• Title/Summary/Keyword: mode prediction

Search Result 852, Processing Time 0.021 seconds

Grounding Line of Campbell Glacier in Ross Sea Derived from High-Resolution Digital Elevation Model (고해상도 DEM을 활용한 로스해 Campbell 빙하의 지반접지선 추정)

  • Kim, Seung Hee;Kim, Duk-jin;Kim, Hyun-Cheol
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.545-552
    • /
    • 2018
  • Grounding line is used as evidence of the mass balance showing the vulnerability of Antarctic glaciers and ice shelves. In this research, we utilized a high resolution digital elevation model of glacier surface derived by recently launched satellites to estimate the position of grounding line of Campbell Glacier in East Antarctica. TanDEM-X and TerraSAR-X data in single-pass interferometry mode were acquired on June 21, 2013 and September 10, 2016 and CryoSat-2 radar altimeter data were acquired within 15 days from the acquisition date of TanDEM-X. The datasets were combined to generate a high resolution digital elevation model which was used to estimate the grounding line position. During the 3 years of observation, there weren't any significant changes in grounding line position. Since the average density of ice used in estimating grounding line is not accurately known, the variations of the grounding line was analyzed with respect to the density of ice. There was a spatial difference from the grounding line estimated by DDInSAR whereas the estimated grounding line using the characteristics of the surface of the optical satellite images agreed well when the ice column density was about $880kg/m^3$. Although the reliability of the results depends on the vertical accuracy of the bathymetry in this study, the hydrostatic ice thickness has greater influence on the grounding line estimation.

A Study on Heat Transfer Coefficient of a Perfluorocarbon Heat Pipe (Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구)

  • 강환국;김철주;김재진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.194-201
    • /
    • 1998
  • In electric commuter trains using AC motors, lots of GTO thyristors and diodes are needed for power controls. These semiconductors generate heat about 1~2 kW, and for cooling which perfluorocarbon(PFC) heat pipes have been in use for the last two decades. The present study was investigated on the effects of such important design parameters as structure of internal surface (grooved or smooth), fill charge ratio, and inclinating angle from a vertical on heat transfer coefficients at both evaporators and condensers. To obtain experimental data, several heat pipes of the same geometry of 520 mm long and diameter of 15.88 mm but different in fill charge ratio and internal surface structure were designed and fabricated. For prediction of the heat transfer coefficients, related expressions were examined and the results of calculations were compared with experimental data. Performance tests were conducted while heat pipes operated at mode of thermosyphons. High enhancements of heat transfer coefficient were obtained internal grooves. In these cases, the evaporating heat transfer coefficients distributed in the range of 2~5.5 kW/$m^2$K, with an increase of heat flux from 15~45 kW/$m^2$. These experimental data were in good agreement with Rohsenow's expression based on nucleate boiling when correction factor $C_R$=1.3 was encountered. In addition, the condensation heat transfer coefficients were distributed from 1.5 to 3.5 kW/$m^2$K, and the data were in good agreements with Nusselt's correlation, based on filmwise condensation on vertical plate, when choosing a correction factor $C_N=4$. A fill charge ratio of 40~100% were recommended, and the in clination angle effects were negligible when the angle was higher then 30$^{\circ}$.

  • PDF

Equivalent Transmission-Line Sections for Very High Impedances and Their Application to Branch-Line Hybrids with Very Weak Coupling Power

  • Ahn, Hee-Ran;Kim, Bum-Man
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.2
    • /
    • pp.85-97
    • /
    • 2009
  • As operating frequency is raised and as more integration with active and passive elements is required, it becomes difficult to fabricate more than 120 ${\Omega}$ characteristic impedance of a mierostrip line. To solve this problem, an equivalent high impedance transmission-line section is suggested, which consists mainly of a pair of coupled-line sections with two shorts. However, it becomes a transmission-line section only when its electrical length is fixed and its coupling power is more than half. To have transmission-line characteristics(perfect matching), independently of coupling power and electrical length, two identical open stubs are added and conventional design equations of evenand odd-mode impedances are modified, based on the fact that the modified design equations have the linear combinations of conventional ones. The high impedance transmission-line section is a passive component and therefore should be perfectly matched, at least at a design center frequency. For this, two different solutions are derived for the added open stub and two types of high impedance transmission-line sections with 160 ${\Omega}$ characteristic impedance are simulated as the electrical lengths of the coupled-line sections are varied. The simulation results show that the determination of the available bandwidth location depends on which solution is chosen. As an application, branch-line hybrids with very weak coupling power are investigated, depending on where an isolated port is located, and two types of branch-line hybrids are derived for each case. To verify the derived branch-line hybrids, a microstrip branch-line hybrid with -15 dB coupling power, composed of two 90$^{\circ}$ and two 270$^{\circ}$ transmission-line sections, is fabricated on a substrate of ${\varepsilon}_r$= 3.4 and h=0.76 mm and measured. In this case, 276.7 ${\Omega}$ characteristic impedance is fabricated using the suggested high impedance transmission-line sections. The measured coupling power is -14.5 dB, isolation and matching is almost perfect at a design center frequency of 2 GHz, showing good agreement with the prediction.

Lifetime test of batteries for BLE modules for site identification of vessel's crews and passengers (SIVCP) (SIVCP용 BLE 모듈의 배터리 수명시험)

  • Kwon, Hyuk-joo;Kim, Min-Gwon;Kim, Yoon-Sik;Lee, Sung-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.7
    • /
    • pp.754-759
    • /
    • 2015
  • Nowadays, short distance communication systems with low power energy (LPE) are developed for identification and monitoring of site identification of vessel crews and passengers (SIVCP). LPE communication modules, such as Bluetooth low energy (BLE) and Zigbee, are used for short distance communications with LPE. These modules enable 1:N communications and their popularity is growing since the modules can be mounted on movable objects, such as mobile devices and human body. When these modules are used, the important factor that affects their operation time and design are the capacity and size of battery. Therefore, they must be made as small as possible, and the battery should be selected to be slightly smaller than the module. In this study, we calculate the theoretical life of batteries used in SIVCP BLE modules using data sheet and discharge characteristic graph under the condition of a 1/250 transmission-ratio (TR). We thus calculate experimental life by measuring transmission current for the same TR, and low speed mode current for a 1/5000 TR and measure long-term experimental life using 1/25 TR for days. Through these experiments, we verify experimental methods for the prediction and extension of battery life that would enable us to select appropriate sizes of batteries based on vessel usage and passenger types. The selections of the module TR and battery size are important factors affecting the cost reduction of module design, the battery maintenance, and passenger convenience.

Research of Hydraulic Breaker with Rock Properties Predictability Using the ICT (ICT 융합기술을 활용한 암반특성 예측기능을 가진 유압 브레이커 개발에 관한 연구)

  • Yoon, Bok Joong;Lee, Kil Soo;Lim, Hoon;Lee, Ho Yeon;Lee, Myung Gyu;Kwon, Hyuk Jin;Kim, Kab Tae;Joo, Jin Moo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.7
    • /
    • pp.683-689
    • /
    • 2017
  • We have carried out the development for hydraulic breaker which can be operated by optimal mode with ICT convergence technology. This developed system can predict the rock properties. Moreover, this system can maximize the energy efficient with intelligent control of hydraulic system. In order to provide the optimal impact force, this system can measure the descending depth of piston with the proximity sensor and discriminate the rock properties with the measuring data and control the piston stroke using solenoid valve eventually. In addition, we have developed the controller, display module and operating device for cascade (multi-level impact) system and applied the module which can communicate each system by wireless communications. In conclusion, the control system which can control the multi-level impact in accordance with strength of rocks has been developed and approved by several field tests.

Numerical Prediction of Ultimate Strength of RC Beams and Slabs with a Patch by p-Version Nonlinear Finite Element Modeling and Experimental Verification (p-Version 비선형 유한요소모델링과 실험적 검증에 의한 팻취 보강된 RC보와 슬래브의 극한강도 산정)

  • Ahn Jae-Seok;Park Jin-Hwan;Woo Kwang-Sung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.17 no.4
    • /
    • pp.375-387
    • /
    • 2004
  • A new finite element model will be presented to analyze the nonlinear behavior of RC beams and slabs strengthened by a patch repair. The numerical approach is based on the p-version degenerate shell element including theory of anisotropic laminated composites, theory of materially and geometrically nonlinear plates. In the nonlinear formulation of this model, the total Lagrangian formulation is adopted with large deflections and moderate rotations being accounted for in the sense of von Karman hypothesis. The material model is based on hardening rule, crushing condition, plate-end debonding strength model and so on. The Gauss-Lobatto numerical quadrature is applied to calculate the stresses at the nodal points instead of Gauss points. The validity of the proposed p-version nonlinear finite element model is demonstrated through the load-deflection curves, the ultimate loads, and the failure modes of RC beams or slabs bonded with steel plates or FRP plates compared with available result of experiment and other numerical methods.

Development of Air Cleaning Roll-Filter for Improving IAQ in Subway (도시철도 객실 공기질 개선을 위한 롤필터 개발연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;NanGoong, Seok;Han, Tae-Woo;Cho, Kwan-Hyun;Kim, Tae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.313-319
    • /
    • 2011
  • In a modern society, various type of transportation modes are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day in Seoul. Due to the increased interests on the indoor air quality (IAQ) of underground facilities, public concerns on IAQ of subway system are increasing also. Platform screen door (PSD) recently installed at the whole stations of Seoul subway and tunnel washing-out appeared to be effective in reducing particulate matters in the platform and tunnel. However there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin due to the problem of maintenance cost. Therefore, the object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. In this paper, we focused on the development of particle removing system utilizing a roll-filter for increasing operating time of air filter. The prototype of system was designed and manufactured based on the numerical prediction results. For rollfilter device, 5 candidate filter materials were tested in point of particle collection efficiency and pressure drop. It was found that the electrically charged filter material showed the highest performance among them.

Development of Predictive Growth Model of Listeria monocytogenes Using Mathematical Quantitative Assessment Model (수학적 정량평가모델을 이용한 Listeria monocytogenes의 성장 예측모델의 개발)

  • Moon, Sung-Yang;Woo, Gun-Jo;Shin, Il-Shik
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.194-198
    • /
    • 2005
  • Growth curves of Listeria monocytogenes in modified surimi-based imitation crab (MIC) broth were obtained by measuring cell concentration in MIC broth at different culture conditions [initial cell numbers, $1.0{\times}10^{2},\;1.0{\times}10^{3}\;and\;1.0{\times}10^{4}$, colony forming unit (CFU)/mL; temperature, 15, 20, 25, 37, and $40^{\circ}C$] and applied to Gompertz model to determine microbial growth indicators, maximum specific growth rate constant (k), lag time (LT), and generation time (GT). Maximum specific growth rate of L. monocytogenes increased rapidly with increasing temperature and reached maximum at $37^{\circ}C$, whereas LT and GT decreased with increasing temperature and reached minimum at $37^{\circ}C$. Initial cell number had no effect on k, LT, and GT (p > 0.05). Polynomial and square root models were developed to express combined effects of temperature and initial cell number using Gauss-Newton Algorism. Relative coefficients of experimental k and predicted k of polynomial and square root models were 0.92 and 0.95, respectively, based on response surface model. Results indicate L. monocytogenes growth was mainly affected by temperature and square root model was more effective than polynomial model for growth prediction.

Analysis of Cooling Air Current and Efficiency of Air Conditioning in the Underground Subway Station with Screen-Door Opening and Closing (도시철도 역사 스크린 도어 개폐에 따른 냉방 기류 해석 및 효율 비교 분석)

  • Jang, Yong-Jun;Ryu, Ji-Min;Jung, Ho-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.5
    • /
    • pp.328-335
    • /
    • 2014
  • Numerical prediction methods were applied to investigate the turbulent air currents and air-conditioning efficiency in an underground subway station, and the results compared to experimental data. The Shin-gumho Station($8^{th}$ floor underground and 43.6m in depth) in Seoul was selected for the analysis. The entire station was covered for simulation and the ventilation mode was ordinary. The ventilation diffusers were modeled as 95 square shapes of $0.6m{\times}0.6m$ in the lobby and as 222 square shapes in the platform. Cooling air of $47,316m^3/h$ was supplied and the returned air of $33,980m^3/h$ is exhausted in the lobby and the cooling air of $33,968m^3/h$ is supplied and the returned air of $76,190m^3/h$ was exhausted in the platform which is the same as the experimental data. The cases of the screen-door-closed and open were respectively investigated. A total of 7.5million grids were generated and the whole domain divided into 22 blocks for MPI efficiency of calculation. Large eddy simulation (LES) was applied to solve the momentum and energy equation.

An Approach for the Antarctic Polar Front Detection and an Analysis for itsVariability (남극 극 전선 탐지를 위한 접근법과 변동성에 대한 연구)

  • Park, Jinku;Kim, Hyun-cheol;Hwang, Jihyun;Bae, Dukwon;Jo, Young-Heon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_2
    • /
    • pp.1179-1192
    • /
    • 2018
  • In order to detect the Antarctic Polar Front (PF) among the main fronts in the Southern Ocean, this study is based on the combinations of satellite-based sea surface temperature (SST) and height (SSH) observations. For accurate PF detection, we classified the signals as front or non-front grids based on the Bayesian decision theory from daily SST and SSH datasets, and then spatio-temporal synthesis has been performed to remove primary noises and to supplement geographical connectivity of the front grids. In addition, sea ice and coastal masking were employed in order to remove the noise that still remains even after performing the processes and morphology operations. Finally, we selected only the southernmost grids, which can be considered as fronts and determined as the monthly PF by a linear smoothing spline optimization method. The mean positions of PF in this study are very similar to those of the PFs reported by the previous studies, and it is likely to be well represents PF formation along the bottom topography known as one of the major influences of the PF maintenance. The seasonal variation in the positions of PF is high in the Ross Sea sector (${\sim}180^{\circ}W$), and Australia sector ($120^{\circ}E-140^{\circ}E$), and these variations are quite similar to the previous studies. Therefore, it is expected that the detection approach for the PF position applied in this study and the final composite have a value that can be used in related research to be carried out on the long term time-scale.