• Title/Summary/Keyword: multi-lamp

Search Result 85, Processing Time 0.026 seconds

Variable Pulse Generation Technology of Pusle ND:YAG Laser Using Real Time Multi-Discharge

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.102.2-102
    • /
    • 2001
  • In this study, a solid-state laser system adopting a new real time multi-discharge (RTMD) method in which three flashlamps are turned on consecutively was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. That is, this study shows a technology that makes it possible to make various pulse shapes by turning on three flashlamps consecutively on a real-time basis with the aid of a PIC one-chip microprocessor, With this technique, the lamp turn-on delay time can be varied more diversely from 0 to 10 ms and the real-time control is possible with an external keyboard, enabling various pulse shapes. In addition, longer pulses can be more widely used for industrial processing and lots of medical purposes.

  • PDF

Design of Inverter for driving the Multi-lamp using a Piezoelectric Transformer (압전 변압기를 이용한 멀티램프 구동용 인버터 설계)

  • Cho Sung Koo;Lim Young Cheol;Yang Seung Hak
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.465-469
    • /
    • 2004
  • 액정 디스플레이의 백라이트 광원으로 냉음극 방전램프(CCFL: Cold Cathode Fluorescent Lamp)가 일반적으로 사용된다 최근 LCD 모니터의 두께는 갈수록 얇아지며, 화면은 넓어지고 있는 대형화 추세이다. 기존의 권선형 변압기를 이용 인버터를 구성하여 멀티램프를 구동하고 있지만 이는 코어나 권선 손실에 의한 효율 저하와 부피나 중량의 증가, 그리고 과열에 의한 화재의 위험성을 가지고 있다. 이러한 문제들을 해결하기 위해 본 논문에서는 압전 변압기를 이용한 멀티램프 구동용 인버터를 설계 지침에 따라 구성하였다. 인버터 하나로 압전변압기를 병렬로 연결하는 방식을 이용하였고, 또한 전류 부담이 적은 외관 전극 형광 램프(EEFL: External Electrode Fluorescent Lamp)를 이용한 멀티램프 구동 방법을 압전 인버터에 적용 가능한지 고찰하였다. 적용한 방식으로는 풀-브리지 (Full-Bridge)회로를 응용하였다.

  • PDF

Scanning of Mercury-free Flat Fluorescent Lamp(MFFL) for LCD Backlight

  • Seo, In-Woo;Jung, Jae-Chul;Oh, Byung-Joo;Kim, Hyuk;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.827-830
    • /
    • 2008
  • We proposed a new Mercury-free flat fluorescent lamp (MFFL) for LCD backlight which has the scanning ability to reduce the blurring edges of moving images. We expanded the single cell MFFL with 2.2 inch diagonal size into the multi-cell MFFL for the 32-inch LCD-TV backlight application, and examined its response characteristics and proposed a driving scheme for scanning.

  • PDF

Driving Method of Direct Type Multi-Lamp Backlight with High Uniformity (고균일도 직하형 백라이트 구동방법)

  • Chun, Young-Tea;Lim, Sung-Kyoo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.123-127
    • /
    • 2004
  • Cold cathode fluorescent lamp (CCFL) has been used as a light source for direct type backlights for LCD monitors or TV. One inverter for one CCFL was necessary for maintaining the lamp current so that many inverters were used to drive as many CCFLs of direct type backlight for LCD TV. An inverter for driving 16 CCFLs was developed to reduce the backlight cost. The length and diameter of CCFL were 450mm and 4mm, respectively. Backlight including 16 CCFLs for 26" LCD TV was assembled by using one inverter. The uniformities of the assembled backlight operated by the conventional inverter and the newly developed inverter were 75% and 88%, respectively.

  • PDF

High Luminous Efficiency Flat Light Source with Xe mixture Gas Discharge and Areal Brightness Control Method (제논 혼합가스를 이용한 고효율 면광원과 국부적 밝기 제어 방식)

  • Jung, Jae-Chul;Seo, In-Woo;Oh, Byung-Joo;Whang, Ki-Woong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.153-157
    • /
    • 2009
  • A Highly efficient Mercury-free Flat Fluorescent Lamp (MFFL) with dielectric barrier Xe gas discharge was developed for an alternative of conventional line-type Cold Cathode Fluorescent Lamps (CCFLs) which shows a wide voltage margin and a stable discharge operation for diffuse glow discharge with an application of a auxiliary electrode. Electro-optic characteristics of the MFFL were examined through the changes in ambient temperature, total pressure and Xe partial pressure. the single cell is expanded into a multi-structured configuration to realize a large sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive brightness control using dual auxiliary electrodes and bi-polar drive scheme. In addition, interesting application of this ultra high luminance flat lamp by the optimization of the gas condition and the pattern of the rear phosphor layer is suggested as a good alternative of daylight lamp source

  • PDF

Frequency Synchronization for LCD TV Backlight

  • Kim, Young-Se;Lee, Kwang-Kyu;Lim, S
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1149-1152
    • /
    • 2005
  • The frequency of inverters for driving multi-lamp backlights for LCD TV was synchronized to reduce noise from lamps and noise generated from PWM dimming.

  • PDF

Development of Excitation Light Source for Photodynamic Diagnosis of Cancer (광역학적 암진단을 위한 여기 광원장치의 개발)

  • Lim, Hyun-Soo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.49-56
    • /
    • 2007
  • In this paper, the development of excitation light source is proposed for excitation light of the photodynamic therapy of cancer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosensitizer. This study aims at designing and evaluating light source that can stably generate light with various kinds of wavelengths in order to make possible photodynamic diagnosis using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source device by KFDA#s technical reference, the characteristics of the light output and wavelength band were found.

Development portable hair removal applies PET ($Pause^{10-90}$ and $Energy^{20-40}$ $Trigger^{1-7}$) function

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.223-230
    • /
    • 2009
  • For pulse trigger way and the energy injection rate according to PET ($Pause^{10-90}$ $Energy^{20-40}$ $Trigger^{1-7}$) function, indeed, human body condition, period of dormancy in this research about this back correctly adjustment possible and designed harmless micro carrying along style hair exclusion so that can design and manufacture and run special quality examination and Xenon flash lamp to crawl in human body. Because creating individual's skin model to do stable treatment by light transmission way by skin impedance and measure, must embody treatment special quality of most suitable that draw skin color, energy, wave length, approximately, transmission time, pulse delay etc. and want. Specially, saved standard of war treatment pulse modeling by skin impedance, and manufacture pulse modeling system of most suitable by skin subordinate, and embody suitable treatment pulse. Specially, embody as could do root of a hair exclusion being emitted in pulse form using multi wave length of 560nm, 590nm, 640nm, 755nm and embodied clinical data. If become research repletion furthermore little more, is seen that can approximate in commercialization.

Long Pulse Generation Technology of an Alexandrite Laser System for Hair Removal

  • Kim, Hee-Je;Park, Jin-Young;Kwak, Su-Young;Kim, Su-Weon;Min, Byoung-Dae;Jung, Jong-Han;Hong, Jung-Hwan
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.155-160
    • /
    • 2003
  • In this study, an Alexandrite laser system for hair removal adopting a multi-discharge method in which three flash lamps are turned on consecutively was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. Specifically, this study demonstrates a technology that makes it possible to formulate various pulse shapes by turning on three flashlamps consecutively on a real-time basis with the aid of a PIC (program integrated circuit) one-chip microprocessor. With this technique, the lamp turn-on delay time can be varied more diversely from 0 to 10 ms and real-time control is possible with an external keyboard, enabling an assortment of pulse shapes. In addition, longer pulses can be more widely used for industrial processing as well as for numerous medical purposes.

A Study on Luminescence and Discharge Characteristics of EEFL (External Electrode Fluorescent Lamp) Driven by Square Wave for Large sized-LCD panel (대형 액정디스플레이패널의 백라이트용 외부 전극 형광램프의 구형파 구동 방법에 대한 휘도, 방전 특성 연구)

  • Cho Dae-Youn;Lee Yeon-Jae;Cho Kyu-Min;Oh Won-Sik;Moon Gun-Woo;Lee Sang-Gil;Park Mun-Soo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.409-412
    • /
    • 2006
  • EEFL can be driven by square wave driving method. A square wave is applied directly to both ends of EEFL by cascaded multi-stage full-bridge inverter. The various current shapes of lamp are achieved by various inductors between lamp and inverter. In this paper, it is newly investigated that the area of current directly influences the luminance. Furthermore, the 3-level square wave is considered to drive EEFL with self-discharge characteristics. The highest luminance efficiency is achieved by properly controlling the rate of self-discharge usage.

  • PDF