• Title/Summary/Keyword: modified t-test

Search Result 606, Processing Time 0.027 seconds

Characterization of Fracture Transmissivity for Groundwater Flow Assessment using DFN Modeling (분리단열망개념의 지하수유동해석을 위한 단열투수량계수의 정량화 연구)

  • 배대석;송무영;김천수;김경수;김증렬
    • The Journal of Engineering Geology
    • /
    • v.6 no.1
    • /
    • pp.1-13
    • /
    • 1996
  • The fracture transmissivity($T_f$) is the most important parameter of fracture in assessing groundwater flow in fractured rock masses by using the DFN(Discrete Fracture Network) modeling. $T_f$, the most sensitive parameter m DFN modeling, is dependent upon aperture, size and filling characteristics of each fracture set. In the field test, the accuracy of $T_f$ can be increased with Borehole Acoustic Scanning (Televiewer) and Fixed Interval Length(FIL) test in constant head. $T_f$ values measured from FIL test was modified and estimated by each fracture set on the basis of the Cubic Law and the information of aperture and filling characteristics obtained from Televiewer. The modified $T_f$ results in the increase of confidence and reliability of modeling results including the amount of tunnel inflow.And, this approach would reduce the uncertaintity of the assessment for groundwater flow in fractured rock masses using the DFN modeling.

  • PDF

Improved Statistical Testing of Two-class Microarrays with a Robust Statistical Approach

  • Oh, Hee-Seok;Jang, Dong-Ik;Oh, Seung-Yoon;Kim, Hee-Bal
    • Interdisciplinary Bio Central
    • /
    • v.2 no.2
    • /
    • pp.4.1-4.6
    • /
    • 2010
  • The most common type of microarray experiment has a simple design using microarray data obtained from two different groups or conditions. A typical method to identify differentially expressed genes (DEGs) between two conditions is the conventional Student's t-test. The t-test is based on the simple estimation of the population variance for a gene using the sample variance of its expression levels. Although empirical Bayes approach improves on the t-statistic by not giving a high rank to genes only because they have a small sample variance, the basic assumption for this is same as the ordinary t-test which is the equality of variances across experimental groups. The t-test and empirical Bayes approach suffer from low statistical power because of the assumption of normal and unimodal distributions for the microarray data analysis. We propose a method to address these problems that is robust to outliers or skewed data, while maintaining the advantages of the classical t-test or modified t-statistics. The resulting data transformation to fit the normality assumption increases the statistical power for identifying DEGs using these statistics.

How Does 12-weeks of Taekwondo Training Effect Older Persons' Functional Fitness: A Preliminary Study

  • Daniel Sullivan;Mike Climstein;Ben Exton;Luke Delvecchio
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.19 no.1
    • /
    • pp.1-10
    • /
    • 2024
  • PURPOSE: This pre-post intervention study aimed to examine the effects of a 12-week supervised modified Taekwondo exercise program on the functional fitness of community-dwelling older adults. METHODS: 10 participants (mean age: 72.3 ± 4.6 years) completed the program over a 12-week period. The intervention consisted of Taekwondo-based exercises modified for older persons. Changes to functional fitness were measured using the finger-to-nose test, functional reach test, timed up and go test, 30-second sit-to-stand test, 30-second arm curl test, Chester step test, chair sit-and-reach test, and back scratch test. Participants were assessed prior to the training and after the final training session, changes were measured using descriptive statistics and paired sample 't' tests. RESULTS: Effect sizes ranged from small to large (Cohen's d = .22 to 1.23). The exercise program was well- tolerated by participants, with a high level of engagement and no attrition for the duration of the program. Results showed significant improvements in most measures of functional fitness (p < .05) except for the back scratch test (p = .051). CONCLUSION: These findings suggest a well-designed, supervised, modified Taekwondo exercise program can significantly improve functional fitness in older adults.

The Retardation Behaviors due to a Single Overload and High-Low Block Loads, and Retardation Model in 7075-T73 Aluminum Alloy (7075-T73 알루미늄 합금의 단일과대 및 고-저블럭하중에 의한 지연거동과 수명예측 모델)

  • 김정규;송달호;박병훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.9
    • /
    • pp.1605-1614
    • /
    • 1992
  • The effects of % overload (% O.L), baseline stress intensity factor range (.DELTA. $K_{b}$) and dimension-less crack depth (a/W) are examined for the retardation behaviors after a single overload and high-low block loads in 7075-T73 aluminum alloy. And wheeler model, which is one of the fatigue life prediction models, is modified to predict retardation life using these test results. The retardation cycles( $N_{d}$) increased with a decrease in a/W and an increase in % O.L. and (.DELTA. $K_{b}$) These effects are more severe after high-low block loads than single overload. In the case of single overload, the main mechanisms of the retardation are the crack closure and the relaxation of K due to crack branching. But in the case of high-low block loads, that of the main mechanism is the crack closure caused by the accumulated compressive residual stree at the crack tip, which is related with the contact of fracture surfaces. Test results were multiple regression analyzed and got regressed shaping correction factors, (n)$_{REG}$, as function of %O.L., a/W and (.DELTA. $K_{b}$) Wheeler model is modified by using these (n)$_{REG}$. The number of delay cycles calculated by modified Wheeler model were in good agreement with the test results of this study.y.udy.y.y.y.

Accelerated life test plan under modified ramp-stress loading with two stress factors

  • Srivastava, P.W.;Gupta, T.
    • International Journal of Reliability and Applications
    • /
    • v.18 no.2
    • /
    • pp.21-44
    • /
    • 2017
  • Accelerated life tests (ALTs) are frequently used in manufacturing industries to evaluate the reliability of products within a reasonable amount of time and cost. Test units are subjected to elevated stresses which yield quick failures. Most of the previous works on designing ALT plans are focused on tests that involve a single stress. Many times more than one stress factor influence the product's functioning. This paper deals with the design of optimum modified ramp-stress ALT plan for Burr type XII distribution with Type-I censoring under two stress factors, viz., voltage and switching rate each at two levels- low and high. It is assumed that usage time to failure is power law function of switching rate, and voltage increases linearly with time according to modified ramp-stress scheme. The cumulative exposure model is used to incorporate the effect of changing stresses. The optimum plan is devised using D-optimality criterion wherein the ${\log}_{10}$ of the determinant of Fisher information matrix is maximized. The method developed has been explained using a numerical example and sensitivity carried out.

  • PDF

The Effects of the modified Constraint-Induced Movement Therapy on Upper Function and Activities of Daily Living in Subacute Stroke Patients (수정된 건측억제-환측유도치료(mCIMT)가 아급성기 뇌졸중환자의 상지기능과 일상생활수행능력에 미치는 영향)

  • Bang, Dae-Hyouk;Choi, Sung-Jin;Shin, Won-Seob
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.2
    • /
    • pp.245-252
    • /
    • 2013
  • PURPOSE: The aim of this study is to verify the effectiveness of modified constraint-induced movement therapy(mCIMT) on upper function and activities of daily living in people with subacute stroke patients. METHODS: Eighteen participants, with subacute stroke that were randomly assigned to either the experimental group(n=9) or the control group(n=9). For subjects from the experimental group modified Constraint-Induced Movement Therapy was performed. exercise program, the patient trained in affected side upper extremity with restricted non-affected side for 1 hour and using in activity daily living for 4 hours for five times per week, during 4 weeks. For subjects from the control group, conventional upper extremity training was performed. Outcomes such as the box and block test(BBT), Fugl-Meyer motor function assessment(FMA), and modified Barthel index(MBI) were measured before and after training. Between-group and within-group comparisons were analyzed by using Independent t-test and Paired t-test respectively. RESULTS: These finding suggest that experimental group was significant increase in BBT, FMA, MBI(p<.05). In comparison of two group, experimental group was high upper function and activity daily living than control group. CONCLUSION: This study showed experimental group can be used to improve upper function and activity daily living than control group. Thus it indicates that mCIMT will be more improved through the continued upper extremity exercise program.

Modified T-Plate Interpositional Arthroplasty for Temporomandibular Joint Ankylosis: A New and Versatile Option

  • Ahmad, Imran;Mir, Mohd Altaf;Bariar, Lalit Mohan
    • Archives of Plastic Surgery
    • /
    • v.42 no.6
    • /
    • pp.716-720
    • /
    • 2015
  • Background This study has been conducted with the aim of evaluating modified T-plate interpositional arthroplasty. Methods A prospective comparative study in patients admitted with temporomandibular joint ankylosis. Ankylotic temporomandibular joint arthroplasty included condylectomy gap arthroplasty in 7, temporalis muscle flap interpositional arthroplasty in 8, and modified T-plate interpositional arthroplasty in 13 cases. The patients were followed for three years. Collected data were tabulated and subjected to Fisher's exact test, chi-square test and probability estimation. Results A significant increase in interincisal distance of 32 mm was seen in 12 (92.31%) patients in the T-plate interposition group, in 2 (25%) cases of the temporalis muscle flap interposition group, and in 1 case (14.28%) of the condylectomy group at 12, 24, and 36 months. Re-ankylosis was observed in 1 case (9.69%) of the T-plate interposition group, while as it was observed in 4 (50%) cases in the temporalis muscle flap interposition group and 4 (57.14%) cases in the condylectomy group, and these differences were statistically significant. Conclusions Our clinical experience with the use of the T-plate over the past 5 years has been encouraging, and our physiotherapy technique is quite simple. Even illiterate parents can assess it easily. Hence, we recommend this easy technique that does not damage the temporalis muscle for the management of temporomandibular joint ankylosis.

MODIFIED POSTERIOR TIME-STEP ADJUSTMENT TECHNIQUE FOR MDOF SYSTEM IN SUBSTRUCTURING PSEUDODYNAMIC TEST (부분구조 유사동적법에 있어 다자유도 시스템에 대한 수정 시간증분 조정기법)

  • 이원호;강정호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1998.10a
    • /
    • pp.473-480
    • /
    • 1998
  • The substructuring pseudodynamic test is a hybrid testing method consisting of a numerical simulation of the earthquake response of an analytical model and a loading test of a specimen. The substructuring pseudodynamic testing technique has been applied to various seismic experiments since it has advantages over the shaking table test to study dynamic behaviors of relatively large scale structures. However, experimental errors are inevitable in substructuring pseudodynamic testing. Some of these errors can be monitored during the test, but, due to limitations in control system, they cannot be eliminated. For example, one cannot control exactly the displacements that are actually imposed on the structures at each time step. This paper focuses on a technique to minimize the cumulative effect of such control errors for MDOF system. For this purpose, the modified posterior adjustment of the time increment from a target value $\Delta$t$_{n}$ to an adjusted value is performed to minimize the effect of the control errors for MDOF system.for MDOF system.

  • PDF

Low Speed Thrust Characteristics of a Modified Sonic Arc Airfoil Rotor through Spin Test Measurement

  • Lee, Jang-Chang
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.3
    • /
    • pp.317-322
    • /
    • 2012
  • The low speed aerodynamic characteristics for a modified sonic arc airfoil which is designed by using the nose shape function of sonic arc, the shape function of NACA four-digit wing sections, and Maple are experimentally investigated. The small rotor blades of a modified sonic arc and NACA0012 airfoil are precisely fabricated with a commercially available light aluminum(Al 6061-T6) and are spin tested over a low speed range (3000rpm-5000rpm). In a consuming power comparison, the consuming powers of NACA0012 are higher than that of modified sonic arcs at each pitch angle. The measured rotor thrust for each pitch angle is used to estimate the rotor thrust coefficient according to momentum theory in the hover state. The value of thrust coefficients for both two airfoils at each pitch angle show almost constant values over the low Mach number range. However, the rotor thrust coefficient of NACA0012 is higher than that of the modified sonic arc at each pitch angle. In conclusion, the aerodynamic performance of NACA0012 is better than that of modified sonic arcs in the low speed regime. This test model will provide a convenient platform for improving the aerodynamic performance of small scale airfoils and for performing design optimization studies.

A Comparison Study for the Fatigue Behavior of H/T and T/S Bolt Friction Joint (H/T 와 T/S 볼트 마찰이음의 피로거동 비교·검토)

  • JUN, Je Sang;WOO, Sang Ik;LEE, Seong Heang;JUNG, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.139-150
    • /
    • 1996
  • H/T(High Tension) bolt is generally being used in joining the members of steel structure. It has some difficulties in management such as an adequate fastening force and a selection of proper instrument for fastening. T/S(Torque Shear Type High Tension) bolt which is more convenient and easier than H/T bolt in quality control has recently been developed. T/S bolts are produced and widely used these days in domestic, but those have not a detail regulation for their on. Those are only being used according to the specification for the H/T bolts. In this study, we tried to confirm the soundness of T/S bolts by the fatigue test of the modified specimens. First, we measured the reduction rate of the initial axial force with time at bolts. Second, we investigated the slip forces of bolts when the test specimen is loaded in tension. Third, we implemented the fatigue tests. During the test, we measured the variation of the axial forces of bolts under the cyclic loading. Finally, we compared and analyzed the fatigue behavior of H/T and T/S bolt, by S-N curve diagrams that are obtained in this study.

  • PDF