• Title/Summary/Keyword: monitoring module

Search Result 838, Processing Time 0.033 seconds

Throughput Analysis of SBC for MSC on KOMPSAT-2

  • Heo H.P.;Kong J.P.;Kim Y.S.;Park J.E.;Chang Y.J.;Lee S.H.
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.593-596
    • /
    • 2005
  • The MSC is a remote sensing instrument with very high performance that is to be installed on KOMPSAT2 satellite. The MSC consists of EOS (Electro-Optic Subsystem), PMU (Payload Management Unit) and PDTS (Payload Data Transmission Subsystem). PMU controls and monitors all the other payload units by sending commands and collecting telemetry. PMU is in charge of interfacing between payload system and satellite bus system. PMU gets commands from ground-station via OBC (On-Board Computer) that is a main controller of the satellite bus system and sends telemetry to the ground-station via OBC. There is a processor module, called SBC (Single Board Computer) in the PMU. The SBC is a main controller of the MSC system. The main roles of the SBC are payload mission management, command validation and execution, telemetry collection and monitoring, ancillary data handling, event reporting, power control of payload sub-units and communication with these units. Intel's 80486DX2 processor has been used for the SBC. Due to the fact that the SBC plays important roles for imaging mission execution and handles a lot of control data that is required for payload operation, it is required to make analysis of the CPU load when it is in maximum operation mode. In this paper, the analysis and measurement results of the SBC throughput in the maximum operation mode.

  • PDF

QUANTITATIVE MONITORING OF TISSUE OXYGENATION BY TIME-RESOLVED SPECTROSCOPY

  • Yamashita, Yutaka;Oda, Motoki;Ohmae, Etsuko;Tsuchiya, Yutaka
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2101-2101
    • /
    • 2001
  • Near-infrared spectroscopy is now being used in clinical diagnosis as a non-invasive monitor of tissue oxygenation state. However, due to lack of the optical pathlength information within tissues, it is still difficult to quantitate the hemoglobin concentration with present CW techniques. Time-resolved spectroscopy (TRS), which measures temporal profiles of emerging light from tissues, enables to estimate the pathlength distribution within tissues by converting time to distance. Consequently, quantitative measurement of tissue oxygenation is possible by analyzing the data with optical diffusion equation 1) or our Microscopic Beer-Lambert law2). Time-Resolved Spectroscopy System : TRS-1O3) Our TRS-10 system consists of a three-wavelength (759, 797, 833 nm) PLP as pulsed light source, a high speed PMT with high sensitivity and three signal-processing circuits for time-resolved measurement (CFD/TAC, A/D converter and histogram memory). Optical pulse train consisting of 759, 797 and 833nm is generated by PLP at 5㎒ repetition rate and irradiated a sample through a single optical fiber. The diffuse-reflected light from the sample is collected by a bundle fiber and then detected by the PMT for single photon measurement. After being amplified by a following fast amplifier, the electrical signals for each wavelength are picked out by CFD/TAC module. Then, a signal processing circuit integrated the TRS data for each wavelength individually. The simultaneous TRS measurement for three wavelengths achieved without any optical or mechanical switch. Experiment and Results Input and detection fibers of TRS-10 were attached at the human forehead with a fiber separation of 3cm. TRS measurements were continuously performed for about 20 minutes including 2 minutes hyper ventilation. It was observed that the total hemoglobin concentration was decreasing during the hyper ventilation and recovered until 2 minutes after hyper ventilation. On the other hand, the deoxy-hemoglobin concentration began to increase after hyper ventilation and had its peak at around 2 minute later, showing 502 drop from 75% to 60% due to inhibition of breathing by performing hyper ventilation. The results showed that this system might be able to quantitate the concentrations of oxy- and deoxy-hemoglobin in the human brain.

  • PDF

Induction Motor Bearing Damage Detection Using Stator Current Monitoring (고정자전류 모니터링에 의한 유도전동기 베어링고장 검출에 관한 연구)

  • Yoon, Chung-Sup;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.36-45
    • /
    • 2005
  • This paper addresses the application of motor current spectral analysis for the detection of rolling-element bearing damage in induction machines. We set the experimental test bed. They is composed of the normal condition bearing system, the abnormal rolling-element bearing system of 2 type induction motors with shaft deflection system by external force and a hole drilled through the outer race of the shaft end bearing of the four pole test motor. We have developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module is checking stator current The effects on the stator current spectrum are described and related frequencies are also determined. This is an important result in the formulation of a fault detection scheme that monitors the stator currents. We utilized the FFT(Fast Fourier Transform), Wavelet analysis and averaging signal pattern by inner product tool to analyze stator current components. Especially, the analyzed results by inner product clearly illustrate that the stator signature analysis can be used to identify the presence of a bearing fault.

Development of Power Supplies for Radiation Monitoring System and Process Control System of Korean-type Standard Nuclear Pourer Plants (한국형 표준원전의 방사선감시계통 및 공정제어계통 전원공급기 국산화 개발)

  • Roh, J.H.;Kwon, Y.G.;Jang, D.S.;Oh, C.Y.;Lee, C.H.;Kim, Y.K.;Ju, D.S.;Cho, H.M.;Park, W.G.
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.515-517
    • /
    • 2008
  • 현재 가동 중인 원자적발전소 계측제어설비의 전원공급기를 살펴보면 인버터 또는 별도의 교류를 입력전원으로 사용한다. 직류 전원공급기들은 설비의 중요도예 따라 이중화로 구성된 설비도 있고 그렇지 않은 기기나 설비도 있다. 이중화로 구성된 전원공급기라 해도 교류 입력전원이 동일하다면 교류 입력이 상실될 때 이중화로 구성된 직류전원도 상실되어 관련계통의 가동이 정지된다. 이러한 문제점을 해결하기 위해서는 각기 다른 교류입력전원으로 동작되는 이중화전원공급기로 구성되는 것이 가장 바람직하다. 본 연구개발의 목적은 두 종의 설비에 소요되는 3종의 직류전원 공급기를 원자력 안정성등급으로 국산화하는 연구이다. 기존 제품들은 3종 모두 리니어 방식의 제품이지만, 방사선감시 계통 현장제어기의 5V로직 전원공급기와 공정제어계통 전원공급자는 전력변환효율이 높고 소형, 정량화가 가능한 SMPS(Switched Mode Power Supply) 방식으로 개발하였다. 방사선감시계통 현장제어기의 PCA(Printed Circuit Assembly) 저전압공급기는 다양한 종류의 출력전압과 저 전류형이므로 안정성 면에서 동일한 형식의 리니어 방식으로 개발하였으며 3종류 모두 출력용량을 20% 이상 향상시켰다. 또한, 논문을 통해 SMPS 방식의 전원공급기의 핵심 부품인 Control Module을 Hybrid IC형으로 자체 설계하여 성능이 우수한 제품을 지속적으로 생산할 수 있는 기틀을 마련하고자 한다.

  • PDF

QEMU/KVM Based In-Memory Block Cache Module for Virtualization Environment (가상화 환경을 위한 QEMU/KVM 기반의 인메모리 블록 캐시 모듈 구현)

  • Kim, TaeHoon;Song, KwangHyeok;No, JaeChun;Park, SungSoon
    • Journal of KIISE
    • /
    • v.44 no.10
    • /
    • pp.1005-1018
    • /
    • 2017
  • Recently, virtualization has become an essential component of cloud computing due to its various strengths, including maximizing server resource utilization, easy-to-maintain software, and enhanced data protection. However, since virtualization allows sharing physical resources among the VMs, the system performance can be deteriorated due to device contentions. In this paper, we first investigate the I/O overhead based on the number of VMs on the same server platform and analyze the block I/O process of the KVM hypervisor. We also propose an in-memory block cache mechanism, called QBic, to overcome I/O virtualization latency. QBic is capable of monitoring the block I/O process of the hypervisor and stores the data with a high access frequency in the cache. As a result, QBic provides a fast response for VMs and reduces the I/O contention to physical devices. Finally, we present a performance measurement of QBic to verify its effectiveness.

Research on the technical development by the CAD/CAM System (CAD/CAM시스템을 이용한 기술개발에 대한 연구 (워엄기어 개발을 중심으로))

  • Jeong, Seon-Mo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.3 no.3
    • /
    • pp.40-71
    • /
    • 1986
  • By developing a computer program for the systematic design of worm gears, the design formulae and tables of AGMA, JGMA, BS and DIN are analized and compared. The computer program can be used on micro-computers. According to the input data of the reduction ratio, the center distance. the driving torque and the material as design parameters, the program calculate the most efficient worm gear dimension. The variation of the design parameters and other empirical coefficients in case of resulting an inadequate design gear dimension can be easily modified throuth the way of interactive method between the user and the monitoring system of computer. A proposal of the standardization of worm gears was made in which a standard module according to the DIN 323 standard series number was applied. For the more exact and effective calculation of the stress concentration and the deformation of gear teeth, a computer program using the boundary element method is also developed. Even the strength of the special gear shape such as Niemann's "Cavex" gear can be calculated in a short CPU-time. The most effort of this study has been layed on the developing a computer program for the correction of a tooth profile and face width which is most important design factor for an exact and wide teeth contacts under loads, especially by great and wide gears. For this purpose were investigated the tooth stiffness, the mesh interferences and the kinematics and the dynamics of gear mesh. The deflection and the deformation of the gear shaft due to the loads acting on gear and shaft were aslo considered. Some examples have shown the sufficient good status of teeth contact in which the correction of the tooth profile and face width were accomplished due to the calculated results.d results.

  • PDF

Development and Estimation of a Wireless Controlled Implantable Electric-stimulator for the Blood Pressure Regulation (혈압조절을 위한 모선 제어되는 체내 이식형 전기 자극기의 개발 및 체외 성능 평가)

  • Kim, Yoo-Seok;Park, Seong-Min;Shim, Eun-Bo;Choi, Seong-Wook
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.395-400
    • /
    • 2010
  • Hypertension is the chronic disease that the 16% of total population are suffering, and it needs to be studied to find alternative treatment because of the tolerance and side effect of medications that may bother some patients. in this paper, we verified practicality of implantable electrical stimulator that can readily change stimulus magnitude and frequency. And this device is possible to stimulate baroreflex or parasympathetic nerve. Therefore we performed in vitro tests and animal experiment for device's operating conditions. This device consist of implantable electrical stimulator and extracorporeal control/monitoring system. Stimulator was designed to make 1Hz~100Hz pulses and it can change continuous or periodic pulse train type. And this device can control stimulator's function and monitor stimulator's status and patients' blood pressure at exterior of body using ZigBee module as wireless telecommunication. We verified that stimulator have error rate under 5% at 50mm depth of organs and, stimulator makes high-efficiency energy with closer position of two electrodes. Also we can confirm the performance of device that decreasing blood pressure and heart rate of a rat by electrical stimulation.

Implementation of Movement Detection System for Patient on Bed (병상환자의 움직임 감지 시스템 구현)

  • Baec, Sung-Ho;Jeon, Min-Sik;Ko, Bong-Jin
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.458-463
    • /
    • 2015
  • This paper suggests detection system for the movement of patient on bed based on IEEE802.15.4 by using pressure pad and guard sensor. The system is designed to detect ordinary activities of patients on bed as well as patients' falling from the bed while sleeping at night. The node that is installed at bed sends data to gather when the pressure pad and sensor of guard detect patients' activities and falling. These data sent to gather are transmitted to monitor at help desk by TCP/IP communication. To remove unnecessary data that occurred due to switch chattering during tossing and turning, timer of MCU is used. Also, Communication module can change transmission power to apply this system to various environments of hospital room. Therefore, the nurse can take care of patients on bed in real time with data about patients' conditions.

Development of a Wireless Gamma-ray Probe for Diagnosing and Evaluation of its Effectiveness (진단용 무선 감마선 프로브 개발 및 유용성 평가)

  • Park, Hyemin;Joo, Koansik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.173-181
    • /
    • 2015
  • We developed a wireless gamma-ray probe based on radiation photon counting method to diagnose and detect remaining lesions after surgery, and its effectiveness was evaluated using calibration sources and a phantom. The probe was designed and miniaturized using a semi-conductor-based radiation sensor, and a Bluetooth remote communication module was used to implement the wireless diagnosis and detection system. Moreover, a remote monitoring system was implemented to monitor affected areas during diagnosis and surgery. To assess the effectiveness of the developed probe in this study, calibration sources $^{57}Co$, $^{133}Ba$, $^{22}Na$ and $^{137}Cs$ and a chicken breast phantom were used. Furthermore, the probe's detection response to gamma ray was confirmed through evaluation. Its clinical applicability was verified by assessing the response linearity and detection direction according to gamma-ray intensity, as well as the detection efficiency according to the depth of the gamma source in the phantom.

Preliminary Study for Estimation of Nonlinear Constitutive Laws by using Back Analysis and Field Measurement (역해석 수법과 현장계측에 의한 비선형 구성법칙 결정에 관한 기초적인 연구)

  • Lee, Jae-Ho;Akutagawa, Shinichi;Kim, Young-Su;Sakurai, Shunsuke;Jin, Guang-Ri;Kim, Nag-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1278-1289
    • /
    • 2008
  • Currently in increasing number of urban tunnels with small overburden are excavated according to the principle of the New Austrian Tunneling Method (NATM). Successful design, construction and maintenance of NATM tunnel in urban area demands prediction, control and monitoring of surface settlement, gradient and ground displacement with high accuracy. Use of measured displacement for parameter determination has been researched over the years, and one geotechnical engineering principle has been formed as back analysis. In this paper, back analysis of a ground deformational behavior involving nonlinear behavior is discussed. It is of primary importance to make reliable prediction of deformational behavior for shallow tunnels in soft ground. However, predictions made often prove to be incorrect due to complexity of constitutive law and other relevant factors. Back analysis therefore becomes more important, for it may be used to interpret measured displacement to derive nonlinear material characteristics. The paper shows some example in which a deformational mechanism is studied in the light of inhomogeneous distrubution of Young's module, from which a logic is derived to identify two different types of nonlinear constitutive relationships.

  • PDF