• Title/Summary/Keyword: motion blurring

Search Result 53, Processing Time 0.026 seconds

Image Enhancement System Of FPD Using Adaptive ODC (적응형 ODC를 이용한 FPD의 화질향상 시스템)

  • 최성원;서범석;권병헌
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.533-536
    • /
    • 2003
  • In this paper we propose AODC(Adaptive Over Driving Circuit) to reduce motion blurring and compensate color accuracy on LCD monitor. The proposed method has been experimented on adaptive ODC by motion grade after detection of moving objects. Also, we discriminated motion grade by mean value's degree of differential value between current frame and previous frame to detect moving objects. It has been found that the proposed method provides better performance than the conventional one from the point of view on the blurring of movement objects through the experiment. Its results show that the proposed method is very suitable for a motion blurring reduction on LCD monitor.

  • PDF

Improvement of Ultrasound Images Using Motion Estimation and Recursive Filtering (Motion Estimation과 Recursive Filtering을 사용한 초음파 동화상의 개선)

  • Song, J.S.;Lee, J.K.;Yang, Y.J.;Choi, H.J.;Oh, C.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.123-126
    • /
    • 1995
  • The purpose of this paper is to improve ultrasound images using motion estimation and recursive filtering. Although averaging without motion correction can make image blurring, the proposed estimation method improves image SNR without motion blurring by recursively averaging images with motion correction. Computer simulation on the proposed method has been performed to improve phantom and ultrasound fish images and the results show the utility of the proposed method.

  • PDF

A Low Motion Blurring Algorithm on FPD systems

  • Yun, Jong-Ho;Kwon, Byong-Heon;Choi, Myung-Ryul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.183-186
    • /
    • 2003
  • We propose a new interpolation algorithm that can effectively decrease motion blurring on moving image. The proposed algorithm can be easily applied to FPD systems, since its structure is very simple. The proposed algorithm has been simulated and verified for image definition and sharpness, quantitatively and qualitatively. The simulation result shows that the proposed method provides better performance than the conventional ones..

  • PDF

Optimal Respiratory Ordering Scheme (OROS) for Correcting Blurring Artifacts in Abdominal Magnetic Resonance Imaging (복부 핵자기공명 영상에서 영상번짐의 교정을 위한 최적 호흡 정렬법)

  • Jung, Kwan-Jin;Ahn, Woo-Youn;Cho, Zang-Hee
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1990 no.11
    • /
    • pp.15-18
    • /
    • 1990
  • In abdominal NMR imaging the respiratory ordering techniques have been successfully used to remove the ghosting artifacts arising from the respiratory motion. In the existing respiratory ordering schemes, however, it is generally accepted that blurring of the moving parts still remains as in the signal averaging technique. A new optimal respiratory ordering scheme which can correct the blurring as well as the ghosting artifacts is theoretically derived through the analysis of the phase encoding directional motion effects in Fourier imaging. The performance of the optimal respiratory ordering scheme is experimentally confirmed together with a suboptimal ordering scheme which is suggested as a compromise for the practicality.

  • PDF

Fast Patch-based De-blurring with Directional-oriented Kernel Estimation

  • Min, Kyeongyuk;Chong, Jongwha
    • Journal of IKEEE
    • /
    • v.21 no.1
    • /
    • pp.46-65
    • /
    • 2017
  • This paper proposes a fast patch-based de-blurring algorithm including kernel estimation based on the angle between the edge and the blur direction. For de-blurring, image patches from the most informative edges in the blurry image are used to estimate a kernel with low computational cost. Moreover, the kernels of each patch are estimated based on the correlation between the edge direction and the blur direction. This makes the final kernel more reliable and creates an accurate latent image from the blurry image. The combination of directionally oriented kernel estimation and patch-based de-blurring is faster and more accurate than existing state-of-the art methods. Experimental results using various test images show that the proposed method achieves its objectives: speed and accuracy.

Laboratory Test Method for the Forward Motion Compensation of Airborne Camera (항공용 카메라 전방운동 보상기능의 실험실 입증방안)

  • Song, Dae-Buem;Yoon, Yong-Eun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.507-512
    • /
    • 2012
  • Image blurring in airborne camera can be prevented through timely actuation of LOS(Line of Sight) into the opposite direction to the aircraft advancement, i.e. FMC(Forward motion compensation). Performance verification of FMC requires installation of camera to the aircraft. However, in many ways the verification process has little choice but to be implemented in the laboratory. In this paper verification method of FMC performance in the laboratory is introduced. With collimator target installed in the known reference position image obtained by actual mission plan naturally displays image blurring as well as LOS displacement by FMC effect. Through comparison of the amount of those image blurring and LOS displacement to the equivalent image distortion expected by the application of the FMC reference command can the performance be verified. In this paper we propose a new verification method of FMC performance in laboratory along with generalized solution of FMC reference command, and assess the validity of our proposition.

Motion Image Restoration by Inverse Filtering (역 필터링을 이용한 이동물체 영상복원)

  • 김영우;유광렬;이대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.2
    • /
    • pp.176-188
    • /
    • 1987
  • This paper presents a method for Digital Image Motion Restoration by inverse filtering. In order to onstruct optimal Restoration filter, We exactly have to model the degradation process, and therefrom, derive the inverse filter which has inverse charateristics of the degradation model. An Image taken from object which moves fast, is o suffer blurring. it can be modeled by integration process mathematically and analyzed to convolve a rectangular window over an image. in this paper, We analyzed it in the frequency domain, and studied a method for motion restoration using inverse filter has a directional Sinc property.

  • PDF

Improvement of Radar Images Using Time-Frequency Transform (시간-주파수 영역 해석법을 이용한 레이더 영상 품질 개선에 대한 연구)

  • Jung, Sang-Won;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.1
    • /
    • pp.14-19
    • /
    • 2010
  • In this paper, an efficient algorithm is developed to perform target rotational motion compensation to achieve the clear inverse synthetic aperture radar(ISAR) image. The algorithm is based on a time-frequency technique. This algorithm provides an efficient method to resolve the blurring image caused by the time-varying behavior of the target scattering centers and leads to a well-focused ISAR image. Results demonstrate that the time-frequency techniques can improve the blurring ISAR image when an aircraft is in complex motion, such as maneuvering, rotation and acceleration.

A Method for Projecting Multiple Stripe Patterns for High Precision 3D Measurement (고정밀 3차원 측정을 위한 다중 줄무늬 투영 방법에 관한 연구)

  • Chang, Min-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.58-63
    • /
    • 2007
  • This paper proposes a novel method of projecting a multiple stripe pattern whose intensity profile is sinusoidal. The sinusoidal stripe patterns are plated with chromium on a piece of glass, and the glass is placed within an optical projection system. By linearly moving the glass along the direction of the stripe pattern, the projection system generates the motion blurring effect, and as a result, produces a blurred stripe pattern whose intensity profile is sinusoidal along the perpendicular direction of the stripe pattern. The sinusoidal pattern improves the measurement accuracy of phase-shifting method. Experimental results are provided for three different types of stripe patterns: rectangle, diamond, and sinusoid.

Image quality and usefulness evaluaton of 3D-CBCT and Gated-CBCT according to baseline changes for SBRT of Lung Cancer (폐암 환자의 정위체부방사선치료 시 기준선 변화에 따른 3D-CBCT(Cone Beam Computed-Tomography)와 Gated-CBCT의 영상 품질 및 유용성 평가)

  • Han Kuk Hee;Shin Chung Hun;Lee Chung Hwan;Yoo Soon Mi;Park Ja Ram;Kim Jin Su;Yun In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.41-51
    • /
    • 2023
  • Purpose: This study compares and analyzes the image quality of 3D-CBCT(Cone Beam Computed-Tomography) and Gated CBCT according to baseline changes during SBRT(Stereotactic Body RadioTherapy) in lung cancer patients to find a useful CBCT method for correcting movement due to breathing Materials and methods : Insert a solid tumor material with a diameter of 3 cm into the QUASARTM phantom. 4-Dimentional Computed-Tomography(4DCT) images were taken with a speed of the phantom at period 3 sec and a maximum amplitude of 20 mm. Using the contouring menu of the computerized treatment planning system EclipseTM Gross Tumor Volume was outlined on solid tumor material. Set-up the same as when acquiring a 4DCT image using Truebeam STxTM, breathing patterns with baseline changes of 1 mm, 3 mm, and 5 mm were input into the phantom to obtain 3D-CBCT (Spotlight, Full) and Gated-CBCT (Spotlight, Full) images five times repeatedly. The acquired images were compared with the Signal-to-Noise Ratio(SNR), Contrast-to-Noise Ratio(CNR), Tumor Volume Length, and Motion Blurring Ratio(MBR) based on the 4DCT image. Results: The average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Spotlight Gated CBCT images were 13.30±0.10%, 7.78±0.16%, 3.55±0.17%, 1.18±0.06%. As a result, Spotlight Gated-CBCT images according to baseline change showed better values than Spotligtht 3D-CBCT images. Also, the average Signal-to-Noise Ratio, Contrast-to-Noise Ratio, Tumor Volume Length and Motion Blurring Ratio of Full Gated CBCT images were 12.80±0.11%, 7.60±0.11%, 3.54±0.16%, 1.18±0.05%. As a result Full GatedCBCT images according to baseline change showed better values than Full 3D-CBCT images. Conclusion : Compared to 3D-CBCT images, Gated-CBCT images had better image quality according to the baseline change, and the effect of Motion Blurring Artifacts caused by breathing was small. Therefore, it is considered useful to image guided using Gated-CBCT when a baseline change occurs due to difficulty in regular breathing during SBRT that exposes high doses in a short period of time

  • PDF