• Title/Summary/Keyword: moment matrix

Search Result 209, Processing Time 0.022 seconds

Effects of neutron irradiation on superconducting critical temperatures of in situ processed MgB2 superconductors

  • Kim, C.J.;Park, S.D.;Jun, B.H.;Kim, B.G.;Choo, K.N.;Ri, H.C.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.9-13
    • /
    • 2014
  • Effects of neutron irradiation on the superconducting properties of the undoped $MgB_2$ and the carbon(C)-doped $MgB_2$ bulk superconductors, prepared by an in situ reaction process using Mg and B powder, were investigated. The prepared $MgB_2$ samples were neutron-irradiated at the neutron fluence of $10^{16}-10^{18}n/cm^2$ in a Hanaro nuclear reactor of KAERI involving both fast and thermal neutron. The magnetic moment-temperature (M-T) and magnetization-magnetic field (M-H) curves before/after irradiation were obtained using magnetic property measurement system (MPMS). The superconducting critical temperature ($T_c$) and transition width were estimated from the M-T curves and critical current density ($J_c$) was estimated from the M-H curves using a Bean's critical model. The $T_cs$ of the undoped $MgB_2$ and C-doped $MgB_2$ before irradiation were 36.9-37.0 K and 36.6-36.8 K, respectively. The $T_cs$ decreased to 33.2 K and 31.6 K, respectively after irradiation at neutron fluence of $7.16{\times}10^{17}n/cm^2$, and decreased to 22.6 K and 24.0 K, respectively, at $3.13{\times}10^{18}n/cm^2$. The $J_c$ cross-over was observed at the high magnetic field of 5.2 T for the undoped $MgB_2$ irradiated at $7.16{\times}10^{17}n/cm^2$. The $T_c$ and $J_c$ variation after the neutron irradiation at various neutron fluences were explained in terms of the defect formation in the superconducting matrix by neutron irradiation.

Probabilistic Behavior of In-plane Structure due to Multiple Correlated Uncertain Material Constants (상호 상관관계가 있는 다중 재료상수의 불확실성에 의한 평면구조의 확률론적 거동)

  • Noh Hyuk-Chun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.18 no.3
    • /
    • pp.291-302
    • /
    • 2005
  • Due to the importance of the parameter in structural response, the uncertain elastic modulus was located at the center of stochastic analysis, where the response variability caused by the uncertain system parameters is pursued. However when we analyze the so-called stochastic systems, as many parameters as possible must be included in the analysis if we want to obtain the response variability that can reach a true one, even in an approximate sense. In this paper, a formulation to determine the statistical behavior of in-plane structures due to multiple uncertain material parameters, i.e., elastic modulus and Poisson's ratio, is suggested. To this end, the polynomial expansion on the coefficients of constitutive matrix is employed. In constructing the modified auto-and cross-correlation functions, use is made of the general equation for n-th moment. For the computational purpose, the infinite series of stochastic sub-stiffness matrices is truncated preserving required accuracy. To demons4rate the validity of the proposed formulation, an exemplary example is analyzed and the results are compared with those obtained by means of classical Monte Carlo simulation, which is based on the local averaging scheme.

A Filtered-x Affine Projection Sign Algorithm with Improved Convergence Rate for Active Impulsive Noise Control (능동 충격성 소음 제어를 위한 향상된 수렴 속도를 가지는 Filtered-x 인접 투사 부호 알고리즘)

  • Lee, En Jong;Kim, Jeong Rae;Chung, Ik Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.130-137
    • /
    • 2015
  • In this paper, we propose a new Modified Filtered-x Affine Projection Sign Algorithm(MFxAPSA) to improve the convergence speed of the conventional MFxAPSA which has been proposed for active control of impulsive noise. Under the impulsive noise environment, the adaptive algorithms based on the second order moment such as the Filtered-x Least Mean Square(FxLMS) show slow convergence speed or diverge because the noise source tends to have infinite variance. The MFxAPSA is the algorithm derived by applying the Affine Projection Sign Algorithm(APSA) to active noise control. The APSA has an advantage that it does not need the calculation for the inverse matrix, so it may be suitable for the active noise control that requires low computational burden. The proposed MFxAPSA also has APSA's advantage and furthermore, better performance than the conventional MFxAPSA. We carried out a performance comparison of the proposed MFxAPSA with the conventional MFxAPSA. It is shown that the proposed MFxAPSA has the faster convergence speed than the conventional MFxAPSA.

A Rotating Balance Design and Performance Estimation for a Rotor Test Jig (로터 실험 장치용 Rotating Balance의 설계 및 성능 검증에 관한 연구)

  • Ryi, Jae-Ha;Rhee, Wook;Choi, Jong-Soo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.301-306
    • /
    • 2009
  • In this study a 3-component rotating balance, which is designed to measure the thrust (Fz) and two moment components (Mx, My) simultaneously for a rotor test jig, is designed and its performance is validated experimentally. The low voltage signal from the strain gages mounted on the balance is amplified with a rotating amplifier, which is then fed through a slip-ring unit into the data acquisition system. In order to validate the accuracy of the calibration matrix obtained from a static calibration test, an additional reaction type balance is used to measure the thrust from a model rotor simultaneously, and shows very good result. Finally, the expanded uncertainty value, which is obtained from ISO method is estimated to be $2.82\times10^{-1}$, and the balance turns out to be reliable.

An Analysis of the Springing Phenomenon of a Ship Advancing in Waves (파랑 중에 전진하는 선박에 대한 스프링잉 현상 해석)

  • H.Y. Lee;H. Shin;H.S. Park;J.H. Park
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.38 no.3
    • /
    • pp.41-46
    • /
    • 2001
  • The very large vessels like VLCC and container ship have been built recently and those vessels have smaller structural strength in comparison with the other convectional skips. As a result the fatigue destruction of upper deck occurs a frequently due to the springing phenomenon at the encountering frequencies. In this study, the hydrodynamic loads are calculated by three-dimensional source distribution method with the translating and pulsating Green function. A ship is longitudinally divided into 23 sections and the added mass, damping and hydrodynamic force of each section is calculated. focusing only on the vertical motion. Stiffness matrix is calculated by the Euler beam theory. The calculation is carried out for Esso Osaka.

  • PDF

Nonlinear Dynamic Analysis of Steel Lazy Wave Riser using Lumped Mass Line Model (집중질량 라인모델을 이용한 Steel Lazy Wave Riser의 비선형 동적 해석)

  • Oh, Seunghoon;Jung, Jae-Hwan;Park, Byeongwon;Kwon, Yong-Ju;Jung, Dongho
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.400-410
    • /
    • 2019
  • In this study, the numerical code for the 3D nonlinear dynamic analysis of an SLWR (Steel Lazy Wave Riser) was developed using the lumped mass line model in a FORTRAN environment. Because the lumped mass line model is an explicit method, there is no matrix operation. Thus, the numerical algorithm is simple and fast. In the lumped mass line model, the equations of motion for the riser were derived by applying the various forces acting on each node of the line. The applied forces at the node of the riser consisted of the tension, shear force due to the bending moment, gravitational force, buoyancy force, riser/ground contact force, and hydrodynamic force based on the Morison equation. Time integration was carried out using a Runge-Kutta fourth-order method, which is known to be stable and accurate. To validate the accuracy of the developed numerical code, simulations using the commercial software OrcaFlex were carried out simultaneously and compared with the results of the developed numerical code. To understand the nonlinear dynamic characteristics of an SLWR, dynamic simulations of SLWRs excited at the hang-off point and of SLWRs in regular waves were carried out. From the results of these dynamic simulations, the displacements at the maximum bending moments at important points of the design, like the hang-off point, sagging point, hogging points, and touch-down point, were observed and analyzed.

Flow Effects on Tailored RF Gradient Echo (TRFGE) Magnetic Resonance Imaging : In-flow and In-Plane Flow Effect (Tailored RF 경자사계방향 (TRFGE} 자기공명영상(MRI)에서 유체에 의한 영상신호 변화 : 유체유입효과와 영상면내를 흐르는 유체의 효과에 대하여)

  • Mun, Chi-Ung;Kim, Sang-Tae;No, Yong-Man;Im, Tae-Hwan;Jo, Jang-Hui
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.243-251
    • /
    • 1997
  • In this paper, we have reported two interesting flow effects arising in the TRFGE sequence using water flow phantom. First, we have shown that the TRFGE sequence is indeed not affected by "in-flow" effect from the unsaturated spins flowing into the imaging slice. Second, the enhancement of "in-plane flow" signal in the readout gradient direction was observed when the TRFGE sequence was used without flow compensation. These two results have many interesting applications in MR imaging other than fMRI. Results obtained were also compared with the results obtained by the conventional gradient echo(CGE) imaging. Experiments were performed at 4.7T MRI/S animal system (Biospec, BRUKER, Switzerland). A cylindrical phantom was made using acryl and a vinyl tube was inserted at the center(Fig. 1). The whole cylinder was filled with water doped with $MnCl_2$ and the center tube was filled with saline which flows in parallel to the main magnetic field along the tube. Tailored RF pulse was designed to have quadratic ($z^2$) phase distribution in slice direction(z). Imaging parameters were TR/TE = 55~85/10msec, flip angle = $30^{\circ}$, slice thickness = 2mm, matrix size = 256${\times}$256, and FOV= 10cm. In-flow effect : Axial images were obtained with and without flow using the CGE and TRFGE sequences, respectively. The flow direction was perpendicular to the image slice. In-plane flow : Sagittal images were obtained with and without flow using the TRGE sequence. The readout gradient was applied in parallel to the flow direction. We have observed that the "in-flow" effect did not affect the TRFGE image, while "in-plane flow" running along the readout gradient direction enhanced the signal in the TRFGE sequence when flow compensation gradient scheme was not used.

  • PDF

The Importance and Performance Analysis of Service Encounter Quality by Types of Restaurants (레스토랑 유형별 서비스 인카운터 품질의 중요도 및 수행도 분석)

  • Jo, Mi-Na
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.8
    • /
    • pp.1076-1087
    • /
    • 2006
  • The purpose of this study was to identify critical control points of service encounter by types of restaurants in order to manage moment of truth when customers encounter services. Questionnaires were collected from 812 customers (aged 15 years or older) who had used restaurants in Seoul, from October 24, 2005 to November 6, 2005. The main results of this study were as follows: Statistically significant differences were shown between importance and performance of interaction quality, physical environment quality and outcome quality. Significant differences were also shown in importance and performance of interaction and physical environment quality, and performance of outcome quality by restaurant types but no significant difference was indicated in importance of outcome quality by restaurant types. That is, the importance of outcome quality, which means the quality of food, was regarded as important by customers who use restaurants regardless of types of restaurants. The result of examining interaction quality showed that family restaurants managed waiting customers quite well and provided information on the Internet homepage. Performance of responding to customers with complaints was rated the highest in family restaurants. Regarding physical environment quality, importance and performance scores significantly differed by types of restaurants in order of fine-dining restaurants, family restaurants, and fast-food restaurants. In terms of service encounter quality, items whose importance scores were high but performance scores were low in importance-performance analysis matrix were 'quality of provided food is always uniform' and 'the space between other tables is enough' for fine-dining restaurants. In family restaurants, 'size of chairs or tables is enough', and 'the space between other tables is enough' were included in the items, while 'interior facilities are attractive', 'size of chairs and tables is enough', and 'the space between other tables is enough' were included in the items in case of fast-food restaurants. A difference was indicated depending on types of restaurants.

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.