HOT CHANNEL ANALYSIS CAPABILITY OF THE BEST-ESTIMATE MULTI-DIMENSIONAL SYSTEM CODE, MARS 3.0

  • JEONG J.-J.;BAE S. W.;HWANG D. H.;LEE W. J.;CHUNG B. D.
    • Nuclear Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.469-478
    • /
    • 2005
  • The subchannel analysis capability of MARS, a multi-dimensional thermal-hydraulic system code, has been enhanced. In particular, the turbulent mixing and void drift models for the flow-mixing phenomena in rod bundles were improved. Then, the subchannel analysis feature was combined with the existing coupled system thermal-hydraulics (T/H) and 3D reactor kinetics calculation capability of MARS. These features allow for more realistic simulations of both the hot channel behavior and the global system T/H behavior. Using the coupled features of MARS, a coupled analysis of a main steam line break (MSLB) is carried out for demonstration purposes. The results of the calculations are very reasonable and promising.

RECENT IMPROVEMENTS IN THE CUPID CODE FOR A MULTI-DIMENSIONAL TWO-PHASE FLOW ANALYSIS OF NUCLEAR REACTOR COMPONENTS

  • Yoon, Han Young;Lee, Jae Ryong;Kim, Hyungrae;Park, Ik Kyu;Song, Chul-Hwa;Cho, Hyoung Kyu;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.46 no.5
    • /
    • pp.655-666
    • /
    • 2014
  • The CUPID code has been developed at KAERI for a transient, three-dimensional analysis of a two-phase flow in light water nuclear reactor components. It can provide both a component-scale and a CFD-scale simulation by using a porous media or an open media model for a two-phase flow. In this paper, recent advances in the CUPID code are presented in three sections. First, the domain decomposition parallel method implemented in the CUPID code is described with the parallel efficiency test for multiple processors. Then, the coupling of CUPID-MARS via heat structure is introduced, where CUPID has been coupled with a system-scale thermal-hydraulics code, MARS, through the heat structure. The coupled code has been applied to a multi-scale thermal-hydraulic analysis of a pool mixing test. Finally, CUPID-SG is developed for analyzing two-phase flows in PWR steam generators. Physical models and validation results of CUPID-SG are discussed.

2/3 Modulation Code and Its Vterbi Decoder for 4-level Holographic Data Storage (4-레벨 홀로그래픽 저장장치를 위한 2/3 변조부호와 비터비 검출기)

  • Kim, Gukhui;Lee, Jaejin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.10
    • /
    • pp.827-832
    • /
    • 2013
  • Holographic data storage system is affected by two dimensional intersymbol interference and inter-page interference. Especially, for multi-level holographic data storage system, since one pixel contains more than 1 bit, the system is more vulnerable to the error. In this paper, we propose a 2/3 modulation code for 4-level holographic data storage system. The proposed modulation code with error correcting capability could be compensated these interferences. Also, in this paper, we proposed a Viterbi decoder for 2/3 modulation code. The proposed Viterbi decoder eliminates unnecessary calculation. As a result, proposed 2/3 modulation code and Viterbi decoder has shown better performance than conventional one.

Development of a one-dimensional system code for the analysis of downward air-water two-phase flow in large vertical pipes

  • Donkoan Hwang;Soon Ho Kang;Nakjun Choi;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.19-33
    • /
    • 2024
  • In nuclear thermal-hydraulic system codes, most correlations used for vertical pipes, under downward two-phase flow, have been developed considering small pipes or pool systems. This suggests that there could be uncertainties in applying the correlations to accident scenarios involving large vertical pipes owing to the difference in the characteristics of two-phase flows, or flow conditions, between large and small pipes. In this study, we modified the Multi-dimensional Analysis of Reactor Safety KINS Standard (MARS-KS) code using correlations, such as the drift-flux model and two-phase multiplier, developed in a plant-scale air-inflow experiment conducted for a pipe of diameter 600 mm under downward two-phase flow. The results were then analyzed and compared with those based on previous correlations developed for small pipes and pool conditions. The modified code indicated a good estimation performance in two plant-scale experiments with large pipes. For the siphon-breaking experiment, the maximum errors in water flow for modified and original codes were 2.2% and 30.3%, respectively. For the air-inflow accident experiment, the original code could not predict the trend of frictional pressure gradient in two-phase flow as / increased, while the modified MARS-KS code showed a good estimation performance of the gradient with maximum error of 3.5%.

Verification of a two-step code system MCS/RAST-F to fast reactor core analysis

  • Tran, Tuan Quoc;Cherezov, Alexey;Du, Xianan;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1789-1803
    • /
    • 2022
  • RAST-F is a new full-core analysis code based on the two-step approach that couples a multi-group cross-section generation Monte-Carlo code MCS and a multi-group nodal diffusion solver. To demonstrate the feasibility of using MCS/RAST-F for fast reactor analysis, this paper presents the coupled nodal code verification results for the MET-1000 and CAR-3600 benchmark cores. Three different multi-group cross-section calculation schemes are employed to improve the agreement between the nodal and reference solutions. The reference solution is obtained by the MCS code using continuous-energy nuclear data. Additionally, the MCS/RAST-F nodal solution is verified with results based on cross-section generated by collision probability code TULIP. A good agreement between MCS/RAST-F and reference solution is observed with less than 120 pcm discrepancy in keff and less than 1.2% root-mean-square error in power distribution. This study confirms the two-step approach MCS/RAST-F as a reliable tool for the three-dimensional simulation of reactor cores with fast spectrum.

4-Level Balanced Modulation Code for the Mitigation of Two-Dimensional Intersymbol Interference in Holographic Data-Storage Systems (홀로그래픽 데이터 저장장치에서 2차원 심볼 간 간섭을 완화하기 위한 4-레벨 균형 변조부호)

  • Park, Keunhwan;Lee, Jaejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.9
    • /
    • pp.12-17
    • /
    • 2016
  • In the holographic data storage system (HDSS), the data regarding the volume of a storage medium are recorded and read by the page, and the transmission rate and storage capacity can be increased because of two-dimensional, page-oriented data processing; furthermore, the multi-level HDSS can store more than one bit per pixel. For this same reason, however, and unlike conventional data-storage systems, the HDSS is hampered by two-dimensional (2D) intersymbol interference (ISI) and interpage interference (IPI). Progress regarding the published papers on 2D ISI, which is more severe in the multi-level HDSS, continues; however, mitigation of both 2D ISI and IPI in terms of the multi-level HDSS has not yet been studied. In this paper, we therefore propose a 4-level balanced-modulation code that simultaneously mitigates 2D ISI and IPI.

ROSA/LSTF test and RELAP5 code analyses on PWR steam generator tube rupture accident with recovery actions

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.981-988
    • /
    • 2018
  • An experiment was performed for the OECD/NEA ROSA-2 Project with the large-scale test facility (LSTF), which simulated a steam generator tube rupture (SGTR) accident due to a double-ended guillotine break of one of steam generator (SG) U-tubes with operator recovery actions in a pressurized water reactor. The relief valve of broken SG opened three times after the start of intact SG secondary-side depressurization as the recovery action. Multi-dimensional phenomena specific to the SGTR accident appeared such as significant thermal stratification in a cold leg in broken loop especially during the operation of high-pressure injection (HPI) system. The RELAP5/MOD3.3 code overpredicted the broken SG secondary-side pressure after the start of the intact SG secondary-side depressurization, and failed to calculate the cold leg fluid temperature in broken loop. The combination of the number of the ruptured SG tubes and the HPI system operation difference was found to significantly affect the primary and SG secondary-side pressures through sensitivity analyses with the RELAP5 code.

Transient full core analysis of PWR with multi-scale and multi-physics approach

  • Jae Ryong Lee;Han Young Yoon;Ju Yeop Park
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.980-992
    • /
    • 2024
  • Steam line break accident (SLB) in the nuclear reactor is one of the representative Non-LOCA accidents in which thermal-hydraulics and neutron kinetics are strongly coupled each other. Thus, the multi-scale and multi-physics approach is applied in this study in order to examine a realistic safety margin. An entire reactor coolant system is modelled by system scale node, whereas sub-channel scale resolution is applied for the region of interest such as the reactor core. Fuel performance code is extended to consider full core pin-wise fuel behaviour. The MARU platform is developed for easy integration of the codes to be coupled. An initial stage of the steam line break accident is simulated on the MARU platform. As cold coolant is injected from the cold leg into the reactor pressure vessel, the power increases due to the moderator feedback. Three-dimensional coolant and fuel behaviour are qualitatively visualized for easy comprehension. Moreover, quantitative investigation is added by focusing on the enhancement of safety margin by means of comparing the minimum departure from nucleate boiling ratio (MDNBR). Three factors contributing to the increase of the MDNBR are proposed: Various geometric parameters, realistic power distribution by neutron kinetics code, Radial coolant mixing including sub-channel physics model.