• Title/Summary/Keyword: multi-level rotation design

Search Result 14, Processing Time 0.026 seconds

Development of a Mathematical Model for Effect of Scoliosis Surgical Correction (구조해석을 통한 척추측만증 교정 분석에 필요한 모델 개발)

  • 김영은;최형연;손창규;이광희;이춘기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1059-1061
    • /
    • 2002
  • A FE model is to develop a personalized biomechanical model of the scoliotic spine that will allow the design of clinical test providing optimal estimation of the post-operation results. A flexible multi-body model of the spine including rib cage, clavicle, and scapular was developed to simulate several mobility simulations. Vertebrae, clavicle and scapular were represented using rigid bodies and ribs and sternum were modeled as flexible bodies. Kinematical Joints and spring elements were used to represent the intervertebral disc and ligaments respectively. Postero-anterior and lateral radiographics of a scoliotic spine were used to represent a 3D reconstruction. CT data for same patient were also used to verify vertebrae rotation driven from postero-anterior and lateral radiographic images. Simulated results showed good reducibility almost uniformly distributed along the spinal segments. It was also found that boundary and loading conditions, required to mimic the operation procedures, were proven to be very sensitive parameters to its results rather than its mechanical properties

  • PDF

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Causes of Cyber Sickness of VR Contents: An Experimental Study on the Viewpoint and Movement (VR 콘텐츠의 사이버 멀미 유발 요인: 시점과 움직임의 효과에 대한 실험 연구)

  • Jung, Ji-Young;Cho, Kwang-Su;Choi, Jinhae;Choi, Junho
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.4
    • /
    • pp.200-208
    • /
    • 2017
  • Despite a rapid market growth in VR, cyber sickness has become the most serious problem in terms of user experience. The aim of this study is to verify whether there are differences in user's perception of cyber sickness by the point-of-view and the movement in VR contents. An experimental testing of game playing with VR headset was conducted on the effects of two conditions: first-person and third-person views in the point-of-view condition, and yaw - pitch rotations in the head movement condition. The results showed that cyber sickness worsened in the first-person point-of-view and in the yaw rotation movement. Point-of-view and movement had main effects on the cyber sickness, but an interaction effect between point-of-view and movement was not found. Based on the findings, along with reducing VR sickness, we proposed practical implications for VR contents planning for building balanced VR user experience. Positive VR experience can be reinforced through visual design, multi-modal interface design, and experience marketing for the optimal level of contents immersion. A future research was suggested on the roll rotation for diverse content genre development.

The Experiment for Performance Evaluation of Column-rafter-purlin Connections of an Arch-type Plastic Multi-span Greenhouse (플라스틱 연동온실 기둥-서까래-도리 접합부의 성능 평가 실험)

  • Choi, Man-kwon;Ryu, Hee-ryong;Cho, Myeong-whan;Yu, In-ho;Kim, Seung-yu
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.473-479
    • /
    • 2020
  • In this study, the structural experiment was conducted with two types of specimens to investigate the mechanical behavior of the column-rafter-purlin connection of an arch-type greenhouse under monotonic loading. Based on the experimental results, the flexural performance was analyzed for two types of connections, and connection classification was attempted. Type B showed 77% of flexural performance compared to Type A, and both types showed that the rigidity and flexural strength did not reach the level of the full rigid. The behavior of the column-rafter-purlin connection was dominated by local buckling due to deformation of the weld and fasteners. As a result of connection classification by AISC standard, both Type A and B connections showed a result that did not meet the rigid connection performance assumed during design, and were classified as simple connection. Therefore, the connection performance evaluation and classification results show that the greenhouse design should be made in consideration of connection performance and in order to design a reliable greenhouse structure, a study on establishing clear design standards for the greenhouse connection is necessary.