The Evaluation of RPM Change in X-Smart According to Power Source: Endodontic Wireless Electronic Motor |
Park, Se-Hee
(Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University)
Jeong, Dong-Bin (Department of Information Statistics, College of Natural Sciences, Gangneung-Wonju National University) Cho, Kyung-Mo (Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University) Kim, Jin-Woo (Department of Conservative Dentistry, College of Dentistry, Gangneung-Wonju National University) |
1 | Mounce R. The heartache of separation. Dent Today 2003;22;83-5. |
2 | Pruett JP, Clement DJ, Carnes DL Jr. Cyclic fatigue testing of nickel titanium endodontic instruments. J Endod 1997;23:77-85. DOI ScienceOn |
3 | Ramirez-Salomon M, Soler-Bientz R, de la Garza-Gonzalez R, Palacios-Garza CM. Incidence of Lightspeed separation and the potential for bypassing. J Endod 1997;23:586-7. DOI ScienceOn |
4 | Bryant ST, Thompson SA, Al-Omari M, Dummer PMH. Shaping ability of ProFile rotary nickel-titanium instruments with ISO sized tips in simulated root canals. Part 1. Int Endod J 1998;31:275-81. |
5 | Barbakow F, Lutz F. The Lightspeed preparation technique evaluated by Swiss clinicians after attending continuing education courses. Int Endod J 1997;30:46-50. DOI |
6 | Mandel E, Adib-Yazdi M, Benhamou L-M, Lachkar T, Mesgouez C, Sobel M. Rotary Ni-Ti ProFile systems for preparing curved canals in resin blocks: influence of operator on instrument breakage. Int Endod J 1999;32:436-43. DOI |
7 | Yared GM, Bou Dagher FE, Machtou P. Influence of rotational speed, torque, and operator's proficiency on ProFile failures. Int Endod J 2001;34:47-53. DOI ScienceOn |
8 | Gabel WP, Hoen M, Steiman HR, Pink FE, Dietz R. Effect of rotational speed on nickel-titanium file distortion. J Endod 1999;25:752-4. DOI ScienceOn |
9 | Yared GM, Bou Dagher FE, Machtou P, Kulkarni GK. Influence of rotational speed, torque and operator proficiency on failure of Greater Taper files. Int Endod J 2002;35:7-12. DOI ScienceOn |
10 | Gambarini G. Cyclic fatigue of nickel-titanium rotary instruments after clinical use with low- and high-torque endodontic motors. J Endod 2001;27:772-4. DOI ScienceOn |
11 | Yared G, Sleiman P. Failure of ProFile instruments with air, high torque control and low torque control motors. Int Endod J 2001;34:471-5. DOI ScienceOn |
12 | Gambarini G. Cyclic fatigue of ProFile rotary instruments after prolonged clinical use. Int Endod J 2001;34:386-9. DOI ScienceOn |
13 | Yared GM, Bou Dagher FE, Machtou P. Cyclic fatigue of Profile rotary instruments after simulated clinical use. Int Endod J 1999;32:115-9. DOI ScienceOn |
14 | Yared GM, Bou Dagher FE, Machtou P. Cyclic fatigue of Profile rotary instruments after clinical use. Int Endod J 2000;33:204-7. DOI ScienceOn |
15 | Blum JY, Machtou P, Micallef JP. Location of contact areas on rotary Profile instruments in relationship to the forces developed during mechanical preparation on extracted teeth. Int Endod J 1999;32:108-14. DOI ScienceOn |
16 | Thompson SA, Dummer PM. Shaping ability of ProFile .04 Taper Series 29 rotary nickel-titanium instruments in simulated root canals. Part 2. Int Endod J 1997;30:8-15. DOI |
17 | Thompson SA, Dummer PM. Shaping ability of Quantec Series 2000 rotary nickel-titanium instruments in simulated root canals. Part 1. Int Endod J 1998;31:259-67. |
18 | Cohen S, Burns RC. Pathways of the pulp. 8th ed. St. Louis: Mosby-Year Book, Inc., 2002:533-4. |
19 | Yared GM, Bou Dagher FE, Kulkarni GK. Influence of torque control motors and the operator' proficiency on ProTaper failures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2003;96:229-33. DOI ScienceOn |
20 | Berutti E, Negro AR, Lendini M, Pasqualini D. Influence of manual preflaring and torque on the failure rate of ProTaper rotary instruments. J Endod 2004;30:228-30. DOI ScienceOn |
21 | Bahia MGA, Martins RC, Gonzalez BM, Buono VTL. Physical and mechanical characterization and the influence of cyclic loading on the behavior of nickel-titanium wires employed in the manufacture of rotary endodontic instruments. Int Endod J 2005;38:795-801. DOI ScienceOn |
22 | Li UM, Lee BS, Shih CT, Lan WH, Lin CP. Cyclic fatigue of endodontic nickel-titanium rotary instruments: static and dynamic tests. J Endod 2002;28:448-51. DOI ScienceOn |
23 | Zelada G, Varela P, Martn B, Bahllo JG, Magn F, Ahn S. The effect of rotational speed and the curvature of root canals on the breakage of rotary endodontic instruments. J Endod 2002;28:540-2. DOI ScienceOn |
24 | Martn B, Zelada G, Varela P, et al. Factors influencing the fracture of nickel-titanium rotary instruments. Int Endod J 2003;36:262-6. DOI ScienceOn |
25 | Dietz DB, Di Fiore PM, Bahcall JK, Lautenschlager EP. Effect of rotational speed on the breakage of nickel-titanium rotary files. J Endod 1998;26:68-71. |
26 | Poulsen WB, Dove SB, Del Rio CE. Effect of nickel-titanium engine driven instrument rotational speed on root canal morphology. J Endod 1995;21:609-12. DOI ScienceOn |
27 | Petka K, Implementing one-visit root canal therapy. Dent Today 1998;17:112-7 |
28 | Operation manual of X-Smart. Dentsply 2006;22 |
29 | Kobayashi C, Yoshioka T, Suda H. A new engine-driven canal preparation system with electronic canal measuring capability. J Endod 1997;23:751-4. DOI ScienceOn |