• Title/Summary/Keyword: multi-level signal

Search Result 249, Processing Time 0.035 seconds

Low frequency Multi-level Switching Strategy based on Phase-Shift Control (위상 변위제어기법을 이용한 저주파 다중레벨 스위칭 방식)

  • Song, Sung-Geun;Lee, Sang-Hun;Nam, Hae-Kon;Park, Sung-Jun;Lee, Man-Hyung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.6
    • /
    • pp.520-528
    • /
    • 2006
  • In this paper, we proposed the electric circuit using one common arm of H-Bridge Inverters to reduce the number of switching component in multi-level inverter combined with H-Bridge Inverters and Transformers. and furthermore we suggested the new multi-level PWM inverter using PWM level to reduce THD(Total Harmonic Distortion). and we used the phase-shift switching method that can be same rate of usage at each transformer. Also, we tested the proposed prototype 9-level inverter to clarify the proposed electric circuit and reasonableness of control signal for the proposed multi-level PWM inverter.

Sub-bottom Profiling Algorithm using Parametric Array (파라메트릭 배열을 이용한 해저지층 탐사 알고리즘)

  • Lee, Chong Hyun;Lee, Jaeil;Bae, Jinho
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.55-63
    • /
    • 2014
  • In this paper, we propose an threshold-based Schur algorithm for estimating the media characteristics of sub-bottom multi-layers by using the signal generated by a parametric array transducer. We use the KZK model to generate a parametric array signal, and use the proposed threshold-based Schur algorithm for estimating the reflection coefficients of multiple sea bottom layers. Using computer simulation, we verify that the difference frequency component generated by the KZK model prevails over the signals of primary frequencies at long range. For the simulation, we use the transmit signal generated by the KZK and the reflected signal obtained from a lattice filter model for the seawater and sub-bottom of multi-level non-homogeneous layers. Through the simulation, we verify that the proposed threshold-based Schur algorithm can give much more accurate and efficient estimates of the reflection coefficients than methods using received signal, matched filter output signal, and normal Schur algorithm output.

The Effects of Noise, Interference, and Carrier Offset on Multi-Level QPRS Signals (다치 직교 PRS 신호에 대한 잡음과 간섭 및 캐리어 옵셋의 영향)

  • Lee, Gwang-Ryel;Cho, Sung-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.869-873
    • /
    • 1987
  • In this study, we have examined the multi-level QPRS system in point of error rate, which requires narrow bandwidth and has Little ISI. The generalized error rate equations of multi-level QPRS signal have been derived in the presence of Gaussian noise and co-channel CW interference. And the error rate performance of 9, 49, 225 QPRS system is investigated as parameters of carrier power-to-noise power, carrier power-to -interference power. Also, we have investigated the effect of carrier offset.

  • PDF

A study on performance characteristic of Multi-level PDP driver circuit in accordance of signal time (Multi-Level을 사용한 PDP 구동회로에서 Timing 변화에 따른 특성 변화에 관한 연구)

  • Kim, J.S.;Kang, S.E.;Song, S.H.;Roh, J.W.;Hong, S.S.;SaKong, S.C.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.96-98
    • /
    • 2005
  • Proposed Multi-level PDP sustain Driver make use of element which has a low voltage rating instead of suggested method by the existing Webber and it passes through a second phase both rising and falling at sustaining voltage waveform In accordance with the change of timing phase(Tr1, Ti1, Tr2) performance comparison of a electric discharge characteristics in a PDP module has been carried out. At the conclusion of experimentation, the feature is extended by alteration of Ti1 and it has little to do with alteration of Tr1.

  • PDF

Multi-level Inverter Using 3-Phase isolated Transformers (3상 절연형 변압기를 이용한 다중레벨)

  • Lee, Hwa-Chun;Song, Sung-Gun;Park, Sung-Jun;Kim, Kwang-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1134-1135
    • /
    • 2007
  • In this paper, we proposed the isolated multi-level inverter using 3-phase transformers. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformer could be reduced comparing with an exiting 3-phase multi-level inverter using single phase transformer. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching losses can be reduced. Finally, we made a prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

  • PDF

Cooperative Interference Mitigation Using Fractional Frequency Reuse and Intercell Spatial Demultiplexing

  • Chang, Jae-Won;Heo, Jun;Sung, Won-Jin
    • Journal of Communications and Networks
    • /
    • v.10 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • For mobile wireless systems with full frequency reuse, co-channel interference near the cell coverage boundaries has a significant impact on the signal reception performance. This paper addresses an approach to efficiently mitigate the effect of downlink co-channel interference when multi-antenna terminals are used in cellular environments, by proposing a signal detection strategy combined with a system-level coordination for dynamic frequency reuse. We demonstrate the utilization of multi-antennas to perform spatial demultiplexing of both the desired signal and interfering signals from adjacent cells results in significant improvement of spectral efficiency compared to the maximal ratio combining (MRC) performance, especially when an appropriate frequency reuse based on the traffic loading condition is coordinated among cells. Both analytic expressions for the capacity and experimental results using the adaptive modulation and coding (AMC) are used to confirm the performance gain. The robustness of the proposed scheme against varying operational conditions such as the channel estimation error and shadowing effects are also verified by simulation results.

The Abnormal Condition Diagnosis of Compressor Parts using Multi-signal Sensing (복합신호 검출에 의한 압축기 부품의 상태 진단)

  • Lee, Kam-Gyu;Kim, Jeon-Ha;Kang, Ik-Su;Kang, Myung-Chang;Kim, Jeong-Suk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.3 no.3
    • /
    • pp.11-16
    • /
    • 2004
  • In this study, the characteristics of signals such as acoustic emission, vibration amplitude and noise level which are derived from the abnormal condition of compressor are investigated. The normal condition, vane stick sound and roller defect condition are chosen to analyze the signal in each cases. From the feature extraction of each signals, the dominant parameters of each signals which can identify the abnormal condition are suggested.

  • PDF

Combined Open Door Laminoplasty with Unilateral Screw Fixation for Unstable Multi-Level Cervical Stenosis : A Preliminary Report

  • Son, Seong;Lee, Sang Gu;Park, Chan Woo;Kim, Woo Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.2
    • /
    • pp.83-88
    • /
    • 2013
  • Objective : The authors reviewed their experiences of combined surgery (open door laminoplasty with unilateral screw fixation) for unstable multi-level cervical stenosis, to clarify the situation regarding the surgical approach most appropriate for the treatment of diffuse unstable multi-level cervical stenosis. Methods : From January 2011 to January 2012, combined surgery was performed for unstable multi-level cervical stenosis by one surgeon at our institution. The subjects of this study were 6 men of mean age 53.7 years (range, 48-71) with a mean follow-up of 9.3 (range, 3-14) months. All imaging studies showed severe multi-level cervical stenosis with spinal cord signal change, and instability or kyphotic deformity. A retrospective review of clinical, radiological, and surgical data was conducted. Results : Average laminoplasty level was 4.8 and the average screw fixation level was 5.0. Japanese Orthopedic Association score improved from an average of 5.2 to 11.2 points. According to Nurick's grades and Odom's criteria, symptom improvement was statistically significant. On the other hand, Cobb's angle changes were not significant. Average operation time was 5.86 hours with an average blood loss of 460 mL. No significant surgical complication was encountered. Conclusion : Despite the small cohort and the short follow-up duration, the present study demonstrates that laminoplasty with unilateral screw fixation is a safe and effective treatment for unstable multi-level cervical stenosis.

Single Phase 5-level Inverter with DC-link Switches (DC링크 스위치를 갖는 단상 5레벨 인버터)

  • Choi, Young-Tae;Sun, Ho-Dong;Park, Min-Young;Kim, Heung-Geun;Chun, Tea-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.283-292
    • /
    • 2011
  • This paper proposed a new multi-level inverter topology based on a H-bridge with two switches and two diodes connected to the DC-link. The output voltage of the proposed topology is quite closer to a sinusoidal waveform compared with a typical single phase inverter. The proposed multi-level inverter is applicable to a power conditioning system for renewable energy sources, and it can be also used as a building block of a cascaded multi-level inverter for a high voltage application. In case of conventional H-bridge type or NPC type multi-level inverter, 8 controllable switches are used to obtain a 5 level output voltage, but the proposed multi-level inverter requires only 6 controllable switches. Thus the circuit configuration is quite simple, reliable and cost-effective implementation is possible. The efficiency can be improved owing to the reduction of the switching loss. A new PWM method based on POD modulation is suggested which requires only one carrier signal. The switching sequence to make the capacitor voltage balanced is also considered. The feasibility is studied through simulation and experiment.

Sea Level Valiability and Eddy in the South Indian Ocean by Multi-satellite Data (Topex/Poseidon, ERS1) (복합위성자료(Topex/Poseidon, ERS1)를 이용한 남인도양의 해수면 변화와 와동류 연구)

  • 윤홍주;서영상
    • Korean Journal of Remote Sensing
    • /
    • v.19 no.4
    • /
    • pp.271-276
    • /
    • 2003
  • Sea level variability and eddy in the Amsterdam-Crozet-Kerguelen region of the South Indian Ocean were studied during 1 year (October 15, 1992~October 15, 1993) using multi-satellite data (Topex/Poseidon, ERS1) produced by signal treatment. We found that sea level variabilities (>10cm) generally exist along the Antarctic Circumpolar Current in the area of 35$^{\circ}$~46$^{\circ}$S and strong sea level variabilities (20~30cm) were especially occurred from the effects of eddy due to bottom topography in two small area: 49$^{\circ}$~57$^{\circ}$E and 38$^{\circ}$~42$^{\circ}$S, and 58$^{\circ}$~64$^{\circ}$E and 42$^{\circ}$~44$^{\circ}$S.