• Title/Summary/Keyword: monochrome

Search Result 88, Processing Time 0.04 seconds

Next-generation active-matrix polymer OLED displays

  • Vaart, N.C. Van Der;Meulenkamp, E.A.;Young, N.D.;Fleuster, M.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.337-342
    • /
    • 2004
  • Since 1992, Philips has been developing polymer OLEDs resulting in a first commercial monochrome display just 10 years later. Philips is now focusing on the technology development required to mass-produce full-color polymer OLDE displays, based on passive and active-matrix addressing. High precision inkjet printing has been chosen as the deposition technology for the OLED material. In this paper, we give an overview of the activities of Philips in the area of mobile OLED applications and explore the route towards large screen OLED television.

  • PDF

Theoretical study of the optical properties of low voltage stacked cholesteric liquid-crystal displays

  • Valyukh, Iryna;Valyukh, Sergiy;Skarp, Kent
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.202-204
    • /
    • 2004
  • We study theoretically optical properties of thin layered stacked monochrome cholesteric liquid-crystal displays. Thin thickness of the layers (${\sim}1{\mu}m$) allows us appreciably to reduce driving voltage and use such displays in smart cards. Good selective reflection is achieved due to stacked structure. Dependence of the reflectivity of this type of displays on the quantity of the layers, their thickness, and liquid crystal birefringence is investigated.

  • PDF

Bi-Stable and Wide Temperature-Range Electrowetting Displays

  • Blankenbach, K.;Schmoll, A.;Bitman, A.;Bartels, F.;Jerosch, D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1757-1760
    • /
    • 2007
  • Moving a droplet by electrowetting is the basis of our novel displays. This enables mechanical bistable and high reflective monochrome as well as color systems. Since no high temperature process is required, plastic substrates can be used. Our prototypes show promising performance in terms of a wide temperature range, contrast ratio and color.

  • PDF

Automatic measurement of blade width using image processing techniques (영상처리에 의한 연삭면 너비 계측)

  • 김선일;박종구;박찬웅
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.799-804
    • /
    • 1990
  • In the blade grinding process, Blade image is captured. It is captured in the environment with vibration, using monochrome CCD camera with high speed electronic shutter. The image is preprocessed using LoG filter and zero crossing. We used Hough transformation to detect straight lines from the preprocessed image. From the equations of detected lines, we calculated width between lines caused by grinders. This paper proposes automatic measurement of blade width to automate the process control of blade grinding line.

  • PDF

Automatic Blade Measurement for Grinding Process Automation (연마 공정 자동화를 위한 연삭면 자동 계측)

  • Kim, Seon-Il;Park, Jong-Gu;Park, Chan-Ung;Yang, Yun-Mo
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.141-147
    • /
    • 1989
  • Using monochrome CCD camera with high speed electronic shutter. blade image is captured in the environment with vibration. The image is preprocessed using LoG filter and zero crossing. We used Hough transformation method to detect straight lines and obtained width between lines caused by grinders. This paper proposes automatic blade measuring method to automate the process control of blade grinding.

  • PDF

Development of Hydrophilic Performance Measurement System for Anti-Condensation Using Computer Image (컴퓨터 영상을 이용한 오염방지 친수성능 측정 시스템 개발)

  • Ahn, Byung-Tae;Cho, Sung-Ho;Choi, Sun;Kim, Eun-Kuk;Park, Sang-Soo;Hwang, Heon
    • Journal of Biosystems Engineering
    • /
    • v.35 no.4
    • /
    • pp.257-261
    • /
    • 2010
  • Surface energy is the principal factor of anti-condensation. High surface energy appears hydrophilic itself and low surface energy represents hydrophobic itself. The contact angle is widely being used for measurement of surface energy of materials, evaluation of coating performances, measurement of wettability, and so on. However, the existing contact angle measuring system is so expensive for purchasing and complicated, so it takes a lot of time and money to use. This study was conducted to develop the algorithm for evaluating hydrophilic performance through measuring the contact angle of water droplet automatically, and fabricate relatively simple measuring system using a low-cost monochrome camera and image processing. A constant amount of water was firstly allocated on a slide by a micropipette, and then the image of water droplet was captured by monochrome digital camera and sent to a computer. The image was binarized and then reduced noises by labeling. Finally, the contact angle of water droplet was computed by using three points (left, right, and top coordinates), simple linear mathematics, and trigonometric function. The experimental results demonstrated the accuracy and reproducibility of the developed system showing less deviations and deviation ratio.

Effect of LCD monitor type and observer experience on diagnostic performance in soft-copy interpretations of the maxillary sinus on panoramic radiographs

  • Kim, Tae-Young;Choi, Jin-Woo;Lee, Sam-Sun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.41 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • Purpose : The aim of this study was to evaluate the effect of liquid crystal display (LCD) monitor type and observer experience on the diagnostic performance in soft-copy interpretations of maxillary sinus inflammatory lesions on panoramic radiographs. Materials and Methods : Ninety maxillary sinuses on panoramic images were grouped into negative and positive groups according to the presence of inflammatory lesions, using CT for confirmation. Monochrome and color LCDs were used. Six observers participated and ROC analysis was performed to evaluate the diagnostic performance. The reading time, fatigue score, and inter-/intra-observer agreements were assessed. Results : The interpretation of maxillary sinus inflammatory lesions was affected by the LCD monitor type used and by the experience of the observer. The reading time was not significantly different, however the fatigue score was significantly different between two LCD monitors. Inter-observer agreement was relatively good in experienced observers, while the intra-observer agreement for all observers was good with monochrome LCD but not with color LCD. Conclusion : The less experienced observers showed lowered diagnostic ability with a general color LCD.

The compensation of kinematic differences of a robot using image information (화상정보를 이용한 로봇기구학의 오차 보정)

  • Lee, Young-Jin;Lee, Min-Chul;Ahn, Chul-Ki;Son, Kwon;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1840-1843
    • /
    • 1997
  • The task environment of a robot is changing rapidly and task itself becomes complicated due to current industrial trends of multi-product and small lot size production. A convenient user-interfaced off-line programming(OLP) system is being developed in order to overcome the difficulty in teaching a robot task. Using the OLP system, operators can easily teach robot tasks off-line and verify feasibility of the task through simulation of a robot prior to the on-line execution. However, some task errors are inevitable by kinematic differences between the robot model in OLP and the actual robot. Three calibration methods using image information are proposed to compensate the kinematic differences. These methods compose of a relative position vector method, three point compensation method, and base line compensation method. To compensate a kinematic differences the vision system with one monochrome camera is used in the calibration experiment.

  • PDF

Automatic Variable Block Truncation Coding Technique (자동 가변 블록절단 부호화 기법)

  • 김태균;박래홍
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.12
    • /
    • pp.73-86
    • /
    • 1993
  • This paper proposes an automatic variable block truncation coding (BTC) method. It selects the block size automatically based on the mode of the discontinutiy measure of blocks. The combination of an automatic block-size determination scheme and the conventional BTC results in the proposed automatic variable BTC techniques. For color images, subsampling in I and Q chrominance components is adopted along with the variable BTC. To show the effectiveness of the proposed algorithm, its simulation results are compared to those of the several conventional BTC algorithms for monochrome and color test images. Computer simulation shows that the proposed algorithm gives better performance than the conventional ones based on the subjective and objective performance evaluation.

  • PDF

Display Panel for AMOLED with 64 x 64 Pixels on 2' Plastic Substrate

  • Song, Chung-Kun;Ryu, Gi-Seong;Choe, Ki-Beom
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.356-358
    • /
    • 2004
  • In this paper we fabricated and succeeded to demonstrate a test panel for AMOLED on 2" glass and PET substrate. The test panel consisted of an array of 64 x 64 pixels in which OLEDs was driven by pentacene TFT. OTFTs were made of the inverted staggered structure and employed polyvinylphenol as the gate insulator and pentacene thin film as the active layer, producing the filed effect mobility of 0.3$cm^2$/V.sec and on/off current ratio of $10^5$. OLEDs were composed of TPD for HTL and Alq3 for EML with 35nm thick each, generating green monochrome light.

  • PDF