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.425-442
    • /
    • 2004
  • Statement of problem: A difficulty in achieving a passive-fitting prosthesis can be overcome by individual crown restoation of multiple implants. But individualized crown has another difficulty in control of contact tightness and stress distribution. Purpose: This in vitro study is to evaluate the stress distribution and the magnitude in the supporting tissues around Endopore implants with different crown lengths, interproximal contact tightness, and the splinting effects. Material & methods: Three Endopore implants($4.1{\times}9mm$) were placed in the mandibular posterior edentulous area distal to the canine and photoelastic model was made with PL-2 resin(Measurements Group, Raleigh, USA). Restorations were fabricated in two crown lengths: 9, 13 mm. For non-splinted restorations, individual crowns were fabricated on three custom-milled titanium abutments. After the units were cemented, 4 levels of interproximal contact tightness were evaluated: open, ideal($8{\mu}m$ shim stock drags without tearing), medium($40{\mu}m$), and heavy($80{\mu}m$). For splinted restorations, 3-unit fixed partial dentures were fabricated. This study was examined under simulated non-loaded and loaded conditions(6.8 kg). Photoelastic stress analysis was carried out to measure the fringe order around the implant supporting structure. Results: 1. When restorations were not splinted, the more interproximal contact tightness was increased among the three implants, the more stress was shown in the cervical region of each implant. When crown length was increased, stresses tended to increase in the apex of implants but there were little differences in stress fringes. 2. When nonsplinted restorations were loaded on the first or third implant, stresses were increased in the apex and cervical region of loaded implant. Regardless of interproximal contact tightness level, stresses were not distributed among the three implants. But with tighter interproximal contact, stresses were increased in the cervical region of loaded first or third implant. 3. When the nonsplinted restorations were not loaded, there were little stresses on the supporting structure of implants, but low level stresses were shown in the splinted restorations even after sectioning and soldering. 4. With splinted restorations, there were little differences in stresses between different crown lengths. When splinted restorations were loaded, stresses were increased slightly on the loaded implant, but relatively even stress distribution occurred among the three implants. Conclusions: Splinting the crowns of adjacent implants is recommended for Endopore implants under the overloading situation.

Evaluation of Methods Used in the Calculation of Condition Index Using the Mussel, Mytilus coruscus (Gould, 1861) Collected from Chuja Island, Cheju, Korea (추자도산 홍합, Mytilus coruscus (Gould, 1861) 의 Condition Index 산정에 대한 연구)

  • 강도형;최광식
    • The Korean Journal of Malacology
    • /
    • v.15 no.1
    • /
    • pp.57-62
    • /
    • 1999
  • Condition indices (Cl) are considered to be useful measurements of the nutritive and health status of bivalves although studies on Cl of bivalves are limited due to the lack of a standard formula for calculating Cl. This study attempts to generate Cl of the mussel, Mytilus coruscus inhabiting along the coastal area of Chuja Island in Cheju using three primary formulas. the formulas used in this study: (1) Cl-vol= [tissue dry weight (g) 1000] /shell cavity volume (ml). (2) Cl-wt= [tissue dry weight (g) 1000] / internal shell cavity capacity (g). (3) Cl-size= tissue wet weight (g)/[shell length (mm)]$\^$3/. Monthly condition indices calculated with the three formulas are compared using ANOVA, Duncan's multiple range test and Pearson correlation coefficient. In Chuja Island M. coruscus collected ranged from 50 to 180 mm in shell length. Monthly ranges of Cl-values were 67.48 to 140.61 (Cl-vol), 74.67 to 118.02 (Cl-wt) and 1.4 10$\^$-5) to 1.6 10$\^$-5/ (Cl-size). Cl-vol values in August were higher than two Cl-values in the other months. Monthly Cl-vol was significantly different from Cl-wt and Cl-size. (p<0.05). The results of this study suggest that volumetric condition index (Cl-vol) used in this study is acceptable as a standard measure to evaluate conditions of M. coruscus.

  • PDF

Changes in Body Surface Lines Caused By Lower Limb Movements in Designing Slacks (II) (슬랙스 설계를 위한 하지동작에 따른 체표선 변화 2)

  • Cho Sung-Hee
    • Korean Journal of Human Ecology
    • /
    • v.7 no.3
    • /
    • pp.35-48
    • /
    • 2004
  • In this study, by determining lower limb movements which cause significant changes in body surface lines, body parts with the greatest maximum expansion and contraction rate respectively were illustrated in descending order. Using unmarried female university students aged 18 - 24 as subjects, a total of 32 body surface categories (15 body surface lines and 17 body surface segment lines) were measured in one static and 9 movement poses. In particular, expansion and contraction levels and rates were measured and used in the analysis. The analysis first involved the calculation of the average measurement per body part in body surface line in static pose as well as of the average expansion and contraction levels and rates in 9 lower limb movements. Two-way MANOVA and multiple comparison analysis (Tukey) were conducted on movements and individual somatotypes regarding measurement per body part and expansion and contraction rates. Movements which cause measurements of body surface lines differed significantly in body surface line in static pose versus in movement were then identified. Among average expansion and contraction rates in such movements, maximum average expansion and contraction levels, maximum average expansion and contraction rate, and classes of expansion and contraction rate were determined per body part. The results of this study are as follows. First, 5 lower limb movements; F2, F5, F6, F7, F8, which caused significant changes in body surface lines were determined and illustrated in table 4. Second, the levels, rates, and classes of expansion and contraction rate per body part are illustrated in Tables 5 and 6. Body parts with the greatest maximum expansion rate were, in descending order: upper segment of center back leg line, upper segment of inner leg line, middle segment of center front leg line, posterior crotch length, anterior knee girth, anterior thigh girth, center back leg line, girth at crotch height, anterior midway thigh girth, hip girth, anterior crotch length, knee girth, waist girth, inner leg line, thigh girth, and crotch length. Those with the greatest maximum contraction rate were, in descending order: anterior crotch length, upper segment of center front leg line, lower segment of center back leg line, center front leg line, and posterior thigh girth. The maximum expansion rates and maximum contraction rates, which ranged from 2.05 to $35.95\%$ and from -0.20 to $-30.16\%$ respectively, were classified per body part into 4 ABCD classes. The body part with maximum expansion was the upper segment of the center back leg line at vertical body surface line, expanding by $35.95\%$ or 16.03cm in F5 flexion movement. In contrast, the body part with maximum contraction was the anterior crotch length at vertical body surface line, contracting by $-30.16\%$ or -10.54cm in F5 flexion movement. Both, however, were the body parts to expand or contract the most among all horizontal and vertical body surface lines.

  • PDF

A Review of Time Series Analysis for Environmental and Ecological Data (환경생태 자료 분석을 위한 시계열 분석 방법 연구)

  • Mo, Hyoung-ho;Cho, Kijong;Shin, Key-Il
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.4
    • /
    • pp.365-373
    • /
    • 2016
  • Much of the data used in the analysis of environmental ecological data is being obtained over time. If the number of time points is small, the data will not be given enough information, so repeated measurements or multiple survey points data should be used to perform a comprehensive analysis. The method used for that case is longitudinal data analysis or mixed model analysis. However, if the amount of information is sufficient due to the large number of time points, repetitive data are not needed and these data are analyzed using time series analysis technique. In particular, with a large number of data points in the current situation, when we want to predict how each variable affects each other, or what trends will be expected in the future, we should analyze the data using time series analysis techniques. In this study, we introduce univariate time series analysis, intervention time series model, transfer function model, and multivariate time series model and review research papers studied in Korea. We also introduce an error correction model, which can be used to analyze environmental ecological data.

Practical modeling of cigarette ventilation rate

  • Kim, Young-Hoh;Lee, Moon-Yong;Rhee, Kyu-Seo;Lee, Dong-Wook
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.21 no.2
    • /
    • pp.109-118
    • /
    • 1999
  • A model predicted describing the effect of cigarette making materials on the level of filter ventilation was developed and evaluated. The developed model was expressed in terms of a linear and quadratic relationship which was validated with experimental measurements for different porosity of plug wrap and tipping paper, unencapsulated pressure drop of filter plug and cigarette column and vent position. Forty-six experimental frequencies were determined as a result of using three levels with five factors Box-Behnken design and analyzed by the multiple regression analysis with backward stepwise in STATISTICA/PC under restricted conditions. The four factors, except filter pressure drop variable, were statistically significant at the level of 0.05 but most of all linear by linear interactions were comparatively lower significant. By the analysis of linear and quadratic regression coefficient, filter ventilation of the cigarette was affected by porosity of plugwrap (5.87, -4.25), porosity of tip paper (5.68, -1.00), vent position (-3.87, 3.08), tobacco column pressure drop (2.56, 0.66), and filter pressure drop (1.50, 0.58) in the decreasing order. It should be emphasized that the major conclusion of this study was not that any particular parameter was linear or quadratic on any limit scale, but that there were highly significant relationships among factors involving linear, quadratic and their interaction and perhaps even linearity between and within factors. While, there is also quite strong evidence that vent position from mouth end and cigarette making materials are reverse relationship on this experimental model. On the basis of the result, it can be concluded that the porosity of the plug wrap and tipping paper has a marked effect on degree of filter ventilation rate. The F-value of plug wrap and tipping paper porosity among five factors were 39.2 and 36.8 respectively with P-value of 0.000 indicating higher significant for both factors. According to the analysis of variance, the model fitted for filter ventilation was significant at 5% confidence level and the coefficient of determination ($R^2$=0.84) was the proportion to variability in the data well fitted for by the model.

  • PDF

Relationship of soil profile strength and apparent soil electrical conductivity to crop yield (실시간 포장에서 측정한 토양 경도 및 전자장 유도 전기전도도와 작물수량과의 관계)

  • Jung, Won-Kyo;Kitchen, Newell R.;Sudduth, Kenneth A.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.2
    • /
    • pp.109-115
    • /
    • 2006
  • Understanding characteristics of claypan soils has long been an issue for researchers and farmers because the high-clay subsoil has a pronounced effect on grain crop productivity. The claypan restricts water infiltration and storage within the crop root zone, but these effects are not uniform within fields. Conventional techniques of identifying claypan soil characteristics require manual probing and analysis which can be quite expensive; an expense most farmers are unwilling to pay. On the other hand, farmers would be very interested if this information could be obtained with easy-to-use field sensors. Two examples of sensors that show promise for helping in claypan soil characterization are soil profile strength sensing and bulk soil apparent electrical conductivity (ECa). Little has been reported on claypan soils relating the combined information from these two sensors with grain crop yield. The objective of this research was to identify the relationships of sensed profile soil strength and soil EC with nine years of crop yield (maize and soybean) from a claypan soil field in central Missouri. A multiple-probe (five probes on 19-cm spacing) cone penetrometer was used to measure soil strength and an electromagnetic induction sensor was used to measure soil EC at 55 grid site locations within a 4-ha research field. Crop yields were obtained using a combine equipped with a yield monitoring system. Soil strength at the 15 to 45 cm soil depth were significantly correlated to crop yield and ECa. Estimated crop yields from apparent electrical conductivity and soil strength were validated with an independent data set. Using measurements from these two sensors, standard error rates for estimating yield ranged from 9 to 16%. In conclusion, these results showed that the sensed profile soil strength and soil EC could be used as a measure of the soil productivity for grain crop production.

Electrochemical Properties of Kaolinite in Aqueous Suspension (수용액중(水溶液中)에서의 Kaolinite 입자(粒子)의 전기화학적(電氣化學的) 성질(性質))

  • Lim, Hyung-Sik;Baham, J.;Volk, V.V.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.16 no.4
    • /
    • pp.318-324
    • /
    • 1983
  • Electrochemical properties of Georgia kaolinite in aqueous suspension were studied by ion adsorption, potentiometric titration, and electrophoretic mobility measurements. Kaolinite in 0.001 M and 0.1 M NaCl solution showed qualitatively both pH independent and pH depender negative and positive charges through pH range 2.5-11.0 when dissolved aluminum ions from kaolinite were considered as well as $Na^+$ and $Cl^-$ as index ions. Electrophoretic mobilities (EM) of 0.02 wt. % kaolinite suspension in distilled water and 0.001 M NaCl solution were approximately constant against mobility measuring time consumed in the electrophoresis cell at different pH values, and isoelectric points(IEP) were around pH 4.7. EM values in 0.1 M NaCl solution were positive and constant against mobility measuring time below pH 4; but above pH 4, EM values were negative for the first 10 seconds followed by positive values which became approximately constant through stepped changes after 10 minutes. Hydrated cations may bind to the six- member oxygen ring sites having multiple partial negative charges on the exterior tetrahedral layer surface by both electrostatic and hydrogen bonding force while hydrated anions bind to the partially positively charged hydrogen atoms on the exterior octahedral layer surface. Parts of the aluminol groups on the exterior octahedral layer surface as well as edge faces may be involved in complex reactions and have both anion and cation exchange capacities in the electrolyte solution above pH 4.

  • PDF

Estimation of Environmental Performance in 29 Chinese Provinces - Focused on Integrated Pollution Intensity - (중국 29개 성의 환경성과 평가 - 통합오염원 단위를 중심으로 -)

  • Kim, Kwang-Uk;Piao, Huilan-Lan;Kang, Sang-Mok
    • Journal of Environmental Policy
    • /
    • v.10 no.1
    • /
    • pp.71-91
    • /
    • 2011
  • The purpose of this paper is to estimate the environmental performance of 29 Chinese provinces by adopting the advanced measurements, integrated pollution intensity index, IPI, which can be computed using Data Envelopment Analysis(DEA) techniques. This index has the advantage of accounting for multiple resources used, good outputs produced and pollutants emitted simultaneously. The result obtained using the methodology shows the obvious evidence that provinces located around eastern area of China take relatively low levels and these phenomenons have been clearly observed throughout the sample period 1998~2007. The estimated index can be interpreted that the environmental burden in China has been steadily decreased as economic growth. This paper also tries to figure out the relationship among IPI, income levels, economic structures, the level of environmental regulations and FDI inflow. The estimated relationship between IPI and income per capita predicts improving environmental performance with increasing income levels. This explains the improvement in IPI which is simultaneously observed with income increases. According to the 'pollution haven hypothesis', many researches have been concerned the possibility that a large amount of foreign capital has been invested in China to avoid the strict environmental standards in advanced countries. However, the estimated coefficients in all model specifications take negative sign with IPI and highly statistical significant. This is a indication that there are positive impacts of foreign investments on IPI by adopting clean and high technologies from advanced countries.

  • PDF

Anthropometric Study of the Stomach

  • Lee, Eun-Gyeong;Kim, Tae-Han;Huh, Yeon-Ju;Suh, Yun-Suhk;Ahn, Hye-Sung;Kong, Seong-Ho;Lee, Hyuk-Joon;Kim, Woo Ho;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.16 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Purpose: The aim of this study was to establish an anthropometric reference of the stomach for gastric cancer surgery and a modeling formula to predict stomach length. Materials and Methods: Data were retrieved for 851 patients who underwent total gastrectomy at the Seoul National University Hospital between 2008 and 2013. Clinicopathological data and measurements from a formalin-fixed specimen were reviewed. The lengths (cm) of the greater curvature (GC) and lesser curvature (LC) were measured. Anthropometric data of the stomach were compared according to age, body weight, height (cm), and body mass index. To predict stomach length, two multiple regression analyses were performed. Results: The mean lengths of the GC and LC were $22.2{\pm}3.1cm$ and $16.3{\pm}2.6cm$, respectively. The men's GC length was significantly greater than the women's ($22.4{\pm}3.1cm$ vs. $21.2{\pm}2.9cm$, P=0.003). Patients aged >70 years showed significantly longer LC than those aged <50 years ($16.9{\pm}2.9cm$ vs. $15.9{\pm}2.4cm$, P=0.002). Patients with body weights >70 kg showed significantly longer GC than those with body weights <55 kg ($23.0{\pm}2.9cm$ vs. $21.4{\pm}3.2cm$, P<0.001). In the predicted models, 4.11% of the GC was accounted for by age and weight; and 4.94% of the LC, by age, sex, height, and weight. Conclusions: Sex, age, height, and body weight were associated with the length of the LC, while sex and body weight were the only factors that were associated with the length of the GC. However, the prediction model was not sufficiently strong.