• 제목/요약/키워드: multi-story buildings

검색결과 118건 처리시간 0.021초

건축분야에서의 스토리텔링 기법 활용방안 연구 (A Research on the Uses of Storytelling Approach for Architecture)

  • 윤기병
    • 한국주거학회논문집
    • /
    • 제18권1호
    • /
    • pp.53-60
    • /
    • 2007
  • Storytelling approach is the way to formulate and solve problems using stories. Story is a means to understand and react everyday life that can be regarded as multi-dimensional problems. The approach becomes popular in various fields in conjunction with digital technology. In particular, it is used to solve problems in relation to whole context. In design, storytelling approach is used to clarify design constraints. It can be used to clarify and communicate thoughts for design artifacts, and to understand how the artifacts might be used in particular circumstances. In particular, the approach is useful to use under uncertain circumstances. In architecture, storytelling approach can be used in the area of design generation, design critique and capturing design knowledge. In design generation, it can be used to describe and formulate design experiences rather than simple designing artifacts. The approach formalizes design based on stories of user experiences. Digital technology such as virtual reality can be used to experience designed spaces for design modifications. In design critique area, it can be used to fill uncertain facts for historical buildings as welt as different from present status. Such stories can be used to build digital modeling and used to open criticism. Stories can be used to formalize knowledge in architectural domain as a form of implicit knowledge for certain projects. In architecture, it often is required to design types of environment never experienced before as well as to accomodate fast changing technologies. Storytelling methodology can be used as a method to cope with uncertainty and complexity in design requirements along with accumulating design knowledge.

강성 및 감쇠 비대칭 구조물의 모드 특성 (Modal Characteristics of a Structure with Stiffness and Damping Eccentricit)

  • 김진구;방성혁
    • 한국전산구조공학회논문집
    • /
    • 제15권3호
    • /
    • pp.421-432
    • /
    • 2002
  • 본 연구에서는 진동제어를 목적으로 강성이 평면에서 비대칭적으로 분포된 구조물에 감쇠기를 설치할 경우 감쇠편심과 강성편심에 따른 모드특성 및 변위응답의 변화에 관하여 연구하였다 모드 특성으로는 고유진동수, 모드 감쇠비, 모드참여계수, 동적 증폭계수 등의 변화를 분석하였으며, 변위는 지진이력에 대한 약변, 강변, 무게중심 등에서의 변위를 비교하였다. 또한 이를 바탕으로 비틀림 응답을 최소화하기 위한 감쇠기의 적정 감쇠 편심 및 적정 감쇠 분배 문제에 대해 논하였으며, 단층구조물에서 유도된 적정 감쇠분배 방법을 다층구조뭍에 적용하고 그 효과를 확인하였다.

고층건물의 멀티 기둥그룹에 대한 부등기둥축소량의 최적보정기법 (Optimal Compensation of Differential Column Shortening in Tall Buildings for Multi Column Groups)

  • 김영민
    • 한국전산구조공학회논문집
    • /
    • 제21권2호
    • /
    • pp.189-197
    • /
    • 2008
  • 본 연구에서는 3개 이상의 기둥그룹에 대해서도 일반적으로 적용 가능한 기둥축소량의 최적보정기법을 제안하고, 이를 실제 시공된 건물에 적용하여 그 적용성을 평가하였다. 제안된 최적보정기법은 성능 및 시공상의 제약조건을 만족하면서 보정개소를 최소한으로 할 수 있는 층그룹 및 이때의 보정량을 산정하며, 상대보정뿐만 아니라 절대보정을 고려한 혼합보정도 가능하다. 최적보정에는 시뮬레이티드 어닐링(simulated annealing)이 주요 알고리즘으로 사용되었다. 제안된 기법을 실제 축소량 보정이 수행된 61층 건물에 적용한 결과, 보정량을 쉽게 산출할 수 있고 또한 실무방식보다 보정개소를 줄일 수 있어 적용성이 뛰어남을 확인하였다.

Seismic behavior of frames with innovative energy dissipation systems (FUSEIS 1-1)

  • Dougka, Georgia;Dimakogianni, Danai;Vayas, Ioannis
    • Earthquakes and Structures
    • /
    • 제6권5호
    • /
    • pp.561-580
    • /
    • 2014
  • After strong earthquakes conventional frames used worldwide in multi - story steel buildings (e.g. moment resisting frames) are not well positioned according to reparability. Two innovative systems for seismic resistant steel frames incorporated with dissipative fuses were developed within the European Research Program "FUSEIS" (Vayas et al. 2013). The first, FUSEIS1, resembles a vertical Vierendeel beam and is composed of two closely spaced strong columns rigidly connected to multiple beams. In the second system, FUSEIS2, a discontinuity is introduced in the composite beams of a moment resisting frame and the dissipative devices are steel plates connecting the two parts. The FUSEIS system is able to dissipate energy by means of inelastic deformations in the fuses and combines ductility and architectural transparency with stiffness. In case of strong earthquakes damage concentrates only in the fuses which behave as self-centering systems able to return the structure to its initial undeformed shape. Repair work after such an event is limited only to replacing the fuses. Experimental and numerical investigations were performed to study the response of the fuses system. Code relevant design rules for the seismic design of frames with dissipative FUSEIS and practical recommendations on the selection of the appropriate fuses as a function of the most important parameters and member verifications have been formulated and are included in a Design Guide. This article presents the design and performance of building frames with FUSEIS 1-1 based on models calibrated on the experimental results.

Damage assessment and performance-based seismic design of timber-steel hybrid shear wall systems

  • Li, Zheng;He, Minjuan;Li, Minghao;Lam, Frank
    • Earthquakes and Structures
    • /
    • 제7권1호
    • /
    • pp.101-117
    • /
    • 2014
  • This paper presents a reliability-based analysis on seismic performance of timber-steel hybrid shear wall systems. Such system is composed of steel moment resisting frame and infill wood frame shear wall. The performance criteria of the hybrid system with respect to different seismic hazard levels were determined through a damage assessment process, and the effectiveness of the infill wood shear walls on improving the seismic performance of the hybrid systems was evaluated. Performance curves were obtained by considering different target non-exceedance probabilities, and design charts were further established as a function of seismic weight. Wall drift responses and shear forces in wood-steel bolted connections were used as performance criteria in establishing the performance curves to illustrate the proposed design procedure. It was found that the presence of the infill wood shear walls significantly reduced the non-performance probabilities of the hybrid wall systems. This study provides performance-based seismic evaluations on the timber-steel hybrid shear walls in support of future applications of such hybrid systems in multi-story buildings.

Experimental studies on the behaviour of headed shear studs for composite beams in fire

  • Lim, Ohk Kun;Choi, Sengkwan;Kang, Sungwook;Kwon, Minjae;Choi, J. Yoon
    • Steel and Composite Structures
    • /
    • 제32권6호
    • /
    • pp.743-752
    • /
    • 2019
  • Steel and concrete composite structures are commonly applied in multi-story buildings as they maximise the material strength through composite action. Despite the popularity of employing a trapezoidal deck slab, limited experimental data are available under elevated temperatures. The behaviour of the headed shear stud embedded in a transverse trapezoidal deck and solid slab was investigated at both ambient and fire conditions. Twelve push-out tests were conducted according to the ISO 834 standard fire utilising a customised electric furnace. A stud shearing failure was observed in the solid slab specimen, whereas the failure mode was changed from a concrete-dominated failure to the stud shearing in the transverse deck specimen with an increase in temperature. Comparisons between the experimental observations and design requirements are presented. The Eurocode design guidance on the transverse deck slab gives a highly conservative estimate for shear resistance. A new design formula was proposed to determine the capacity of the shear connection regardless of the slab type when the stud shearing occurs at high temperatures.

1기 신도시 노후 공동주택 리모델링 평면 프로토타입 개발에 관한 연구 - 2 Bay 형식의 1기 신도시 대표유형을 중심으로 - (Development of Remodeling Prototype Plans in 1st-Phase New Town Aged Apartment - Based on '2 Bay Type' of 1st-Phase New Town Representatives -)

  • 최재필;최준호;김영선;문성훈
    • 대한건축학회논문집:계획계
    • /
    • 제34권6호
    • /
    • pp.67-76
    • /
    • 2018
  • A prototype of remodeling floor plans are proposed in this study. They are researched base on the majority floor plan type which forms 19% out of representatives 1st-Phase New Town Aged Apartment compositions. In order to examine possible scenarios of the prototypes, prototype planning model is derived from the president studies on aged apartment remodeling. The prototype plans reflect residents' preference survey and lead 6 different kinds of prototype plans regarding 3 different remodeling scenarios. Prototypes consider characteristics of multi-complex buildings and households which applicably various remodeling planning options; story-Increase remodeling, residents custom remodeling etc. The study has significance to be basic planning materials for remodeling of association and local government.

철골 끼움가새골조로 보강된 학교건물의 내진성능평가를 위한 비선형 해석 모델에 관한 연구 (Study on the Nonlinear Analysis Model for Seismic Performance Evaluation of School Buildings Retrofitted with Infilled Steel Frame with Brace)

  • 유석형;고관욱
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.65-72
    • /
    • 2022
  • 최근 국내 지진으로 인한 건축물의 피해는 주로 학교건물과 필로티형 다가구 주택에서 발생함으로써 동일한 형식의 건물에 대한 내진보강 필요성을 부각시켰다. 학교시설 내진보강사업은 초기에 연성보강방법으로서 댐퍼를 활용한 다양한 특허공법들이 충분한 검증 절차 없이 적용되었다. 그러나 「학교시설 내진성능평가 및 보강 매뉴얼, 2021」에서는 특허공법 적용시 별도의 엄격한 검증절차를 통하여 적용토록 하고 대신 일반공법으로서 강도/강성보강공법의 활성화를 유도하였다. 학교건물의 강도/강성 보강공법으로서 활발히 적용되고 있는 철골 끼움가새골조보강을 위한 내진선능평가 시 실무에서는 일부 제한된 조건에서 안전측의 내진성능평가 결과를 도출할 것으로 판단하여 기존 RC 부재에 철골가새만을 직접연결하여 해석모델을 구성하고 있다. 그러나 철골 끼움가새골조의 해석모델에서 프레임을 제거할 경우 강성감소로 인한 보강 부근의 기존 RC부재에 발생하는 하중감소는 매우 클 것으로 사료되며 이는 보강부위 기초보강 유무 검토에도 영향을 미칠 것으로 판단된다. 따라서 본 연구에서는 철골 끼움가새골조를 이용하여 저층 RC 학교건물 내진보강 시 성능평가를 위한 해석모델에 대하여 철골 프레임 고려 유무, 프레임 링크방식 등을 변수로 한 예비해석과 실제 3층 학교 건물에 대한 비선형 정적해석에 따른 내진성능평가 를 수행하였으며, 변수별 예비해석 및 푸쉬오버 해석결과를 비교함으로써 합리적인 해석모델 설정을 위한 기초자료를 제시하였다.

철골 모멘트 골조의 지진해석을 위한 등가 단자유도시스템 (Equivalent SDF Systems Representing Steel Moment Resisting Frames)

  • 한상환;문기훈;김진선
    • 한국지진공학회논문집
    • /
    • 제12권3호
    • /
    • pp.21-28
    • /
    • 2008
  • 다자유도 시스템의 내진 성능을 평가하기 위해서는 반복적인 비선형 시간 이력 해석이 필요하며 이를 위해 많은 계산과정과 노력이 필요하다. 이와 같이 해석에 따르는 어려움을 보완하기 위해 복잡한 다자유도 시스템을 반영할 수 있는 등가 단자유도 시스템을 개발하였다. 등가 단자유도의 이력 모델로는 일반적으로 이선형 모델과 삼선형 모델이 사용된다. 이러한 모델은 탄성 거동 이후 음강성을 가질 수 있도록 하여 지진 발생 시 중력하중에 의한 발생되는 효과를 반영하기 위해서이다. 본 연구에서는 철골모멘트 골조의 실제 응답을 예측하기 위하여 이러한 이력 모델들로 거동하는 등가단자유도 시스템의 필요조건에 대하여 평가하였다. 이를 위해 본 연구에서는 로스엔젤레스 지역의 SAC 9층 모멘트 저항 골조를 비선형 다자유도 시스템과 등가단자유도 시스템으로 모델링하여 반복하중 푸쉬오버 해석, 비선형 시간 이력해석 및 IDA(Incremental Dynamic Analysis)를 수행하여 비교 검토하였다. 또한 본 연구에서는 강도저감 모델에 대해서도 평가를 수행하였다.

도시생태계 현황파악 및 자연성 증진 방안 -서울시 강서구를 사례로- (Ecosystem Structure and Improvement of Naturalness in Urban Area -In the Case of Kangseo-gu in Seoul-)

  • 이수동;이경재
    • 한국조경학회지
    • /
    • 제32권3호
    • /
    • pp.1-17
    • /
    • 2004
  • The focus of this study is the promotion of green area volumes and their naturalness, water circulation system, decline of entropy, creation of biological habitats and linkage of separated urban green space. Re-presentative urban biotope survey sites were categorized as urban biotope, semi-natural biotope, and natural forest. In the urban biotope, a residential biotope was constructed near the Han river and in mountain areas. The green-area ratio at the housing complex was about 25%. GVZ(Grunvolumenzahl) was 0.35m$^3$/m$^2$ at the 5∼10-story housing complex, and 1.53m$^3$/m$^2$ over the 11-story. As for the green-area structure of the housing complex, canopy layer, understory layer, and shrub layer were not differentiated and the green-area volume was not high enough. The green-area ratio of school areas as a public area biotope was 5∼20%. GVZ was 1.12m$^3$/m$^2$ at Myungduk High School, and 1.78m$^3$/m$^2$ at Jeonggok Elementary School. In order to convert the urban biotope into an ecological area, green areas around the buildings should be connected to urban buffer green areas, and multi-layer structures should be established with natural plant species. In the semi-natural biotope, neighbor parks were created park in the vicinity of the natural forests. GVZ was 0.28m$^3$/m$^2$, and plantation was established with single layer structure and was definitely insufficient for the area. The urban buffer green areas have been established in strip corridors with the width of 20∼123m. In those areas, GVZ was 0.16∼0.27m$^3$/m$^2$ and had a deficient canopy layer, understory layer, and shrub layer. Soil conditions were not favorable for tree growth. In the natural biotope, GVZ of the plantation was 1.03∼1.5m$^3$/m$^2$ but the high crown closure of this area reduces the chance of species change and succession. GVZ of natural forest was 2.53∼2.57m$^3$/m$^2$. It is desirable to plant diverse plants and the natural forest should be succeeded by broad-leaf deciduous tree species. To improve the value of biotope at Kangseo-Gu, building height needs to be limited to reduce the environmental deterioration in the city. In order to maintain the water circulation system, water-permeable material is recommened when the urban surface areas are paved. The establishment of a water circulation system will improve ground water levels, soil moisture, water quality, and habitats. In order to improve biological diversity, it is desirable to have multi-layer structures in urban green areas with native species.