• Title/Summary/Keyword: motors

Search Result 3,612, Processing Time 0.039 seconds

Remote control of spent nuclear fuel handling equipment with fuzzy logic (사용후 핵연료 원격 취급 장치의 퍼지 제어)

  • 김기준;김호동;윤완기;이재설
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.911-916
    • /
    • 1991
  • Spent nuclear fuel is highly radioactive and requires remote operation due to radiation exposure. Motors which have been used in the highly radioactive environments are a DC type because of their easy implementation on control system. However there are some problems such as mechanical maintenance of brush and commutator, high cost, and heavy material control. AC servo motors are applied and tested on fuzzy and conventional control algorithms. Fuzzy logic controls of AC servo give adequate control accuracy and power for spent fuel handling in radioactive environments.

  • PDF

Computerization of Ultrasonic Scanner (초음파 주사장치의 Computer화)

  • Kim, Young-Hwan;Kim, Young-Gil;Lee, Se-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.15-19
    • /
    • 1985
  • Computerization of ultrasonic scanner is considered to achieve more quantitative and reliable ultrasonic testing. Testech LS-24 ultrasonic scanner is modified, and step motors in this modified ultrasonic scanner are driven by multiprogrammer controlled by computer. Two step motors can be controlled independently and simultaniously. The performance of computerized ultrasonic scanner is examined entloying modified C scan for a flat bottom hole ultrasonic reference block.

  • PDF

The development of mobile robot for hostile environment controlled by three motors (3개의 모터로 구동되는 극한작업용 이동로보트의 개발)

  • 권대갑;차영엽;염도성
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.704-709
    • /
    • 1990
  • This study presents the structure and the gate control algorithm of KAMOBOT (KAIST Mobile Robot). The mobile robot has a six-legged, cylindrical configuration, each leg of which is equiped with a wheel at the bottom. The robot can go up and down stairs, go over obstacles, move along curvilinear paths and rotate around it's geometric center. Such maneuverability can be achieved by using only three electric motors.

  • PDF

Nonlinear digital position control of brushless DC motors for direct drive robot (브러쉬없는 직류전동기의 비선형 디지탈 위치제어)

  • 홍기철;남광희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.252-257
    • /
    • 1990
  • For the position control of BL-DC motors, 2.phi.-3.phi. conversion unit, hysteresis band device, and PWM pulse generation are required. By utilizing a single-chip processor INTEL 8097BH, we cover all required functions. As a result, no analogue device is employed in this control scheme, so that it makes BL-DC motor controller simple and flexible. Furthermore, the single-chip processor is utilized for the nonlinear coordinate transformation which is necessary for the linearization of the motor system.

  • PDF

A Survey Study on International Standards of High Efficient Motors (고효율전동기의 국제표준에 관한 조사분석)

  • Hwang, Sung-Wok;Won, Jong-Ryul;Baek, Jung-Myoung;Lee, Byung-Ha;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.225-226
    • /
    • 2008
  • In this paper, some international standards such as IEC of hight efficient motors are analyzed to apply for the estimation of energy saving and $CO_2$ reduction. These international standards are correspond to Korean Standard (KS), especially KSC4202, KSC4203, KSC4204, KSCIEC60034-2, KSCIEC61972.

  • PDF

Analytic Issues for Trend Management on Insulation Diagnositic for High Voltage Motors (고압전동기 절연진단 결과 추이관리의 문제점 분석)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2052-2053
    • /
    • 2008
  • High voltage motors are the core equipment of electric generation facilities and need to guarantee stable operation. Therefore, keeping healthy state is of importance by means of insulation diagnosis periodically. However, if the diagnosis went through in the different circumstances such as temperature, humidity, and impedance applied to the test equipment, the trend analysis have no significance. This paper presents the experimental results supporting the importance of keeping the same conditions under insulation diagnosis.

  • PDF

A Survey on the Load Profiles of the Power Transformers and Motors in Apartment Housing (아파트에서의 동력부하 운전실태 조사)

  • 이기홍;추성두;정지열;안명선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.55-59
    • /
    • 2000
  • This paper gives various load profiles of power transformers and motors in apartment housing. The load profile of power transformer shows that it is peaked in winter by heating system, and the maximum value of load profiles in power transformer is ranged 25%∼35%, which shows it is operated on over-capacity. The maximum value of demand factor in water supply system is about 60% and this of wastewater treatment system is about 50%.

  • PDF

Design of Ultrasonic Linear Motor for X-Y Stage (X-Y 스테이지를 위한 초음파 리니터 모터의 설계)

  • 김태열
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.316-320
    • /
    • 2000
  • An ultrasonic linear motor was composed of a slider and a stator vibrator including piezoelectric material and elastic material. The ultrasonic linear motors mainly consist of an ultrasonic oscillator which generates elliptical oscillations. Elliptical oscillations are generated by synthesizing two degenerated modes. The design of a stator for an Ultrasonic linear motor was optimized with respect to vibration mode and direction of vibratory displacement by employing the finite element method. The motors were designed by varying the width of stator vibrator and the thickness, the length and the position of piezoceramics.

  • PDF

SPEED CONTROL FOR ULTRASONIC MOTORS USING FUZZY ON-LINE TUNING SYSTEM

  • Senjyu, Tomonobu;Gushiken, Yoshiniko;Uezato, Katsumi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.125-130
    • /
    • 1998
  • This paper presents a speed control for ultrasonic motors using a PI controller and disturbance torque observer. Since the PI gains and the observer's poles are generally fixed, the control performance deteriorates when the driving conditions vary much. Therefore, we propose the speed control scheme that the PI gains and the observer's poles are adjusted on-line in accordance with the speed ripple using fuzzy reasoning.

  • PDF