• Title/Summary/Keyword: motor handpiece

Search Result 13, Processing Time 0.017 seconds

AN EVALUATION OF ROTATIONAL STABILITY IN ENDODONTIC ELECTRONIC MOTORS (근관치료용 전기모터의 회전 안정성 평가)

  • Park, Se-Hee;Seo, Hyun-Woo;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.4
    • /
    • pp.246-256
    • /
    • 2010
  • The purpose of this study was to evaluate a rotational stability of endodontic electronic motors by comparing the changes of rotational speed, depending on the number of usages and with/without static load. Twelve new endodontic electronic motors were used in this study. Non contact type digital tachometer was used for measuring the rotational speed of handpiece. True RMS Multimeter was used for measuring the voltages and the electric currents. All measurements were recorded every 10 seconds during 10 minutes and repeated 9 times. Five repetition was done per each electronic motor. To statistical analysis, student t-test, repeated measures and Scheffe's post-hoc tests were performed. In the same motor group, there was no significant difference in all measurements. In all groups, there was no significant difference in the amount of rotational speed changes depending on the number of usages and with/without static load. In the limitation of this study, the results showed that all kinds of endodontic electronic motors in this study had an established rotational stability. Therefore they could be safely used in root canal treatment with a reliable maintenance of rotational speed, regardless of the number of usages and with/without load.

The Evaluation of RPM Change in X-Smart According to Power Source: Endodontic Wireless Electronic Motor (근관치료용 무선전기모터인 X-Smart의 전원의 종류에 따른 RPM 변화의 평가)

  • Park, Se-Hee;Jeong, Dong-Bin;Cho, Kyung-Mo;Kim, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.91-97
    • /
    • 2011
  • The purpose of this study was to evaluate RPM maintenance in X-Smart according to the power supplied by the AC adapter and rechargeable battery. Five new X-Smart were used in this study. A handpiece with rubber disk which has reflective tape was mounted on the vice. To measure the RPM, a non-contact type digital tachometer was used. RPM measurements were recorded every 5 minutes to 180 minutes and repeated 3 times per motor from each power source. To evaluate a difference of the RPM changes, two-way repeated measures were performed using $SPSS^{TM}$ 14.0. All tests were conducted at the 95 percent confidence level. There was no significant difference in the RPM change between the power sources. Continuous use of X-Smart with a rechargeable battery for up to 180 minutes could be safely used as an endodontic wireless motor with a reliable RPM maintenance.

Comparison of screw-in effect of three NiTi file systems used by undergraduates (학생들이 사용한 세 종류 NiTi file systems의 screw-in effect 비교)

  • Oh, Seung-Hei;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.6
    • /
    • pp.477-484
    • /
    • 2006
  • The purposes of this study were to compare the apical terminus width of simulated curved root canal prepared with three NiTi file systems used by undergraduates for evaluation the effects of flute angle and pitch or radial land on reducing screw-in effect and to determine more safe NiTi file system for inexperienced operators. Fifty inexperienced undergraduate students prepared 150 simulated curved root canals in resin blocks with three NiTi file systems ; ProFile$^{(R)}$, Hero Shaper$^{(R)}$, K3$^{TM}$. The electric motor set at a speed of 300 rpm and torque of 30 in a 16 : 1 reduction handpiece was used. The simulated root canal was prepared to ISO #25 sizes with each file system. The scanned images of pre- and post-instrumented canal of resin block were superimposed. To evaluate the screw-in effect of three NiTi file systems, apical terminus width of root canal was measured from superimposed images and statistical analysis was performed. There were significant differences in three NiTi flle systems. ProFile$^{(R)}$ had significantly smaller width than Hero Shaper$^{(R)}$ and K3$^{TM}$"" (P < 0.05), but no significant difference was observed between K3$^{TM}$ and Hero Shaper$^{(R)}$. Under the condition of this study, active file system (Hero SHaper$^{(R)}$, K3$^{TM}$) with variable pitch and helical angle had more screw-in effect than passive file system (ProFile$^{(R)}$) with constant pitch and helical angle. It seems that the radial lands play more important role in reducing screw-in effect.