• 제목/요약/키워드: multiple defects

Search Result 308, Processing Time 0.032 seconds

Arterial or venous free flaps for volar tissue defects of the proximal interphalangeal joint: A comparison of surgical outcomes

  • Choi, Min Suk;Roh, Si Young;Koh, Sung Hoon;Kim, Jin Soo;Lee, Dong Chul;Lee, Kyung Jin;Hong, Min Ki
    • Archives of Plastic Surgery
    • /
    • v.47 no.5
    • /
    • pp.451-459
    • /
    • 2020
  • Background For volar soft tissue defects of the proximal interphalangeal (PIP) joint, free flaps are technically challenging, but have more esthetic and functional advantages than local or distant flaps. In this study, we compared the long-term surgical outcomes of arterial (hypothenar, thenar, or second toe plantar) and venous free flaps for volar defects of the PIP joint. Methods This was a single-center retrospective review of free flap coverage of volar defects between the distal interphalangeal and metacarpophalangeal joint from July 2010 to August 2019. Patients with severe crush injuries (degloving, tendon or bone defects, or comminuted/intra-articular fractures), thumb injuries, multiple-joint and finger injuries, dorsal soft tissue defects, and defects >6 cm in length were excluded from the study, as were those lost to follow-up within 6 months. Thirteen patients received arterial (hypothenar, thenar, or second toe plantar) free flaps and 12 received venous free flaps. Patients' age, follow-up period, PIP joint active range of motion (ROM), extension lag, grip-strength ratio of the injured to the uninjured hand, and Quick Disabilities of Arm, Shoulder & Hand (QuickDASH) score were compared between the groups. Results Arterial free flaps showed significantly higher PIP joint active ROM (P=0.043) and lower extension lag (P =0.035) than venous free flaps. The differences in flexion, grip strength, and QuickDASH scores were not statistically significant. Conclusions The surgical outcomes of arterial free flaps were superior to those of venous free flaps for volar defects of the PIP joint.

Multiple Ocular Defects in a Cat (고양이의 다발성 안 기형 1례)

  • Kim, Won-Tae;Park, Shin-Ae;Jeong, Man-Bok;Yi, Na-Young;Kim, Se-Eun;Chae, Je-Min;Kang, Min-Su;Kim, Dae-Yong;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.640-643
    • /
    • 2007
  • A 3-month-old female mixed breed cat was referred to the veterinary medical teaching hospital of Seoul National University with ocular discharge and blepharospasm of both eyes. On ophthalmic examination, the patient was diagnosed as multiple ocular defects : eyelid coloboma, keratoconjunctivitis sicca, persistent pupillary membrane, uveal cyst, incipient cataract and choroidal hypoplasia. On histopathologic examination, choroidal hypoplasia was confirmed.

An Efficient Diagnosis Algorithm for Multiple Stuck-at Faults (다중 고착 고장을 위한 효율적인 고장 진단 알고리듬)

  • Lim Yo-Seop;Lee Joo-Hwan;Kang Sung-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.9 s.351
    • /
    • pp.59-63
    • /
    • 2006
  • With the increasing complexity of VLSI devices, more complex faults have appeared. Many methods for diagnosing the single stuck-at fault have been studied. Often multiple defects on a foiling chip better reflect the reality. So, we propose an efficient diagnosis algorithm for multiple stuck-at faults. By using vectorwise intersections as an important metric of diagnosis, the proposed algorithm can diagnose multiple defects using single stuck-at fault simulator. In spite of multiple fault diagnosis, the number of candidate faults is also drastically reduced. For fault identification, positive calculations and negative calculations based on variable weights are used for the matching algorithm. Experimental results for ISCAS85 and full-scan version of ISCAS89 benchmark circuits prove the efficiency of the proposed algorithm.

Coating defects in polymer-coated drug-eluting stents

  • Bedair, Tarek M.;Cho, Youngjin;Park, Bang Ju;Joung, Yoon Ki;Han, Dong Keun
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.1 no.3
    • /
    • pp.131-150
    • /
    • 2014
  • Vascular stenting has a great attention as a treatment for coronary arteries diseases as compared with percutaneous balloon angioplasty. In-stent restenosis and thrombosis are side effects resulting from using bare metal stent (BMS). Employing platelet therapy allowed to reduce the rate of thrombosis, however, the rate of restenosis remains a major problem. In 2002, drug-eluting stents (DESs) were introduced as an effort to reduce the restenosis. The commercially available DESs continue to suffer from coating defects that might lead to a series of adverse effects. Most importantly, multiple concerns remain regarding the polymer coating integrity on metal surfaces or the relation of polymer irregularities to longterm adverse events.

Development and Utilization of Manufacturing Technique for Large Steel Casting (대형 주강품의 제조기술 개발과 실용화)

  • Tsumura, Osamu;Yoshimoto, Kazuo;Yamakuro, Sigeru
    • Journal of Korea Foundry Society
    • /
    • v.24 no.2
    • /
    • pp.63-70
    • /
    • 2004
  • Foundry techniquews for large steel casting depends on the skills of foundrymen considerably. Especially, the problem of reducing casring surface defects is difficult to clear numerically. Statistical analysis by using wuantification theory for hot tear and sand inclusion, and multiple regression analysis for dimensional defects have been shown to be examples of solving this difficulty. Many causes of surface defects can be evaluated by these analyses. These evaluations serve as the base data of defect reduction and contribute to the constant improvement of casting quality and quality enhancement activity. The system to perform quality enhancement activity was developed and it proved very useful for transfering foundry techniques and skills from the old to young generations.

Properties of Silicon for Photoluminescence

  • Baek, Dohyun
    • Applied Science and Convergence Technology
    • /
    • v.23 no.3
    • /
    • pp.113-127
    • /
    • 2014
  • For more than five decades, silicon has dominated the semiconductor industry that supports memory devices, ICs, photovoltaic devices, etc. Photoluminescence (PL) is an attractive silicon characterization technique because it is contactless and provides information on bulk impurities, defects, surface states, optical properties, and doping concentration. It can provide high resolution spectra, generally with the sample at low temperature and room-temperature spectra. The photoluminescence properties of silicon at low temperature are reviewed and discussed in this study. In this paper, silicon bulk PL spectra are shown in multiple peak positions at low temperature. They correspond with various impurities such as In, Al, and Be, phonon interactions, for example, acoustical phonons and optical phonons, different exciton binding energies for boron and phosphorus, dislocation related PL emission peak lines, and oxygen related thermal donor PL emissions.

A case of congenital cloacal exstrophy/omphalocele-exstrophy-imperforate anus-spinal defects syndrome and a successful pregnancy

  • Seat, Mara;Boxwalla, Munira;Hough, Arielle;Goodwin, Glenn
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.3
    • /
    • pp.215-218
    • /
    • 2022
  • Herein, we report an exceptionally rare case of a 25-year-old woman with cloacal exstrophy/omphalocele-exstrophy-imperforate anus-spinal defects (OEIS) syndrome achieving a viable pregnancy despite many gastrointestinal and genitourinary malformations and multiple respective corrective operations. The patient was born with two vaginas, two uteruses, four ovaries, an imperforate anus, a large omphalocele including bowel and bladder exstrophy, and diaphysis of the pubic rami. This patient is the only documented OEIS patient not to have tethered spinal cord as an anomaly, perhaps contributing to her successful pregnancy. After experiencing preeclampsia with severe features at 35 weeks, the baby was born via cesarean section.

The White Blood Cell Count to Hemoglobin Level Ratio is Correlated with the Presence of Cortical Defects on DMSA Renal Scans in Children with Febrile Urinary Tract Infection

  • Jin, Bo Kyeong;Baek, Kyung Suk;Rhie, Seon Kyeong;Lee, Jun Ho
    • Childhood Kidney Diseases
    • /
    • v.22 no.2
    • /
    • pp.42-46
    • /
    • 2018
  • Purpose: We investigated whether the white blood cell (WBC) count to hemoglobin (Hgb) level ratio is correlated with the presence of cortical defects on dimercaptosuccinic acid (DMSA) renal scan in children with febrile urinary tract infection (UTI). Methods: We examined 95 children who were consecutively admitted to our hospital with their first episode of febrile UTI. Blood tests (C-reactive protein [CRP], WBC, Hgb] were performed. All enrolled children underwent DMSA scanning during admission. Data were compared between children with positive and negative DMSA results. The correlations between WBC to Hgb ratio and the presence of cortical defects on DMSA scan, and between WBC to Hgb ratio and CRP level were analyzed using the Pearson chi-squared test. Multiple logistic regression analysis was used to evaluate whether WBC to Hgb ratio could predict the cortical defects on DMSA scan in children with febrile UTI. Results: The WBC to Hgb ratio was significantly higher in children with positive DMSA results than in those with negative DMSA results; positively correlated with the presence of cortical defects on DMSA scan and CRP; and was a significant factor for predicting the presence of cortical defects on DMSA scan. Conclusion: The WBC to Hgb ratio may predict the presence of cortical defects on acute DMSA scans in children with febrile UTI.

The Variation of Stress Concentration Factor and Crack Initiation Behavior on the Hole Defects Around the Rivet Hole in a Aircraft Materials (항공재료 리벳홀에 인접한 원공결함의 위치에 따른 응력집중계수의 변화와 균열발생거동)

  • Song, Sam-Hong;Kim, Cheol-Woong;Kim, Tae-Soo;Hwang, Jin-Woo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.381-388
    • /
    • 2003
  • The material deficiencies in the form of pre-existing defects can initiated cracks and fractures. The stress distribution and fatigue crack initiation life of engineering materials may be associated with the size, the shape and the relative location of defects contained in the component. The objective of this study is to investigate the effect of arbitrarily located hole defect around the rivet hole of a wing section in monolithic aluminum and Al/GFRP laminates under cyclic bending moment during a service load. The stress distribution and the fatigue crack initiation behavior near a rivet hole of on the relationships between stress concentration factor ($K_t$) and relative position of defects were considered. The test results indicated the features of different stress field. Therefore, the stress concentration factor ($K_t$) and the fatigue crack initiation behavior was illustrated different behavior according to each position of hole defect around the rivet hole in monolithic aluminum and Al/GFRP laminates.

  • PDF

Buckling of cylindrical shells under external pressure proposition of a new shape of self-stiffened shell

  • Araar, M.;Jullien, J.F.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.4
    • /
    • pp.451-460
    • /
    • 1996
  • We propose a new shape of cylindrical shell formed by multiples vaults which gives a self-stiffening against buckling. By an experimental and numerical study of cylindrical shells with a repeated defect, on the circumferential direction made only of outside oriented wave-defects, we show that multiple vault cylindrical shells can have a good behaviour in buckling. An optimal behaviour is obtained by optimization of the vaults number, with conduces to a special multiple vault cylindrical shell named "ASTER shell".