• 제목/요약/키워드: moment-resisting frame

검색결과 268건 처리시간 0.026초

Effect of column loss location on structural response of a generic steel moment resisting frame

  • Rezvani, Farshad Hashemi;Jeffers, Ann E.;Asgarian, Behrouz;Ronagh, Hamid Reza
    • Steel and Composite Structures
    • /
    • 제25권2호
    • /
    • pp.217-229
    • /
    • 2017
  • The effect of column loss location on the structural response of steel moment resisting frames (MRF) is investigated in this study. A series of nonlinear static and dynamic analyses were performed to determine the resistance of a generic frame to an arbitrary column loss and detect the structural members that are susceptible to failure progression beyond that point. Both force-controlled and deformation-controlled actions based on UFC 4-023-03 and ASCE/SEI 41-06 were implemented to define the acceptance criteria for nine APM cases defined in this study. Results revealed that the structural resistance against an arbitrary column loss in the top story is at least 80% smaller than that of the bottom story. In addition, it was found that the dynamic increase factor (DIF) at the failure point is at most 1.13.

조합하중시의 플랫 플레이트 슬래브 시스템에 대한 수정된 등가골조 모델 (A Modified Equivalent Frame Model for Flat Plate Slabs Under Combined Lateral and Gravity Loads)

  • 오승용;박영미;한상환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.369-372
    • /
    • 2006
  • Flat plate slab systems have been commonly used as a gravity force resisting systems, which should be constructed with lateral force resisting systems such as shear walls and moment resisting frame. ACI 318(2005) allows the Direct design method, the equivalent frame method (ACI-EFM) under gravity loads and the finite-element models, effective beam width models and equivalent frame models under lateral loads. ACI-EFM can be used for gravity loads as well as lateral loads analysis. But the method may not predict the behavior of flat plate slabs under lateral loads. Thus Previous study developed a Modified equivalent frame method(Modified-EFM) which could give more precise answer for flat plate slab under lateral loads. This study is to verified the accuracy of a Modified-EFM under combined lateral and gravity loads. The accuracy of this model is verified by comparing the results using the Modified-EFM with the results of finite element analysis. For this purpose, 7 story building is considered. The analysis results of other existing models are included. The analysis results show that Modified-EFM produces comparable drift and slab internal moments with those obtained from finite element analysis.

  • PDF

Knee brace가 설치된 모멘트저항골조의 내진성능 (Seismic Performance of a Knee-Braced Moment Resisting Frame)

  • 최현훈;김진구
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.171-180
    • /
    • 2005
  • 본 연구에서는 기름이나 가스의 송유관을 지지하기 위하여 일반적으로 사용되는 3층의 Knee brace가 설치된 모멘트저항골조(KBMRF)의 내진성능을 평가하였다. KBMRF의 하중-변위 관계를 관찰하기 위하여 비선형 정적 pushover 해석을 수행하였다. 최대층간변위가 층높이의 1.5%에 도달하였을 때 보와 기둥과 같은 주요 구조부재는 탄성상태를 유지하는 것으로 나타났다. UBC-97의 설계스펙트럼에 부합되도록 조정한 8개의 지진기록을 이용하여 비선형 동적시간이력해석을 수행한 결과에 따르면, 최대층간변위는 구조물 높이의 1.5% 변위한계보다 작았고 기둥은 탄성적으로 거동하였다. 따라서 본 연구에서 고려한 KBMRF 구조물의 내진성능은 내진설계기준에서 규정한 모든 요구사항을 만족하는 것으로 나타났다.

리브로 보강된 기둥-보 접합부의 내진성능 평가 (Seismic Performance of Rib Plate H Beam to Column Connections)

  • 김성용;신창훈
    • 한국방재학회 논문집
    • /
    • 제6권1호
    • /
    • pp.9-16
    • /
    • 2006
  • 모멘트 저항골조는 내진성능이 매우 우수한 것으로 알려져 왔으며 많은 건축물의 설계에 이용되며 시공되어지고 있으나 노스리지 지진과 고베 지진시 충분한 내진성능을 발휘하지 못하고 접합부에서 균열 또는 취성파괴가 발생하였다. 양지진 이후 접합부의 내진성능을 향상시키고자 접합부 상세에 대한 연구가 활발히 진행되고 있으며, 우리나라에서도 지진에 대한 사회적 관심과 일본에서 발생한 지진이 한반도에 영향을 주는 상황에서, 이에 대한 사회전반의 관심과 우려가 제기되고 있다. 본 논문에서는 H형 보 웨브의 고장력볼트 전단접합과 H형 플랜지의 리브보강 유무를 변수로 한 실대형 실험체를 가지고 실험을 실시하였다. 실험을 통해 보 웨브의 2면 전단접합을 통해 고장력 볼트수 감소와 시공성 향상을 기대하며, 리브플레이트 보강을 통해 내진성능을 향상시키고자 한다. 또한 논 스켈럽을 통해 응력집중에 의한 취성파괴를 방지하고자 한다.

Experimental and numerical assessment of beam-column connection in steel moment-resisting frames with built-up double-I column

  • Dehghan, Seyed Mehdi;Najafgholipour, Mohammad Amir;Ziarati, Seyed Mohsen;Mehrpour, Mohammad Reza
    • Steel and Composite Structures
    • /
    • 제26권3호
    • /
    • pp.315-328
    • /
    • 2018
  • Built-up Double-I (BD-I) columns consist of two hot rolled IPE sections and two cover plates which are welded by fillet welds. In Iran, this type of column is commonly used in braced frames with simple connections and sometimes in low-rise Moment Resisting Frames (MRF) with Welded Flange Plate (WFP) beam-column detailing. To evaluate the seismic performance of WFP connection of I-beam to BD-I column, traditional and modified exterior MRF connections were tested subjected to cyclic prescribed loading of AISC. Test results indicate that the traditional connection does not achieve the intended behavior while the modified connection can moderately meet the requirements of MRF connection. The numerical models of the connections were developed in ABAQUS finite element software and validated with the test results. For this purpose, moment-rotation curves and failure modes of the tested connections were compared with the simulation results. Moreover to avoid improper failure modes, some improvements of the connections were evaluated through a numerical study.

The practice of blind bolting connections to structural hollow sections: A review

  • Barnett, T.C.;Tizani, W.;Nethercot, D.A.
    • Steel and Composite Structures
    • /
    • 제1권1호
    • /
    • pp.1-16
    • /
    • 2001
  • Due to aesthetic, economic, and structural performance, the use of structural hollow sections as columns in both continuous moment resisting and nominally pinned construction is attractive. Connecting the beams to these sections is somewhat problematic as there is no access to the interior of the section to allow for the tightening of a standard bolt. Therefore, bolts that may be tightened from one side, i.e., blind bolts, have been developed to facilitate the use of site bolting for this arrangement. This paper critically reviews available information concerning blind bolting technology, especially the performance of fasteners in shear, tension, and moment resisting connections. Also provided is an explanation of the way in which the results have been incorporated into design guidance covering the particular case of nominally pinned connections. For moment resisting connections, it is concluded that whilst the principle has been adequately demonstrated, sufficient data are currently not available to permit the provision of authoritative design guidance. In addition, inherent flexibilities in the connections mean that performance equivalent to full strength and rigid is unlikely to be achievable: a semicontinuous approach to frame design will therefore be necessary.

Seismic performance of concrete moment resisting frame buildings in Canada

  • Kafrawy, Omar El;Bagchi, Ashutosh;Humar, Jag
    • Structural Engineering and Mechanics
    • /
    • 제37권2호
    • /
    • pp.233-251
    • /
    • 2011
  • The seismic provisions of the current edition (2005) of the National Building Code of Canada (NBCC) differ significantly from the earlier edition. The current seismic provisions are based on the uniform hazard spectra corresponding to 2% probability of exceedance in 50 years, as opposed to the seismic hazard level with 10% probablity of exeedance in 50 years used in the earlier edition. Moreover, the current code is presented in an objective-based format where the design is performed based on an acceptable solution. In the light of these changes, an assessment of the expected performance of the buildings designed according to the requirements of the current edition of NBCC would be very useful. In this paper, the seismic performance of a set of six, twelve, and eighteen story buildings of regular geometry and with concrete moment resisting frames, designed for Vancouver western Canada, has been evaluated. Although the effects of non-structural elements are not considered in the design, the non-structural elements connected to the lateral load resisting systems affect the seismic performance of a building. To simulate the non-structural elements, infill panels are included in some frame models. Spectrum compatible artificial ground motion records and scaled actual accelerograms have been used for evaluating the dynamic response. The performance has been evaluated for each building under various levels of seismic hazard with different probabilities of exceedance. From the study it has been observed that, although all the buildings achieved the life-safety performance as assumed in the design provisions of the building code, their performance characteristics are found to be non-uniform.

선형해석방법을 이용한 철골 모멘트골조의 붕괴저항성능 (Collapse-Resisting Capacity of Steel Moment Frames Using the Linear Elastic Analysis)

  • 김진구;양정호;김태완
    • 한국전산구조공학회논문집
    • /
    • 제20권4호
    • /
    • pp.435-442
    • /
    • 2007
  • 1968년 영국의 Ronan Point 아파트에서 발생한 연쇄붕괴 이후 이에 대한 연구가 간헐적으로 진행되어 왔으며, 최근 미국의 World Trade Center 붕괴 후 연쇄붕괴에 대한 연구가 다시 활발히 진행되고 있다. 미국에서는 기존의 연구결과를 바탕으로 2003년 GSA 및 2005년 DoD에서 연쇄붕괴에 대한 설계 및 해석 지침을 제시하였다. 본 연구에서는 이러한 지침서에서 제시하고 있는 선형정적해석법과, 선형동적해석법을 사용하여 국내 설계기준에 의해 설계된 철골 모멘트저항골조에 대한 붕괴저항 성능을 조사하였다. 해석결과에 따르면 GSA 기준을 적용할 경우 횡력을 고려하지 않은 수직저항시스템은 연쇄 붕괴에 취약한 것으로 나타났으나, 지진력을 고려하여 설계된 수평저항시스템은 연쇄붕괴에 대해 안전한 결과를 얻었다. 하지만 DoD 기준에 따르면 두 시스템 모두 연쇄붕괴에 취약한 것으로 나타났다.

Novel pin jointed moment connection for cold-formed steel trusses

  • Mathison, Chris;Roy, Krishanu;Clifton, G. Charles;Ahmadi, Amin;Masood, Rehan;Lim, James B.P.
    • Steel and Composite Structures
    • /
    • 제31권5호
    • /
    • pp.453-467
    • /
    • 2019
  • Portal frame structures, made up of cold-formed steel trusses, are increasingly being used for lightweight building construction. A novel pin-jointed moment connector, called the Howick Rivet Connector (HRC), was developed and tested previously in T-joints and truss assemblage to determine its reliable strength, stiffness and moment resisting capacity. This paper presents an experimental study on the HRC, in moment resisting cold-formed steel trusses. The connection method is devised where intersecting truss members are confined by a gusset connected by HRCs to create a rigid moment connection. In total, three large scale experiments were conducted to determine the elastic capacity and cyclic behaviour of the gusseted truss moment connection comprising HRC connectors. Theoretical failure loads were also calculated and compared against the experimental failure loads. Results show that the HRCs work effectively at carrying high shear loads between the members of the truss, enabling rigid behaviour to be developed and giving elastic behaviour without tilting up to a defined yield point. An extended gusset connection has been proposed to maximize the moment carrying capacity in a truss knee connection using the HRCs, in which they are aligned around the perimeter of the gusset to maximize the moment capacity and to increase the stability of the truss knee joint.

비선형동적해석을 통한 국내 철골 모멘트골조의 내진성능 평가 (Seismic Performance Evaluation of Steel Moment Frames in Korea Using Nonlinear Dynamic Analysis)

  • 김태완
    • 한국지진공학회논문집
    • /
    • 제16권4호
    • /
    • pp.1-8
    • /
    • 2012
  • 국내 철골모멘트골조를 이전 KBC2005 및 현 KBC2009 기준에 따라 설계한 후 비선형동적해석을 이용하여 FEMA355F의 내진성능평가 절차에 따라 성능을 평가하였다. 그 결과 비선형정적 Push-over 해석을 이용한 역량스펙트럼법과 차이가 있었다. 특히 국내 철골모멘트골조는 약패널존을 가지기 때문에 비선형동적해석을 통해서만 보다 정확한 거동을 예측할 수 있었다. 국내 철골모멘트골조는 지반 조건 SB 또는 SC에 위치한다면 층수 및 R값에 관계없이 성능목표를 만족하는 것으로 나타났다. 하지만 지반 조건 SD 또는 SE에 위치한다면 성능목표 만족 여부는 명확하지 않았다. 따라서 KBC2005나 KBC2009 어떤 기준을 사용하더라도 지반 조건이 상대적으로 좋다면 국내 철골모멘트골조는 내진성능을 충분히 확보하고 있다고 볼 수 있다.