• Title/Summary/Keyword: multi-force balance system

Search Result 13, Processing Time 0.025 seconds

Wind-induced response of a twin-tower structure

  • Xie, Jiming;Irwin, Peter A.
    • Wind and Structures
    • /
    • v.4 no.6
    • /
    • pp.495-504
    • /
    • 2001
  • With a newly developed multi-force-balance system(MFB), a twin-tower structure was studied for its wind-induced responses. The MFB system allowed the twin towers, which were linked structurally, to be treated as a single structural system with its corresponding modes of vibration involving coupled motions of the two towers. The towers were also studied using a more conventional force balance approach in which each tower was treated as an isolated structure, i.e., as though no structural link existed. Comparison of the results reveals how the wind loads between the towers are redistributed through the structural links and the modal couplings. The results suggest that although the structural links usually have beneficial impacts on wind-induced response, they may also play a negative role if the frequency ratios of pair modes are near 1.0.

HFFB technique and its validation studies

  • Xie, Jiming;Garber, Jason
    • Wind and Structures
    • /
    • v.18 no.4
    • /
    • pp.375-389
    • /
    • 2014
  • The high-frequency force-balance (HFFB) technique and its subsequent improvements are reviewed in this paper, including a discussion about nonlinear mode shape corrections, multi-force balance measurements, and using HFFB model to identify aeroelastic parameters. To apply the HFFB technique in engineering practice, various validation studies have been conducted. This paper presents the results from an analytical validation study for a simple building with nonlinear mode shapes, three experimental validation studies for more complicated buildings, and a field measurement comparison for a super-tall building in Hong Kong. The results of these validations confirm that the improved HFFB technique is generally adequate for engineering applications. Some technical limitations of HFFB are also discussed in this paper, especially for higher-order mode response that could be considerable for super tall buildings.

Speed and Tension Control of Continuous Strip Processing Line using Continuous Load Balance Control (연속 부하 분담 제어를 이용한 연속 구동 시스템의 속도 및 장력 제어 특성 개선)

  • Song, Seung-Ho;Seol, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.9
    • /
    • pp.503-509
    • /
    • 1999
  • This paper proposes a new speed and tension control algorithm for multi-span continuous strip processing line. In this algorithm the speed reference of each roll is adjusted to make the output force follow the load balance reference using an outer loop controller in cascade. Using the information of the output force of the adjacent roll, it is shown that the strip tension between two rolls can be controlled as the desired value without tension sensor. An experimental set-up which consists of 4 driven and 3 measuring rolls is designed and built for the multi-span speed and tension control. The experimental result reveals conspicuous improvement of tension control performance by the proposed algorithm comparing to the conventional tension feedback controller.

  • PDF

Vibration Characteristics of High Pressure Multi-Stage Pump with Anti-Swirl Injection Balance Sleeve (역스월 유로 입력을 가지는 밸런스 슬리브를 적용한 고압 다단 펌프의 진동 특성)

  • 곽현덕;이용복;김창호;이봉주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.214-219
    • /
    • 2002
  • As the tangential flow inside the clearance of tribe elements such as bearings and seals is increased as the shaft speed increases, the system stability will be decreased due to the increment of the instability parameter. To reduce the tangential flow inside the clearance of the balance sleeve, anti-swirl injection mechanism is applied. The balance sleeve is used in resisting the axial force induced by impeller in high pressure multi-stage pump. In this paper, total three cases are experimentally investigated; original balance steeve, anti-swirl injection balance steeve with 0 axial degree and anti-swirl injection balance sleeve with 30 axial degree. Experiments are focused in the comparison of vibration level and leakage flow rate. The results clearly shows that the anti-swirl injection balance sleeve with 0 axial degree improves the vibration characteristics. However, the anti-swirl injection balance sleeve with 30 degree aggravates the vibration characteristics. In the standpoint of leakage performance, both anti-swirl injection balance sleeves show the better result than the original balance sleeve.

  • PDF

Vibration Characteristics of High Pressure Multi-stage Pump with Anti-swirl Injection Balance Sleeve (역스월 유로 입력을 가지는 밸런스 슬리브를 적용한 고압 다단 펌프의 진동 특성)

  • 곽현덕;이용복;김창호;이봉주
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.8
    • /
    • pp.632-638
    • /
    • 2002
  • As the tangential flow inside the clearance of tribo elements such as bearings and seals is increased as the shaft speed increases, the system stability will be decreased due to the increment of the instability parameter. To reduce the tangential flow inside the clearance of the balance sleeve, anti-swirl injection mechanism is applied. The balance sleeve is used in resisting the axial force induced by impeller in high pressure multi-stage pump. In this paper, total three cases are experimentally investigated; original balance sleeve, anti-swirl injection balance sleeve with 0 axial degree and anti-swirl injection balance sleeve with 30 axial degree. Experiments are focused in the comparison of vibration level and leakage flow rate. The results clearly shows that the anti-swirl injection balance sleeve with 0 axial degree improves the vibration characteristics. However, the anti-swirl injection balance sleeve with 30 degree aggravates the vibration characteristics. In the standpoint of leakage performance, both anti-swirl injection balance sleeves show the better result than the original balance sleeve.

A New Training System for Improving Postural Balance Using a Tilting Bed

  • Yu, Chang-Ho;Kwon, Tae-Kyu;Ryu, Mun-Ho;Kim, Nam-Gyun
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.117-126
    • /
    • 2007
  • In this paper, we propose an early rehabilitation training system for the improvement of postural balance with multi-modality on a tilting bed. The integration of the visual, somatosensory and vestibular functions is significant to for maintaining the postural control of the human body. However, conventional rehabilitation systems do not provide multi-modality to trainees. We analyzed the characterization of postural control at different tilt angles of an early rehabilitation training system, which consists of a tilting bed, a visual feedback, a computer interface, a computer, and a force plate. The software that we developed for the system consists of the training programs and the analysis programs. To evaluate the characterization of postural control, we conducted the first evaluation before the beginning of the training. In the following four weeks, 12 healthy young and 5 healthy elderly subjects were trained to improve postural control using the training programs with the tilting bed. After four weeks of training, we conducted the second evaluation. The analysis programs assess (center of pressure) COP moving time, COP maintaining time, and mean absolute deviation of the trace before and after training at different tilt angles on the bed. After 4 weeks, the COP moving time was reduced, the COP maintaining time was lengthened, and the mean absolute deviation of the trace was lowered through the repeated use of vertical, horizontal, dynamic circle movement training programs. These results show that this system improves postural balance and could be applied to clinical use as an effective training system.

Effect of Friction on the Hysteresis of the Thrust Forces Acting on Auto Leveling Devices in Vehicle Head Lamps (헤드 램프 빛의 각도 자동 조절 장치에 작용하는 추력의 히스테리시스에 대한 마찰의 영향)

  • Baek, Hong;Kim, Jae-Hoon;Nam, Jin-Sik;Park, Sang-Shin
    • Tribology and Lubricants
    • /
    • v.35 no.6
    • /
    • pp.369-375
    • /
    • 2019
  • This paper presents a new method on how to calculate the thrust forces acting on an auto-leveling device in headlamps for passenger vehicles. The leveling device is used to lower the angle of lights when a load in the trunk of the vehicle lifts it. In the process of the headlamp design, it is imperative to predict the external forces so that the designers can decide whether to proceed or not. The device is composed of three pivot joints with no reaction moment, a plate that holds the lamp, and a leveling motor that changes rotation to linear motion. In this study, force balance, moment balance, and geometric compatibility are applied to the leveling device system so that a nonlinear system of equations can be derived; the multi-dimensional Newton-Raphson algorithm is then used to solve these. A sensitivity analysis is carried out to verify which design variables affect the system the most: the mass of the lamp and the height between the pivot and leveling device affect the thrust forces the most. Then, considering the friction forces between the moving parts, the hysteresis of the forces are derived. An experimental apparatus, designed and developed in this study, is used to verify the exactness of the derived equations. The results from experiments coincide well with the calculated results. The friction hysteresis, in particular, proves this upon analysis.

The Structure of Oriental Wooden Pagoda (동양목조탑파(東洋木造塔婆)의 구조형식(構造形式)에 관한 연구(硏究) - 법주사(法住寺) 팔상전(捌相殿)과 법륭사(法隆寺) 오중탑(五重塔)의 비교분석적 측면에서 -)

  • Kim, Kyeong-Pyo;Fujii, Keisuke;Lee, Min-Sup
    • Journal of architectural history
    • /
    • v.1 no.1 s.1
    • /
    • pp.88-105
    • /
    • 1992
  • This dissertation aims to investigate the structure of Palsangjeon, a five story wooden pagoda in Pubjoo Temple which is the only wooden pagoda existing in Korea, by a comparative study of the Palsangjeon with Japanese counterparts. By doing so, the writer of the present investigation attempts to find out its structural originality. The main finding of this study are as follows. The upper part of Palsangjeon is constructed with square log frameworks called GuiTl and Sacheon-Ju around the central column. The four walls along Sacheon-Ju from the 1st level to the 3rd well resists the outside horizontal piressure. And Gui-Tl structure on the 5th level copes much better with shear force. So this frame consisting of Sacheon-Ju and log frameworks might be viewed an semi-core system, This core is supported once again by the frame of Go-Ju. That is to say. Go-Ju supports frame of Sacheon-Ju. And the frame of Pyeong-Ju on the 4th and the 5th levels also supports it. The frame of Go-Ju is supported by the frame of Pyeong-Ju on the 1st and the 2nd levels. So this structure is designed to resist the wind and also keep the balance by properly distributing vertical pressure. The plan and the elevational structure of Palsangjeon keep the balance by the perfect symmetric structure. And the frame of Sacheon-Ju forming semi-core system can resist both the lateral load and the vertical pressure for the balance of its structure. The five story pagoda in Horyuji used to stand on a central which is desigend to support the main body of the pagoda from the first level. The principles of balance is used between the Ha-Aag and short to react the rafter. Sacheon-Ju and edge column is against the lateral load. The structural jointing system is stable thanks to the log framewroks formed on every level. The five story pagoda in Horyuji poseses the structual system originated from the ancient wooden pagoda. The pagoda is found to express simple, sincere and straight forward form. On the other hand, it could be seen as a stucture resisting the earthquake and the lateral load, Palsangjeon is an excellent building which religions function is well harmonized with its structure and appearance. It not only functions extremely well as a regions place like other pagodas, but also excellently shows how multi-story wooden building should be structured.

  • PDF

South Korea's strategy to cope with local provocations by nuclear armed North Korea (핵위협하 국지도발 대비 대응전략 발전방향)

  • Kim, Tae-Woo
    • Strategy21
    • /
    • s.31
    • /
    • pp.57-84
    • /
    • 2013
  • North Korea's continuous threats and provocative behaviors have aggravated tension on the Korean peninsula particularly with the recent nuclear weapons test. South Korea's best way to cope with this situation is to maintain the balance among three policy directions: dialogue, sanctions, and deterrence. Among the three, I argue that deterrence should be prioritized. There are different sources of deterrence such as military power, economic power, and diplomatic clouts. States can build deterrence capability independently. Alternatively, they may do so through relations with other states including alliances, bilateral relations, or multilateral relations in the international community. What South Korea needs most urgently is to maintain deterrence against North Korea's local provocations through the enhancement of independent military capability particularly by addressing the asymmetric vulnerability between militaries of the South and the North. Most of all, the South Korean government should recognize the seriousness of the negative consequences that North Korea's 'Nuclear shadow strategy' would bring about for the inter-Korea relations and security situations in Northeast Asia. Based on this understanding, it should develop an 'assertive deterrence strategy' that emphasizes 'multi-purpose, multi-stage, and tailored deterrence whose main idea lies in punitive retaliation.' This deterrence strategy requires a flexible targeting policy and a variety of retaliatory measures capable of taking out all targets in North Korea. At the same time, the force structures of the army, the air force, and the navy should be improved in a way that maximizes their deterrence capability. For example, the army should work on expanding the guided missile command and the special forces command and reforming the reserve forces. The navy and the air force should increase striking capabilities including air-to-ground, ship-to-ground, and submarine-to-ground strikes to a great extent. The marine corps can enhance its deterrence capability by changing the force structure from the stationary defense-oriented one that would have to suffer some degree of troop attrition at the early stage of hostilities to the one that focuses on 'counteroffensive landing operations.' The government should continue efforts for defense reform in order to obtain these capabilities while building the 'Korean-style triad system' that consists of advanced air, ground, and surface/ subsurface weapon systems. Besides these measures, South Korea should start to acquire a minimum level of nuclear potential within the legal boundary that the international law defines. For this, South Korea should withdraw from the Nuclear Non-proliferation Treaty. Moreover, it should obtain the right to process and enrich uranium through changing the U.S.-South Korea nuclear cooperation treaty. Whether or not we should be armed with nuclear weapons should not be understood in terms of "all or nothing." We should consider an 'in-between' option as the Japanese case proves. With regard to the wartime OPCON transition, we need to re-consider the timing of the transition as an effort to demonstrate the costliness of North Korea's provocative behaviors. If impossible, South Korea should take measures to make the Strategic Alliance 2015 serve as a persisting deterrence system against North Korea. As the last point, all the following governments of South Korea should keep in mind that continuing reconciliatory efforts should always be pursued along with other security policies toward North Korea.

  • PDF

Application of tuned liquid dampers in controlling the torsional vibration of high rise buildings

  • Ross, Andrew S.;El Damatty, Ashraf A.;El Ansary, Ayman M.
    • Wind and Structures
    • /
    • v.21 no.5
    • /
    • pp.537-564
    • /
    • 2015
  • Excessive motions in buildings cause occupants to become uncomfortable and nervous. This is particularly detrimental to the tenants and ultimately the owner of the building, with respect to financial considerations. Serviceability issues, such as excessive accelerations and inter-story drifts, are more prevalent today due to advancements in the structural systems, strength of materials, and design practices. These factors allow buildings to be taller, lighter, and more flexible, thereby exacerbating the impact of dynamic responses. There is a growing need for innovative and effective techniques to reduce the serviceability responses of these tall buildings. The current study considers a case study of a real building to show the effectiveness and robustness of the TLD in reducing the coupled lateral-torsional motion of this high-rise building under wind loading. Three unique multi-modal TLD systems are designed specifically to mitigate the torsional response of the building. A procedure is developed to analyze a structure-TLD system using High Frequency Force Balance (HFFB) test data from the Boundary Layer Wind Tunnel Laboratory (BLWTL) at the University of Western Ontario. The effectiveness of the unique TLD systems is investigated. In addition, a parametric study is conducted to determine the robustness of the systems in reducing the serviceability responses. Three practical parameters are varied to investigate the robustness of the TLD system: the height of water inside the tanks, the amplitude modification factor, and the structural modal frequencies.