• Title/Summary/Keyword: multi sources

Search Result 620, Processing Time 0.036 seconds

Simultaneous 22GHz Water and 44GHz Methanol Maser Survey of Low-mass Protostars

  • Kim, Kee-Tae;Youn, So-Young;Bae, Jae-Han;Lee, Jeong-Eun;Choi, Yun-Hee;Evans, Neal
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.109.2-109.2
    • /
    • 2011
  • We have carried out a multi-epoch, simultaneous 22GHz $H_2O$ and 44GHz class I $CH_3OH$ maser survey of 109 low-mass protostars. $H_2O$ maser emission was detected in 23 sources, while $CH_3OH$ maser emission in 12 sources. Eight of the $CH_3OH$ detected sources are new detections. For comparison, only four low-mass protostars have been previously found to emit the maser emisison. We investigate difference between the properties of the two masers, such as relative velocity with respect to molecular gas and variability. We also compare the isotropic luminosities of both masers with the bolometric luminosity of the central star.

  • PDF

Pilot observations of VLBI fringe survey at 43 GHz using VERA

  • Oh, Jung-Hwan;Lee, Sang-Sung;Honma, Mareki;Kovalev, Y.Y.;Petrov, Leonid;Sohn, Bong-Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.60.1-60.1
    • /
    • 2011
  • We present the preliminary results of the pilot observations for the fringe survey at 43 GHz with the VLBI Exploration of Radio Astrometry (VERA). The main goals of the fringe survey are to establish a full list of phase calibrators for the VERA dual-beam astrometric observations, and for the KVN multi-frequency phase referencing observations. We performed two 24 hours experiments as a pilot observation to test the feasibility of the fringe survey. Each source from a list of 220 sources has been observed in one scan for 2 minutes. 67 sources were detected with the SNR threshold of 3.5. The correlated flux densities of the detected sources are presented in four ranges of projected baseline lengths.

  • PDF

Asymmetric Cascaded Multi-level Inverter: A Solution to Obtain High Number of Voltage Levels

  • Banaei, M.R.;Salary, E.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.316-325
    • /
    • 2013
  • Multilevel inverters produce a staircase output voltage from DC voltage sources. Requiring great number of semiconductor switches is main disadvantage of multilevel inverters. The multilevel inverters can be divided in two groups: symmetric and asymmetric converters. The asymmetric multilevel inverters provide a large number of output steps without increasing the number of DC voltage sources and components. In this paper, a novel topology for multilevel converters is proposed using cascaded sub-multilevel Cells. This sub-multilevel converters can produce five levels of voltage. Four algorithms for determining the DC voltage sources magnitudes have been presented. Finally, in order to verify the theoretical issues, simulation is presented.

Cascaded H-bridge Multilevel Inverter employing Front-end Flyback Converter with Single Independent DC Voltage Source

  • Kim, Ki-Du;Bae, Gyou-Tak;Kang, Feel-Soon
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.197-201
    • /
    • 2013
  • Cascaded H-bridge multilevel inverter requires independent DC voltage sources to produce multi output voltage levels. When it needs to generate more levels in the output voltage wave, the number of independent DC voltage sources usually limits its extension. To solve this problem, we propose a cascaded H-bridge multilevel inverter employing a front-end flyback converter for unifying input DC voltage sources. After theoretical analysis of the proposed circuit, we verify the validity of the proposed inverter using computer-aided simulations and experiments.

Neutrino Astronomy with Korean Neutrino Observatory

  • Kwak, Kyujin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.29.3-29.3
    • /
    • 2018
  • Neutrino astronomy is now possible as the technology to detect neutrinos has been advancing. Current and planned neutrino-detecting facilities can be operated as a conventional telescope because they can measure the direction toward the celestial sources as well as their physical properties like energy. Together with gravitational wave, neutrino astronomy opens a new field of astronomy, often called, multi-messenger astronomy, which also involves "traditional" electro-magnetic-wave-detection-based astronomy. Expecting that Korean Neutrino Observatory (KNO) will be one of the best neutrino observatories when it is constructed, a group of Korean astronomers and astrophysicists formed a working group and began to investigate possible astronomical neutrino sources that could be detected by KNO and other neutrino observatories. This talk presents the recent activities of the working group and introduces the list of possible neutrino sources.

  • PDF

Uncertainty Analysis for the Multi-path Ultrasonic Flowmeter UR- 1000 with Dry Calibration (간접 교정에 의한 다회선 초음파유량계 UR-1000 불확도 분석)

  • Hwang, Shang-Yoon;Park, Sung-Ha;Park, Kyung-Am
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.378-386
    • /
    • 2002
  • Multi-path ultrasonic Sow measurement system uncertainty is determined by assigning an expected error of each component of flow measurement and then defining the total flow measurement uncertainty as square root of the sum of squared values of the individual error. Sources of uncertainty for flow measurement are geometry, transit time and velocity profile integration uncertainty. A theoretical uncertainty model for multi-path ultrasonic transit time flowmeter configured with parallel 5 chords, is derived from and calculated by dry calibration method.

  • PDF

OFEX Controller to Improve Queueing and User Performance in Multi-bottleneck Networks

  • Liu, Jungang;Yang, Oliver W.W.
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.396-406
    • /
    • 2014
  • We have designed and investigated a new congestion control scheme, called optimal and fully explicit (OFEX) controller. Different from existing relatively explicit controllers, this new scheme can provide not only optimal bandwidth allocation but also a fully explicit congestion signal to sources. It uses the congestion signal from the most congested link instead of the cumulative signal from the flow path. In this way, it overcomes the drawback of relatively explicit controllers exhibiting bias toward multi-bottlenecked users and significantly improves their convergence speed and source throughput performance. Furthermore, our OFEX-controller design considers a dynamic model by proposing a remedial measure against the unpredictable bandwidth changes in contention-based multi-access networks. Compared with former works/controllers, this remedy also effectively reduces the instantaneous queue size in a router and thus significantly improves queuing delay and packet loss performance. We have evaluated the effectiveness of the OFEX controller in OPNET. The experimental comparison with the existing relatively explicit controllers verifies the superiority of our new scheme.

The control of Interleaved Multi-phase Boost Converter for Application of a Fuelcell Railway Vehicle (연료전지 철도차량 적용을 위한 인터리브드 다상 승압형 컨버터 제어)

  • Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1925-1930
    • /
    • 2016
  • Fuel cell power generation system, unlike conventional energy sources, converts chemical energy into electrical energy through electrochemical reaction of hydrogen and oxygen. This paper presents the control of interleaved multi-phase boost converter as the feasibility study on small-scale prototype electric railway vehicle application using fuel cell generation system. PSIM simulation program is to be used to implement the modeling of the electrical fuelcell as well as traction motor control with interleaved multi-phase boost converter. Comparing the input current ripple rate, two-phase interleaved boost converter is less than the boost converter. But the more multi-phase not less proportional to the ripple factor. we confirmed that the amplitude of the input current ripple rate of converter depend on duty ratio.

Energy Conversion System using a Novel Multi-Mode DC/DC Converter for Hybrid Electric Vehicles (새로운 멀티 모드 DC-DC 컨버터를 이용한 하이브리드 전기자동차용 전력변환 시스템)

  • Park, Tae-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.192-198
    • /
    • 2013
  • The rapidly growing demand for electric power systems in electric vehicles (EVs) and hybrid electric vehicles (HEVs) require simpler, cost-effective, and higher performance components. In this paper, a novel power conversion system for hybrid electric vehicles is proposed for these needs. The proposed power conversion system reduces the conversion system cost while preserving same functionality. The proposed power conversion system can boost multi-sources to drive a traction motor and to store energy at the same time reducing number of switching components. In this paper, all operational modes of the proposed converter are explained in detail and verified by a computer simulation first. Then, the topology and operational modes are experimentally verified. Based on the results, the feasibility of the proposed multi-mode single leg power conversion system for EV and HEV applications is discussed.

Signal Processing Method for Noise Reduction of Multi-Axis Force Sensors (다축힘센서의 노이즈신호 개선을 위한 신호처리 방법)

  • 김용찬;강철구;남현도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1026-1029
    • /
    • 2003
  • There are always some errors in force sensing of multi-axis force sensors that aggravate sensor performance. Error sources may be classified mainly in two groups. One is structural error due to inaccuracy of sensor body, and the other is error due to noise signals existing in the sensed information. This paper presents a brief review about the principle of multi-axis force sensors, and then a method that can reduce the effect of noise signals. The method is to read digital signals in computer instead of analog voltage signals. We can eliminate the bad effect of electromagnetic waves emitted from computer and of 60 Hz noise emitted from AC source by the proposed method. The proposed method is investigated through experimental demonstration. The experimental results show the proposed method improves the sensor performance significantly.

  • PDF