• Title/Summary/Keyword: multi-array

Search Result 773, Processing Time 0.029 seconds

Performance of Adaptive array antenna system under the Multi-Rate Service Environment (Multi Rate Service 환경 하에서의 adaptive array antenna system의 성능 분석)

  • 박현화;김정호
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.396-402
    • /
    • 2003
  • 본 논문에서는 multi-media service를 제공하는데 smart antenna system을 적용했을 때의 performance 를 각 서비스별 특성에 따라 평가한다. 서로 다른 다중 rate 의 신호가 각각의 안테나를 통해서 수신되는 환경 하에서 adaptive smart antenna를 적용함으로써 보다 고속이고 향상된 용량의 서비스를 제공할 수 있도록 하기 위해서는 사용자의 지리적 분포 또는 간섭 전력에 따라서 성능 특성이 달라지므로 이에 대한 성능 분석을 시뮬레이션을 통해서 수행한다.

  • PDF

Super Multi-View 3-D Display System using Vibrating Scanner Array(ViSA)

  • Jeon, Ho-In;Jung, Nak-Hee;Choi, Jin-San;Kang, Yo-Seek;Choi, Se-Ha;Shin, Sang-Hun;Son, Jung-Yung
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.37-42
    • /
    • 2000
  • In this paper, we propose a super multi-view (SMV) 3-D display system using a vibrating scanner array (ViSA). The parallel beam scanning using a vibrating scanner array is performed by moving back and forth an array of curvature-compensated mirrors attached to two vibrating membranes. The parallel laser beam scanner array can replace the polygon mirror scanner which has been used in the SMV 3-D display system based on the focused light array(FLA) concept. The proposed system has great advantages in the sense that it requires neither huge imaging optics normechanical scanning parts. Some mathematical analyses and fundamental limitations of the proposed system are presented. The proposed vibrating scanner array, after some modifications and refinements, will replace polygon mirror-based scanners in the near future.

Signal Intensity Changes according to Coil Position Changes in MRI using 6 Channel SENSE Cardiac Array Coils (6채널 SENSE Cardiac Array 코일을 이용한 검사 시 코일의 위치 변화에 따른 신호강도)

  • Choi, Kwan-Woo;Son, Soon-Yong;Yoo, Beong-Gyu
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.699-706
    • /
    • 2018
  • In this study, we measured signal intensities according to array coil position changes to provide reference data of coil directions and the distances as it deters image quality unless the coils are aligned properly. The multi-purpose MRI phantom was placed in body array coils, and it was moved to the top, bottom, left, and right directions by 2 cm from the center to 10 cm. After obtaining images, signal intensities were measured and compared. The results of this study were as follows: Except for the upward direction, the signal intensities of the reference signal was not significantly different from that of the reference signal intensity within 2cm in both T1 and T2-weighted images. In conclusion, in clinical circumstances which various challenges exist to align the coils exactly on the same lines, array coils should be positioned at least within 2 cm from the center except for the upward direction, on the same line to prevent the image qualities are lowered.

Process Design of Multi-Step Drawing using Artificial Neural Network (신경망을 이용한 다단 인발의 공정설계)

  • 김동환;김동진;김병민;최재찬
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.144-147
    • /
    • 1997
  • Process design of multi-step wire drawing process, conducted by means of finite element analysis and ANN(Artificial Neural Network), has been considered. The investigated problem involves the adequate selection of the drawing die angle and the correspondent reduction rate sequence in the condition of desired initial and final diameter. Combinations of the process parameters which are used in finite element simulation are selected by using orthogonal array. Also the orthogonal array and the results of finite element simulation which are related to the process energy are used as train data of ANN. In this study, it is shown that the new technique using ANN is useful method in application to the wide range of metal forming process.

  • PDF

Development of Target Signal Simulator for Towed Line Array Sonar (선배열 예인음탐기 표적신호 시뮬레이터 개발)

  • Son, Kweon;Choi, Jae-Yong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.3
    • /
    • pp.36-43
    • /
    • 2003
  • Multi-target away signal simulator which can simulate the radiated noises of maneuvering targets in a specified ocean range is an essential equipment for the validation of developed towed array sonar system. This simulator should provide realistic multi-channel signals those are required for beamforming on the signal processing unit of towed away system. This paper describes the overall system configuration and signal synthesis techniques for the target radiated noise. And this paper considers why the time delays between target and individual sensors are caused and how to compensate these time delays to individual sensors output. This multi-purpose target simulator could be used for the training of TASS operators.

Simultaneous and Multi-frequency Driving System of Ultrasonic Sensor Array for Object Recognition

  • Park, S.C.;Choi, B.J.;Lee, Y.J.;Lee, S.R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.582-587
    • /
    • 2004
  • Ultrasonic sensors are widely used in mobile robot applications to recognize external environments, because they are cheap, easy to use, and robust under varying lighting conditions. However, the recognition of objects using a ultrasonic sensor is not so easy due to its characteristics such as narrow beam width and no reflected signal from a inclined object. As one of the alternatives to resolve these problems, use of multiple sensors has been studied. A sequential driving system needs a long measurement time and does not take advantage of multiple sensors. Simultaneous and pulse coding driving system of ultrasonic sensor array cannot measure short distance as the length of the code becomes long. This problem can be resolved by multi-frequency driving of ultrasonic sensors, which allows multi-sensors to be fired simultaneously and adjacent objects to be distinguished. Accordingly, this paper presents a simultaneous and multi-frequency driving system for an ultrasonic sensor array for object recognition. The proposed system is designed and implemented using a DSP and FPGA. A micro-controller board is made using a DSP, Polaroid 6500 ranging modules are modified for firing the multi-frequency signals, and a 5-channel frequency modulated signal generating board is made using a FPGA. To verify the proposed method, experiments were conducted in an environment with overlapping signals, and the flight distances for each sensor were obtained from filtering of the received overlapping signals and calculation of the time-of-flights.

  • PDF

Recording and Analysis of Peripheral Nerve Activity Using Multi-Electrode Array (다채널 신경전극 어레이를 이용한 말초 신경신호의 측정 및 분석)

  • Chu, Jun-Uk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2016
  • Reliable recording and analysis of peripheral nerve activity is important to recognize the user's intention for controlling a neuro-prosthetic hand. In this paper, we present a peripheral nerve recording system that consisted of an intrafascicular multi-electrode array, an electrode insertion device, and a multi-channel neural amplifier. The 16 channel multi-electrode array was stably implanted into the sciatic nerve of the rat under anesthesia using the electrode insertion device. During passive movements and mechanical stimuli, muscle and cutaneous afferent signals were recorded with the multi-channel neural amplifier. Furthermore, we propose a spike sorting method to isolate individual neuronal unit. The muscle proprioceptive units were classified as muscle spindle afferents or Golgi tendon organ afferents, and the skin exteroceptive units were categorized as slow adapting afferents or fast adapting afferents. Experimental results showed that the proposed method could be applicable to record and analyze peripheral nerve activity in neuro-prosthetic systems.

Design and Fabrication of Multi-Focusing Microlens Array with Different Numerical Apertures by using Thermal Reflow Method

  • Park, Min-Kyu;Lee, Ho Jun;Park, Ji-Sub;Kim, Mugeon;Bae, Jeong Min;Mahmud, Imtiaz;Kim, Hak-Rin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.71-77
    • /
    • 2014
  • We present design and fabrication of a multi-focusing microlens array (MLA) using a thermal reflow method. To obtain multi-focusing properties with different numerical apertures at the elemental lens of the MLA, double-cylinder photoresist (PR) structures with different diameters were made within the guiding pattern with both photolithographic and partial developing processes. Due to the base PR layer supporting the thermal reflow process and the guiding structure, the thermally reflowed PR structure had different radii of curvatures with lens shapes that could be precisely modeled by the initial volume of the double-cylinder PR structures. Using the PR template, the hexagonally packed multi-focusing MLA was made via the replica molding method, which showed four different focal lengths of 0.9 mm, 1.1 mm, 1.6 mm, and 2.5 mm, and four different numerical apertures of 0.1799, 0.2783, 0.3973, and 0.4775.

Two-dimensional Localization of Array Elements Placed on a Sea Floor Using M-sequence Signal in Multipath Ocean Environment (M-계열 송신 신호를 이용한 다중 경로 해양 환경에서의 해저면 설치 선배열 센서의 2차원 위치 추정)

  • 오택환;나정열;석동우
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.686-694
    • /
    • 2002
  • This paper proposes an algorithm for estimating positions of array elements placed on a sea floor using acoustic signal in multipath ocean environment. The positions of array elements are estimated by using the travel times of m-sequence signal influenced by the multi-paths environment. The horizontal distance between source and receiver calculated based on the ray model. The proposed paper the algorithm is verified by both simulation data and field experiment in the Bast Sea.

Development of a position sensitive CsI(Tl) crystal array

  • Shi, Guo-Zhu;Chen, Ruo-Fu;Chen, Kun;Shen, Ai-Hua;Zhang, Xiu-Ling;Chen, Jin-Da;Du, Cheng-Ming;Hu, Zheng-Guo;Fan, Guang-Wei
    • Nuclear Engineering and Technology
    • /
    • v.52 no.4
    • /
    • pp.835-840
    • /
    • 2020
  • A position-sensitive CsI(Tl) crystal array coupled with the multi-anode position sensitive photomultiplier tube (PS-PMT), Hamamatsu H8500C, has been developed at the Institute of Modern Physics. An effective, fast, and economical readout circuit based on discretized positioning circuit (DPC) bridge was designed for the 64-channel multi-anode flat panel PSPMT. The horizontal and vertical position resolutions are 0.58 mm and 0.63 mm respectively for the 1.0 × 1.0 × 5.0 ㎣ CsI(Tl) array, and the horizontal and vertical position resolutions are 0.86 mm and 0.80 mm respectively for the 2.0 × 2.0 × 10.0 ㎣ CsI(Tl) array. These results show that the CsI(Tl) crystal array with low cost could be applied in the fields of medical imaging and high-resolution gamma camera.