• Title/Summary/Keyword: moisture measurement

Search Result 561, Processing Time 0.031 seconds

Measurement of Moisture Contents using Recovery Voltage Method and Karl-Fischer Method (Karl-Fischer법과 회복전압법을 이용한 수분량 검출 비교 특성)

  • Kim, Hyung-Min;Kim, Jae-Hoon;Kim, Ju-Han;Han, Sang-Ok;Lee, Sei-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.76-78
    • /
    • 2005
  • Moisture contents measurement is frequently used as one of parameters for degradation diagnosis of transformer insulation. In general Karl-Fisher method is mainly used for moisture contents till now. But this method is inconvenient because of dismounting transformer for sampling oil or paper, and also partial sampling. At latest Recovery Voltage Method(RVM) is noticed for complement of this method. RVM can directly estimate moisture contents of transformer insulations in field without dismounting transformer. In this paper the accelerated aging process of oil-paper samples have been investigated at a temperature up to 140$^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. Next to, we have estimated moisture contents using both Karl-Fisher Titration Method and RVM. And we have compared with Karl-Fisher Titration Method and RVM for estimating moisture contents. At last we have verified reliability of RVM which is new measurement method.

  • PDF

A Study on the Changes in the Oil and Moisture Condition of Facial Skin in Women in their 20s and 30s (20-30대 여성의 안면 피부 유·수분 상태 변화 연구)

  • Choi, Ji-woo;Lee, Yoo-jeong;Shin, Sae-young
    • Journal of Fashion Business
    • /
    • v.25 no.4
    • /
    • pp.1-13
    • /
    • 2021
  • As interest in skin care increases, this study aims to contribute to the development of the beauty self-care market by providing basic data through the measurement of the oil and moisture skin condition of women in their 20s and 30s. The study was conducted from November 27, 2020 to January 31, 2021, with 20 women in their 20s and 30s divided into 4 groups, A~D, by age, 5 per group. Skin measurements were taken four times at 4 hour intervals at 0H, 4H, 8H, and 12H based on the first measurement that was taken within 30 minutes after waking up, and the oil and moisture indices were observed over time. As a result, both T and U zones showed significant differences in moisture levels over time, with no difference between groups for both T and U zones. Moisture decreased the most between 0H to 4H, and moisture changed the least between 4H to 8H. Changes in moisture increased the similar at 0H and 12H. The oil condition changed more irregularly compared to moisture over time, but all groups showed lower oil content in the U-zone compared to the T-zone. Overall, the facial oil and moisture conditions of women in their 20s and 30s changed over time, indicating that the skin changes in real time. The fact that the skin data, which was measured in the primary activity living environment, can be used as basic research data in the beauty self-care market is meaningful.

Development of Moisture Content Measurement Device for Paddy Rice using Microwave Free Space Transmission (마이크로파 자유공간 전송을 이용한 산물벼 함수율 측정장치 개발)

  • 김기복;김종헌;노상하
    • Journal of Biosystems Engineering
    • /
    • v.24 no.3
    • /
    • pp.235-242
    • /
    • 1999
  • This study was conducted to develop a grain moisture meter using microwave free space transmission technique at X-band frequency. The 10.5GHz microwave oscillator using a dielectric resonator was designed and fabricated to transmit electromagnetic wave through standard horn antenna to a sample holder with the wetted Hwasung and Chuchung rough rice(12.00∼26.25%). To detect the output voltage of transmitted wave from receiving horn antenna, the detector was composed of shottkey diode and RF impedance matching circuit. The regression model for measurement of grain moisture content was developed. Its correlation coefficient and standard error of prediction (SEP) were found to be 0.9882 and 0.657 respectively between measure and predicted moisture contents.

  • PDF

New Density-Independent Model for Measurement of Grain Moisture Content using Microwave Techniques

  • Kim, Jong-Heon;Kim, Ki-Bok;Noh, Sang-Ha
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.72-78
    • /
    • 1997
  • A free space transmission method using standard gain horn antennas in the frequency range from 9.0 to 10.5GHz is applied to determine the dielectric properties of grain such as rough rice ,brown rice and barley. The dielectric constant and loss factor, which depend on the moisture content of the wetted grain are obtained from the measured attenuation and phase shift by vector network analyzer. The moisture content of grain varied from 11 to 25% based on this wetted condition. The measured values of dielectric constants as a function of moisture density are compared with values of those obtained using he predicted model for estimating dielectric constants of grain. The effect of density fluctuation, high is an important parameter governing the dielectric properties of grain, on the dielectric constant and loss factor is presented. A new density-independent model in terms of measured attenuation an moisture density is proposed of reducing the effects of density fluctuation on the moisture content measurement.

  • PDF

Measurements of dielectric constants of soil to develop a landslide prediction system

  • Rhim, Hong Chul
    • Smart Structures and Systems
    • /
    • v.7 no.4
    • /
    • pp.319-328
    • /
    • 2011
  • In this study, the measurements of the dielectric constants of soil at 900 MHz and 1 GHz were made to relate those properties to the moisture content of the soil. This study's intention was to use the relationship between the dielectric constant and the moisture content to develop a landslide prediction system. By monitoring the change of the moisture content within the soil using ground penetrating radar (GPR) systems in the field, the possibility of a landslide is expected to be detected. To establish a database for the dielectric constants and the moisture content, the measurements of soil samples were made using both an open-ended dielectric coaxial probe and the GPR. Based on the measurement results, correlations between the GPR and reflector for each frequency at 900 MHz and 1 GHz were found for the dielectric constants and the moisture content. Finally, the mechanism of the measurement device to be implemented in the field is suggested.

Development of Soil Moisture Monitoring System for Effective Soil Moisture Measurement for Hillslope Using Flow Distribution Algorithm and TDR (산지사면의 효과적인 토양수분 측정을 위한 흐름분배 알고리즘과 TDR을 이용한 토양수분 측정망의 구성)

  • Kang, Chang-Yong;Kim, Sang-Hyun;Jung, Sung-Won;Kim, Won
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.1
    • /
    • pp.31-41
    • /
    • 2004
  • A soil moisture measuring method of hillslope for Korean watershed is developed to configure spatial-temporal distribution of soil moisture. Intensive surveying of topography had been performed to make a digital elevation model(DEM). Flow distribution algorithms were applied and a measurement system was established to maximize representative features of spatial variation. Soil moisture contribution mechanisms of rainfall-runoff process have been derived. Measurements were performed at the right side hillslope of Buprunsa located at the Sulmachun watershed. A Multiplex system has been operated and spatial-temporal soil moisture data have been acquired. Relatively high correlation relationship between flow distribution algorithm and measurement data can be found on the condition of high humidity.

Determination of Human Skin Moisture in the Near-Infrared Region from 1100 to 2200 nm by Portable NIR System (1100∼2200 nm 파장 영역의 휴대용 근적외선 분광분석기를 이용한 사람피부의 수분측정)

  • 안지원;서은정;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.3
    • /
    • pp.148-153
    • /
    • 2003
  • Skin moisture is an important factor in skin health. Measurement of moisture content can provide diagnostic information on the condition of skin. In this study, a portable near-infrared (NIR) system was newly integrated with a photo diode array detector that has no moving parts, and this system has been successfully applied for the evaluation of human skin moisture. Diffuse reflectance spectra were collected and transformed to absorbance using 1 nm step size over the wavelength range of 1100 nm to 2200 nm. Partial least squares regression (PLSR) was applied to develop a calibration model. For practical use for the evaluation of human skin moisture, the PLS model for human skin moisture was developed in vivo using the portable NIR system on the basis of the relative water content values of stratum corneum from the conventional capacitance method. The PLS model showed a good correlation. The calibration with the use of PLS model predicted human moisture with a standard error of prediction (SEP) of 3.5 at 1120∼1730 nm range. This study showed the possibility of skin moisture measurement using portable NIR system.

Comparative Analysis of Dynamic Moisture Movement Testers

  • Lee, Duck-Weon;Shim, Woo-Sub;Lim, Ho-Sun
    • Journal of Fashion Business
    • /
    • v.15 no.6
    • /
    • pp.40-55
    • /
    • 2011
  • The purpose of this research is to review testing principle, testing design and experimental results of the four dynamic moisture movement testers. The research analyzes Moisture Manager Tester (MMT), Alambeta Instrument, Dynamic Surface Moisture Movement Tester, and Gravimetric Absorbent Testing Method based on American Society for Testing and Material (ASTM) E 96 which is an international standard testing method. Although many of researches use ASTM E 96 to measure moisture movement on a fabric, it has several weaknesses, such as long experimental time and a physical change of sample by a holder of the frame. Hence, lots of researchers have studied and developed the new measurement systems measuring moisture management on a fabric or garment and ultimately mimic heat energy and perspiration created by the human body. These moisture management systems use a variety of parameters, such as electricity, color, and sensor to measure their movement in the fabric. Through comparison with the existing tester (ASTM E 96), the research recognizes the strength and weakness in the dynamic moisture movement testers.

An Fundamental Study on the Measurement of Cement Mortar Unit-Water Content Using High Frequency Moisture Sensor (고주파 수분 센서를 이용한 시멘트 모르타르의 단위수량 측정에 관한 기초적 연구)

  • Cho, Yang-Je;Kim, Min-Seo;Yoon, Jong-Wan;Park, Tae-Joon;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.6-7
    • /
    • 2020
  • The unit-water content of concrete is one of the important factors in determining the quality of concrete and is directly related to the durability of the construction structure, and the current method of measuring the unit-water content of concrete is applied by the Air Meta Act and the Electrostatic Capacity Act. However, there are complex and time-consuming problems with measurement methods. Therefore, high frequency moisture sensor was used for quick and high measurement, and unit-water content of mortar was evaluated through machine running and deep running based on measurement big data.

  • PDF

The moisture measurement of sintering material by the NIR simulator (근적외선 분광법을 이용한 simulator를 통한 소결원료 수분측정)

  • 이진우;정재인
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1273-1275
    • /
    • 1996
  • Moisture measurements of s intering materials were performed using the simulator which can simulate various conditions taking place at the belt-conveyor of sintering process. The moisture sensor used in this experiment is NIR moisture meter(JE-330, KETT Electric Lab.). Using the simulator, we measured the moisture contents of sintering materials at different conditions. We found that the moisture content decreased as the rotation speed increased and the size of the sintering materials became smaller.

  • PDF