• Title/Summary/Keyword: moisture conditioning

Search Result 105, Processing Time 0.025 seconds

Analysis for Temperature and Relative Humidity of Showcase in Exhibition Hall Operated Intermittent Air Conditioning (간헐공조 전시관내 유물 진열장의 온·습도 환경 분석)

  • Lee, Sun Myung;Lim, Bo A;Kim, Seojin
    • Journal of Conservation Science
    • /
    • v.29 no.4
    • /
    • pp.311-320
    • /
    • 2013
  • The showcase has insufficient temperature control, but it has excellent humidity control. The annual average temperature and relative humidity inside the showcase was $18.8^{\circ}C$ and 60.3%, respectively, and the showcase showed lower temperature and higher humidity than the exhibition room. The temperature inside the showcase appeared with high variation according to the seasons, while relative humidity was ranging from 59% to 61% regardless of the seasons. The showcase showed high temperature and humidity likewise the exhibition room in summer. In addition, lowering of temperature was elevated relative humidity according to the operation of air conditioner in summer. A moisture problem occurred because the temperature and humidity differences between the exhibition room and showcase were large according to the operation of air conditioner in winter. PI for temperature and relative humidity inside the showcase is 18.0%, and it means conservation environment for exhibition is unsuitable. In particular, continuous management of temperature and humidity inside the showcase is required because PI in the summer and winter is less than 1.0%.

Vibration Analysis of Separation Screen in a Recycling Plant of Moisturized Construction Wastes (고함수율의 건설폐기물 폐 토속에 포함된 이물질 선별을 위한 분리스크린의 진동해석)

  • Moon, Byung-Young;Bae, Hyo-Dong;Kwag, Kwang-Hun;Bae, Kee-Sun;Song, Ha-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.8
    • /
    • pp.526-533
    • /
    • 2008
  • In this study, theoretical super screen vibration analysis has been carried out to predict the dynamic characteristics of interactive waste particles. In order to approach these problems, it is necessary to have a fundamental understanding the screening process and the process of both the remaining and the passed material on a screen with several interacting screen planes based on Soldinger(1999) was discussed. Here, the vibrating screen is composed of three assemblies such as screen, wastes guide, and supported screen as shown in Fig. 1. This model is regarded vibrator as the system of screen fixed tilt plates. Then materials(or particles) of different size is to be separated by using the eccentric vibrator and classifying tilt plates. As well moisturized construction wastes is more efficient to separate than moisture-less it. In processing separate mechanism, the more materials is light, the more staying time is long. Thus much lighter construction wastes(wood, Styrofoam, etc) and heavier materials are separated by staying time delay in a super screen. The design results, separation screen were able to know that small and larger particles are conspicuous difference each motion character according to trajectory particles, and small particles raise the probability in classifying tilt plates.

Modelling of the Heat and Mass Transfer in a Liquid Desiccant Dehumidifier with Extended Surface (확장표면을 적용한 액체식 제습기의 열물질 전달 모델링)

  • Chang, Y.S.;Lee, D.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.303-311
    • /
    • 2011
  • This study presents a new idea of liquid desiccant dehumidifier with extended surface to improve the compactness. Extended surface is inserted between vertical cooling tubes, and the liquid desiccant flows down along the tube walls and the extended surface as well. Though the extended surface contributes to the increase in the mass transfer area, the effect tends to be limited because less conductive non-metallic materials need to be applied due to the high corrosiveness of liquid desiccant. To analyze the effects of the extended surface insertion, mathematical modelling and numerical integration are performed for the heat and mass transfer in the liquid desiccant dehumidifier. The results show that, though the liquid desiccant on the extended surface is heated due to the moisture absorption, the temperature can be maintained by periodic mixing at the contact points between the tube and the extended surface with the liquid desiccant stream from the tube side at a relatively low temperature. This implies the absorption heat from the extended surface side can be removed effectively by mixing, which leads to a substantial improvement of the dehumidification in the liquid desiccant dehumidifier with extended surface. When the interval of the extended surface, $p_e/L$, is less than 0.1, the dehumidification is shown to increase by more than two times compared with that without extended surface.

Heavy Metal Contents of Compost from Household Food Waste (음식쓰레기 퇴비화과정 중 중금속함량 변화)

  • Seo, Jeoung-Yoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.4 no.1
    • /
    • pp.23-31
    • /
    • 1996
  • The heavy metal concentration in mixed and separately collected household food waste, and their compost during the composting period was analysed. The mixed and separately collected food waste had Cd content of 8 mg/kg in spring and its content of 13 mg/kg in winter respectively. Its content was higher than by-product compost limit value(5 mg Cd/kg). Cd concentration in separately collected food waste in a house was higher in January, February, April and May than by-product compost limit value (5 mg Cd/kg). When Cd concentration in the initial composting material was higher than 5 mg/kg, its concentration in the compost of household food waste during the composting period was higher than by-product compost limit value, but it was not accumulated in the compost during the composting period. Fly ash was added to separately collected household food waste to adjust its moisture content for composting. Its addition had moisture conditioning and Cd concentration reducing effect in the compost. The average one month composted fresh compost from the mixed collected household food waste was matured in a pile out of doors for 7 months with turning the pile once a month and its heavy metal concentration was examined. Accumulation of the heavy metals in the compost did not occur during the composting period, because they were washed out during the rainfall.

  • PDF

Performance Test of Low Temperature Regeneration Polymeric Desiccant Rotor (고분자 제습로터의 저온재생 성능시험)

  • Lee, Jin-Kyo;Lee, Dae-Young;Oh, Myung-Do
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.629-632
    • /
    • 2009
  • The polymeric desiccant rotor is made from the super absorbent polymer by ion modification. The moisture sorption capacity of the super desiccant polymer(SDP) is 4 to 5 times larger than those of common desiccant meterials such as silica gel or zeolite. It is also known that SDP can be regenerated even at the relatively low temperature. To fabricate the desiccant rotor, firstly the SDP was laminated by coating the SDP on polyethylene sheet. Then corrugated and rolled up into a rotor. The diameter, the depth, the dimensions of the corrugated channel, etc. were pre-determined from numerical simulation on the heat and mass transfer in the desiccant rotor. The dehumidification performance was tested in a climate chamber. The relevant tests were carried out at the process air inlet temperature of $32^{\circ}C$, the regeneration air inlet temperature of $60^{\circ}C$ and the inlet dew-point temperature of both the process air and the regeneration air of $18.5^{\circ}C$, when the rotation period is long, the moisture sorption is not effective. In the desiccant rotor developed in this study, the optimum rotation period is found about 350s at the regeneration temperature of $60^{\circ}C$. It was found from further experiments that the optimum rotation tends to decreases as the regeneration temperature increases. Meanwhile, the outlet temperature of the process air deceases monotonically as the rotation period increases.

  • PDF

Effect of Ozone Injection on Dewaterability and Thickening of Sewage Sludge (하수 슬러지 농축 및 탈수성에 미치는 오존의 영향)

  • Hwang, Kyeoung-Sa;Kim, Moon-Ho;Bae, Yoon-Sun;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.800-808
    • /
    • 2005
  • It is required to propose an alternatives for appropriate sludge treatment owing to persistent construction of sewage treatment plant and increase of sewage sludge quantity. In order to treat sludge more efficiently, the methods which reduce the cost of sludge treatment have been studied such as sludge reduction and conditioning. Especially ozone treatment reduces solid quantity and improves separation of solid-liquid at the same time. Therefore ozone treatment have a positive effect on reduction and stabilization of sludge. So, this study applied ozone to sewage sludge and induced cell destruction of sludge. By comparing with the correlation between thickening and dewatering, and evaluating moisture content and solubilization of cake, this study verificates the effect of process improvement for ozone pre-treatment. In J-STP case, according to ozone dose solid flux increased about 12 times from $1kg/m^2{\cdot}h$ to $12kg/m^2{\cdot}h$. Also this plant were capable to shorten thickening time from 40 minutes to 6~7 minutes. Thus it is expected to reduce volume and retention time of thickener. On pH effect factor, dewatering at pH4 was more than at pH11, $3.05{\times}10^{11}$ and $3.82{\times}10^{11}(m/kg)$. But effect of pH was analogous to ozone, $2.81{\times}10^{11}(m/kg)$. The effect of pH on thickening was similar to law sludge, $0.68(kg/m^2{\cdot}h)$, and the effect of ozone injection on thickening was the biggest, $3.45(kg/m^2{\cdot}h)$. The COD solubilization rate improved from about 5 to 30%. So it is judged that we are able to utilize most solubilized sludge to another sewage treatment plants.

Effects of Fatigue Strength by Solder Ball Composition (솔더볼 조성에 의한 피로강도의 영향)

  • 김경수;김진영
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.3
    • /
    • pp.127-131
    • /
    • 2004
  • Package reliability test was conducted to investigate the effect of solder composition on the ball fatigue strength for BGA (Ball Grid Array) packaging. The test pieces are assembled using eutectic composition 63Sn/37Pb, 62Sn/36Pb/2Ag, and 63Sn/34.4Pb/2Ag/0.5Sb solder after pre-conditioning at MRT Lv 3 (Moisture Resistance Test Level) and then conducted under T/C (Temperature Cycle test). For each case, the ball shear strength was obtained and micro structure photos were taken. SEM (scanning electron microscope) and EDX (Energy Dispersive X-ray) were used to the analyze failure mechanism. The growth rate of Au-Sn intermetallic compound in Sn63Pb34.5Ag2Sb0.5 solder was slow when compared to 63Sn/37Pb solder and 62Sn/36Pb/2Ag solder. The degradation of shear strength of solder balls caused by solder composition was discussed.

A Study on Performance Characteristics of a Dehumidifier with Multi-layer Type Heat Exchangers Varying Frontal Air Velocity (다층형 열교환기를 이용한 제습기의 전면 풍속 변화에 따른 성능 특성에 관한 연구)

  • Ku, Hak-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2323-2327
    • /
    • 2010
  • The experimental apparatus consists of dehumidifier with multi-layer type heat exchangers to remove the moisture from automatic equipments, semiconductors, and manufacturing processes under the low temperature environment, and chemical production lines which are likely to take moisture. The major components of this system are four evaporators with different fin pitch, two compressors, two condensers and an expansion valve. In this study, the performance characteristics of dehumidifier is analyzed by the variations of frontal air velocity in the first heat exchanger(evaporator). The cooling capacity of each heat exchanger is acquired by the enthalpy calculating from measuring point of temperature and relative humidity of the first heat exchanger from 1.0m/s to 4.0m/s with increasing interval 0.5m/s, and the front air velocity. As a result, it is found that cooling capacity of the first heat exchanger showed the best cooling capacity when its frontal air velocity is 2.0 m/s.

Development of High Efficiency Dehumidifiers in low temperature (저온에서 고효율 제습기 개발)

  • Kim, Jong-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.206-211
    • /
    • 2016
  • Various applications require dry air at low temperature, such automation equipment, semiconductor manufacturing, chemical production lines, and coating processes for the shipbuilding industry. Four evaporators for low temperature (below $0^{\circ}C$) were installed for a dehumidification system. Moist air is cooled sequentially over three evaporators. The first evaporator has an evaporation temperature of $13^{\circ}C$, that of the second evaporator is $5^{\circ}C$, and that of the third evaporator is maintained at $-1.3^{\circ}C$. In the fourth evaporator implantation thereby the moisture contained in the moisture air. A pressure regulator (CPCE 12) is used at this point and is defrosted when the vapor pressure is below a set value. The non-implantation moisture of the air is a heating system that uses the waste heat of a condenser with high temperature. It develops the cooling type's dehumidifier, which is important equipment that prevents the destruction of protein and measures the temperature and humidity at each interval by changing the front air velocity from 1.0 m/s to 4.0 m/s. The cooling capacity was also calculated. The greatest cooling capacity was 1.77 kcal/h for a front air velocity of 2.0 m/s

Accelerated Test Program for Durability Characteristics of GFRP Rebars (내구특성 파악을 위한 GFRP 보강근의 촉진실험 연구)

  • Kim, Hyeong-Yeol;You, Young-Jun;Park, Young-Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.1
    • /
    • pp.157-164
    • /
    • 2006
  • This paper presents the durability characteristics of commercially available CFRP rebars under various environmental conditions. Two types of GFRP rebars were tested by using an accelerated aging method. A total of 264 rebar specimens were conditioned up to 132 days in the moisture, chloride. alkaline, and freeze-thaw environmental conditions. The durability characteristics of conditioned rebars were obtained by comparing the tensile strength, horizontal shear strength, and elastic modulus between the unconditioned and conditioned GFRP rebars. The test results indicated that the mechanical properties of GFRP were significantly reduced after conditioning. Long-term degradation of GFRP rebars was also estimated using the results of a short-term durability test.