• Title/Summary/Keyword: molar volume

Search Result 165, Processing Time 0.026 seconds

Studies of Refractive Index and Hardness In Quarternary NaBAISi Glasses (4성분 NaBAISi 유리계의 굴절률과 경도 연구)

  • Moon, Seong-Jun;Hwang, In-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2003
  • Quarternary $Na_2O-B_2O_3-Al_2O_3-SiO_2$ glasses were fabricated by the function of $R({\equiv}Na_2O\;mole%/B_2O_3\;mole%)$ and $K({\equiv}(Al_2O_3\;mole%+SiO_2\;mole%)/B_2O_3mole%)$. The structures of these glasses were investigated through refractive index and vicker's hardness. The refractive index increased as the increase of the polarizability in the glass network. In the region of low $Na_2O$ content, the refractive index increased due to the increase of the polarizability in the glass network, but in the region of high $Na_2O$ content, the rate of increase of the refractive index decreased due to the increase of the molar volume caused by the formation of $BO_3{^-}$ units with relatively high molar volume. And, the refractive index decreased as the increase of $Al_2O_3+SiO_2$ content with the molar volume in the glass network. The increase and decrease of vicker's hardness values for those glasses depended on the fraction of tetrahedral $BO_4$ units and it of triangle $BO_3{^-}$ units with non-bridging oxygen, respectively.

  • PDF

Excimer Fluorescence Quenching of Poly (styrene-co-acrylic acid)-Eu Complex by Simple Hydrocarbons in Tetrahydrofuran Solutions

  • Park, Doo-Hee;Kim, Kang-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.7 no.1
    • /
    • pp.42-45
    • /
    • 1986
  • Quenching of excimer fluorescence from polystyrene-acrylic acid copolymers containing $Eu^{3+}$ has been studied in tetrahydrofuran solution using simple aromatic hydrocarbons as quenchers under steady-state conditions. Aromatic hydrocarbons quenched collisionally the excimer fluorescence and their rate constants of quenching were determined. The magnitude of quenching constant is interpreted in terms of the cube root of the molar volume of quencher. Cycloalkanes were not effective in quenching the excimer fluorescence possibly due to different solubility characteristics from aromatic hydrocarbons.

Theory of Liquid Water (액체 물에 관한 이론)

  • Pak Hyungsuk
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.460-468
    • /
    • 1976
  • A theory of liquid water is developed by assuming that the molecules in the liquid state have solid-like and gas-like degrees of freedom. The spectroscopic data are used in assigning the vibrational frequencies of solid-like molecules. The calculated values of molar volume, vapor pressure, entropy, entropy of vaporization, expansion coefficient, compressibility, heat capacities at constant volume and at constant pressure, surface tension and critical point properties are all in excellent agreement with the observed data.

  • PDF

The Calculation of Physical Properties of Amino Acids using Molecular Modeling Techniques

  • Ui-Rak Kim;Kyung-Sub Min;Bong-Jin Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.2
    • /
    • pp.106-112
    • /
    • 1994
  • Six physical properties (molecular weight, heat capacity, side chain weight, side chain volume, standard entropy and partial molar volume) of amino acids, peptides and their derivatives were examined by molecular modeling techniques. The molecular connectivity index, Wiener distance index and ad hoc descriptor are employed as structural parameters to encode information about branching, size, cyclization, unsaturation, heteroatom content and polarizability. This paper examines the correlation of the molecular modeling techique's parameters and the physicochemical properties of amino acids and their derivatives. As a result, calculated values were in agreement with experimental data in the above six physical properties of amino acids, peptides and their derivatives and the molecular connectivity index was superior to the other indices in fitting the calculated data.

The Pressure Effect on the Ionization of m-Chloroanilinium Ion in Sodiumacetate Buffer Solution

  • Jee ,Jong-Gi;Lee, Young-Hwa;Kwak, Young-Jik
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.5
    • /
    • pp.266-269
    • /
    • 1985
  • The dissociation constants(K) of m-chloroanilinium ion in water-ethanol mixture, where the volume percentage of water is 89.5%, were evaluated by UV-spectroscopic method at $20{\sim}50^{\circ}C$, up to 1500 bars with changing ionic strength from 0.04 to 0.10 mol $kg^{-1}$ by use of acetate buffer. K values enhance with increasing ionic strength and temperature, but decrease with elevating pressure. From K values, we obtained the partial molar volume change and some other thermodynamic parameters. From the values of enthalpy, entropy and isoequilibrium temperature (649 K), we concluded that the dissociation of m-chloroanilinium ion mentioned above is controlled by enthalpy.

Preparation of Composite Membranes for Recovery of Unreacted Olefin Monomers (미반응 올레핀계 모노머 회수를 위한 복합막의 제조)

  • Kim, Hyun-Gi;Kim, Sang-Yong;Kim, Sung-Soo
    • Membrane Journal
    • /
    • v.20 no.4
    • /
    • pp.297-303
    • /
    • 2010
  • Composite membranes were prepared for membrane/cold condensation process for recovery of unreacted olefin monomer from the polyolefin polymerization process by solution coating and plasma polymerization processes. Poly(dimethylsiloxane) (PDMS) solution was coated on polysulfone (PSF) support and increase of prepolymer content in solution made more dense membrane structure to result in the increase of separation factor while absolute flux decreased. Permeation of organic materials through the composite membranes follows the sorption and diffusion mechanism, which brought about the results that separation factor increased with critical temperature of the organic materials, and that flux increased with the increase of the molar volume. Crosslinking period affected the permeation characteristics. Other types of composite membranes were fabricated by plasma polymerization of siloxane materials on polypropylene (PP) and PSF supports. PP was tested as a support for composite membranes, which had not been used so far in solution coating process, and plasma polymerization made the composite membranes equivalent performances to those of membranes prepared by solution coating process.

Isothermal Vapor-Liquid Equilibria at 333.15K and Thermodynamic Excess Properties for the Binary System of Methanol+Dimethyl Carbonate (Methanol+Dimethyl Carbonate 혼합계의 333.15 K 등온 기-액 평형과 열역학 과잉 물성)

  • Han, Kyu-Jin;Park, So-Jin
    • Korean Chemical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.387-392
    • /
    • 2005
  • Recently, dimethyl carbonate (DMC) is considered as an alternative of MTBE (methyl tert-butyl ether), additive for non-leaded gasoline with their fast biodegradation rate and low toxicity. DMC is usually synthesized so far by oxidative carbonylation of methanol, and recently developed synthetic process is also started with methanol. Since the phase equilibria of the system, consisted of DMC and methanol or other reaction products on different temperature and pressure is necessary for the optimum separation process design and operation. However the reported phase equilibria and physical properties for DMC mixtures in the Dortmund Data Bank (DDB; thermodynamic property data bank) are quite rare. Besides, infinitely dilute properties are not found. In this work, isothermal vapor-liquid equilibria at 333.15 K for methanol+DMC binary system and mixing properties, excess molar volume and viscosity deviation at 298.15 K are directly measured and correlated. Additionally, infinitely dilute activity coefficient of methanol in the DMC solvent at three different temperatures are measured and compared with predicted values using modified UNIFAC (Dortmund).

3D quantitative analysis and SEM qualitative analysis of natural antagonist enamel opposing CAD-CAM monolithic zirconia or lithium disilicate tooth-supported crowns versus enamel opposing natural enamel

  • Piyarat Woraganjanaboon;Chuchai Anunmana
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.12-24
    • /
    • 2024
  • PURPOSE. This study aimed to evaluate the maximum vertical wear, volume wear, and surface characteristic of antagonist enamel, opposing monolithic zirconia or lithium disilicate crowns. MATERIALS AND METHODS. The study comprised 24 participants (n = 12), who were randomly allocated to receive either a 5 mol% Y-TZP or a lithium disilicate crown in positions which would oppose the natural first molar tooth. The contralateral first molar along with its antagonist was considered as the enamel opposing natural enamel control. Data collection was performed using an intraoral scanner and polyvinylsiloxane impression. The means of the maximum vertical loss and the volume loss at the occlusal contact areas of the crowns and the various natural antagonists were measured by 3D comparison software. A scanning electron microscope was subsequently used to assess the wear characteristics. RESULTS. The one-year results from 22 participants (n = 11) indicated no significant differences when comparing the zirconia crown's antagonist enamel (40.28 ± 9.11 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (38.91 ± 7.09 ㎛, 0.04 ± 0.02 mm3) (P > .05). Also, there is no significant differences between lithium disilicate crown's antagonist enamel (47.81 ± 9.41 ㎛, 0.04 ± 0.02 mm3) and the natural enamel wear (39.11 ± 7.90 ㎛, 0.04 ± 0.02 mm3) (P > .05). CONCLUSION. While some studies suggested that monolithic zirconia caused less wear on opposing enamel than lithium disilicate, this study found similar wear levels to enamel for both materials compared to natural teeth.

In-depth morphological study of mesiobuccal root canal systems in maxillary first molars: review

  • Chang, Seok-Woo;Lee, Jong-Ki;Lee, Yoon;Kum, Kee-Yeon
    • Restorative Dentistry and Endodontics
    • /
    • v.38 no.1
    • /
    • pp.2-10
    • /
    • 2013
  • A common failure in endodontic treatment of the permanent maxillary first molars is likely to be caused by an inability to locate, clean, and obturate the second mesiobuccal (MB) canals. Because of the importance of knowledge on these additional canals, there have been numerous studies which investigated the maxillary first molar MB root canal morphology using in vivo and laboratory methods. In this article, the protocols, advantages and disadvantages of various methodologies for in-depth study of maxillary first molar MB root canal morphology were discussed. Furthermore, newly identified configuration types for the establishment of new classification system were suggested based on two image reformatting techniques of micro-computed tomography, which can be useful as a further 'Gold Standard' method for in-depth morphological study of complex root canal systems.