• 제목/요약/키워드: multi-discharge

검색결과 363건 처리시간 0.034초

희박연소용 점화장치에 대한 기초연구 (A basic study on ignitor for lean burn)

  • 이상준;나성오;이종태
    • 대한기계학회논문집B
    • /
    • 제21권1호
    • /
    • pp.36-48
    • /
    • 1997
  • In order to establish the ignition system for lean burn, the influence of the number of spark plug, spark times and spark intervals on discharge pattern of spark energy on ignitability and combustion characteristics were evaluated. It showed that, ignitability remarkably increased with the case of multiple spark ignition system than with the case of single spark and the lean limit extended fuel/air equivalence ratio by 0.1, the increase of magnitude and lasting time of capacity component and inductance component was multi spark discharge in a row.

다수 변압기의 온라인 모니터링을 위한 실제 적용 (Practical Applications of Multi-Agent Transformer Condition Monitoring)

  • 윤주호;최용성;황종선;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.96-99
    • /
    • 2008
  • On-line condition monitoring is a useful tool for maintaining and extending the longevity of power transformers. An intelligent diagnostic system is desirable for operational safety and reliability. Bringing these concepts together results in a powerful support tool for engineers, reducing the volume of data to deal with, and making the data more meaningful. This paper describes how a multi-agent system for diagnosing the cause of transformer partial discharge activity was coupled with a method of UHF partial discharge monitoring, creating an on-line condition monitoring system. The challenges presented by the on-site environment are discussed, along with the implications for the complete system.

  • PDF

Variable Pulse Generation Technology of Pusle ND:YAG Laser Using Real Time Multi-Discharge

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.102.2-102
    • /
    • 2001
  • In this study, a solid-state laser system adopting a new real time multi-discharge (RTMD) method in which three flashlamps are turned on consecutively was designed and fabricated to examine the pulse width and the pulse shape of the laser beams depending upon the changes in the lamp turn-on time. That is, this study shows a technology that makes it possible to make various pulse shapes by turning on three flashlamps consecutively on a real-time basis with the aid of a PIC one-chip microprocessor, With this technique, the lamp turn-on delay time can be varied more diversely from 0 to 10 ms and the real-time control is possible with an external keyboard, enabling various pulse shapes. In addition, longer pulses can be more widely used for industrial processing and lots of medical purposes.

  • PDF

Application of RBFN Using LPC of PD Pulse Shapes for Discriminating Among Multi PD Sources

  • Lee, Kang-Won;Lim, Kee-Joe;Kang, Seong-Hwa
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제3C권5호
    • /
    • pp.177-181
    • /
    • 2003
  • Partial discharge pulse shapes from variable PD (partial discharge) sources sustain many characteristics such as types of PD. Ultra high frequency antennas have wide bandwidth from 30KHz to 2㎓. Therefore, signals taken from a UHF antenna have important attributes (rising time, falling time, shape factor, etc.) for electromagnetic sources, such as PD sources. We investigated PD pulse shapes from several PD sources using a UHF antenna and the results were used for classification of PD sources. Features for discrimination are extracted from frequency distribution and LPC (Linear Prediction Coefficient) of time signal. RBFN are used for investigating the possibility of classification of multi-PD sources.

펄스전압을 안가한 엔톱날형 오존 발생기의 특성연구 (Parametric Study of a Sawtooth Disk Type Ozonizer Applying a Pulse Voltage.)

  • 문재덕;김창수
    • 대한전기학회논문지
    • /
    • 제36권11호
    • /
    • pp.806-812
    • /
    • 1987
  • The ozone generation characteristics are reported for a sawtooth disk to cylinger geometry using positive and negative pulse corona. A series of parametric studies was carried out to obtain optimum values for the pulse repetition frequency as well as the shape and dimensions of the discharge disk and the discharge spacing. Two types of ozonizers were studied: the single disk and the multi-disk. The results of the single disk ozonizer showed that positive corona produced a singificantly higher ozone yield than negative(7ppm/peak watt or 3.5 times larger). However the negative corona produced a much more controllable output which enabled the ozone generation to be directly controlled by adjusting the value of the peak pulse voltage. This results showed that the single disk ozonizer is ideally suited for applications requiring very small controlled quantities of ozone whereas the multi-disk unit can be designed to provide varying outputs depending upon the number of disk electrodes used.

  • PDF

다수 스위칭 제어를 통한 Multi-Discharge방식의 고체레이저 출력파형 연구 (A study of the output waveform of solid-state laser of multi-discharge method by various switching control)

  • 곽수영;김상길;홍정환;노기경;강욱;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1852-1854
    • /
    • 2003
  • In manufacturing processes, various and suitable pulse shapes are required for the purpose of material processing. In order to make various pulse shapes with variable pulse length and high duty cycle, We have fabricated the power supply consisting 6 SCRs and the Pulse Forming Network(PFN) with the precise delay time control. So our control system has three switching circuits, 3 mesh PFN, and simmer circuit. In addition, we have designed and fabricated the PIC one-chip microprocessor(16F877) to control the delay time of sequential switching.

  • PDF

변압기 상태의 온라인 감시 체계 구축에 대한 연구 동향 (A Research Trend on Multi-Agent Transformer Condition Monitoring System On-Line)

  • 김정훈;용형식;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2006-2007
    • /
    • 2007
  • On-line condition monitoring is a useful tool for maintaining and extending the longevity of power transformers. An intelligent diagnostic system is desirable for operational safety and reliability. Bringing these concepts together results in a powerful support tool for engineers, reducing the volume of data to deal with, and making the data more meaningful. This paper describes how a multi-agent system for diagnosing the cause of transformer partial discharge activity was coupled with a method of UHF partial discharge monitoring, creating an on-line condition monitoring system. The challenges presented by the on-site environment are discussed, along with the implications for the complete system.

  • PDF

고정자권선의 절연열화 특성분석 (Analysis of the Insulation aging for the stator winding)

  • 오봉근;최교남;한창동;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.23-24
    • /
    • 2006
  • Stator winding of hydro generator is gradually deteriorated by multi-stress and steady degradation of insulation results in insulation breakdown. The region where insulation breakdown occurs in stator winding is part where the multi-stress causes the defect of insulation material and electrical stress has been concentrated. Therefore, we judged locations of insulation breakdown to be varied according to various stress factors in service. In this paper, we drew the stator winding of hydro generators which has run for a long time and separated it into 3 parts(central part, end winding part, drawing part) according to the positions laid on the core. We performed electrical and thermal stress on these specimens for 1000 hrs under the same condition, measured the condition regularlyand analyzed the insulation status of each winding by performing partial discharge test. In addition, we analyzed the trend of partial discharge concerning specimens that caused the insulation breakdown during aging.

  • PDF

박용디젤기관의 대기오염 저감을 위한 전기 다단 임팩션 시스템의 집진특성 (Collection characteristics of electro-static multi-staged impaction system for air pollutants removal of marine diesel engines)

  • 여석준;권준형
    • 수산해양기술연구
    • /
    • 제51권4호
    • /
    • pp.545-552
    • /
    • 2015
  • The main object of this study is to investigate the collection characteristics of an electro-static multi-staged impaction system, experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as the inlet velocity, stage number, applied voltage and shape of discharge electrode, etc. In results, the pressure drop is shown below $148mmH_2O$ lower than that of the conventional bag filter at inlet velocity 3.46 m/s and 5 stage. For 5 stage, the collection efficiencies are to be 97.4, 99.0% with the applied voltage 0 kV at the inlet velocity 2.07, 3.46 m/s, while 98.4, 99.9% with 40 kV of a sharp edge discharge electrode. Additionally, the present system is to be considered as an effective compact system for a removal of particulate pollutants from marine diesel engines due to much higher collection efficiency and appropriate pressure drop.

Assessment of Water Quality using Multivariate Statistical Techniques: A Case Study of the Nakdong River Basin, Korea

  • Park, Seongmook;Kazama, Futaba;Lee, Shunhwa
    • Environmental Engineering Research
    • /
    • 제19권3호
    • /
    • pp.197-203
    • /
    • 2014
  • This study estimated spatial and seasonal variation of water quality to understand characteristics of Nakdong river basin, Korea. All together 11 parameters (discharge, water temperature, dissolved oxygen, 5-day biochemical oxygen demand, chemical oxygen demand, pH, suspended solids, electrical conductivity, total nitrogen, total phosphorus, and total organic carbon) at 22 different sites for the period of 2003-2011 were analyzed using multivariate statistical techniques (cluster analysis, principal component analysis and factor analysis). Hierarchical cluster analysis grouped whole river basin into three zones, i.e., relatively less polluted (LP), medium polluted (MP) and highly polluted (HP) based on similarity of water quality characteristics. The results of factor analysis/principal component analysis explained up to 83.0%, 81.7% and 82.7% of total variance in water quality data of LP, MP, and HP zones, respectively. The rotated components of PCA obtained from factor analysis indicate that the parameters responsible for water quality variations were mainly related to discharge and total pollution loads (non-point pollution source) in LP, MP and HP areas; organic and nutrient pollution in LP and HP zones; and temperature, DO and TN in LP zone. This study demonstrates the usefulness of multivariate statistical techniques for analysis and interpretation of multi-parameter, multi-location and multi-year data sets.