• 제목/요약/키워드: mode contribution

검색결과 206건 처리시간 0.027초

Soil and ribbed concrete slab interface modeling using large shear box and 3D FEM

  • Qian, Jian-Gu;Gao, Qian;Xue, Jian-feng;Chen, Hong-Wei;Huang, Mao-Song
    • Geomechanics and Engineering
    • /
    • 제12권2호
    • /
    • pp.295-312
    • /
    • 2017
  • Cast in situ and grouted concrete helical piles with 150-200 mm diameter half cylindrical ribs have become an economical and effective choice in Shanghai, China for uplift piles in deep soft soils. Though this type of pile has been successful used in practice, the reinforcing mechanism and the contribution of the ribs to the total resistance is not clear, and there is no clear guideline for the design of such piles. To study the inclusion of ribs to the contribution of shear resistance, the shear behaviour between silty sand and concrete slabs with parallel ribs at different spacing and angles were tested in a large direct shear box ($600mm{\times}400mm{\times}200mm$). The front panels of the shear box are detachable to observe the soil deformation after the test. The tests were modelled with three-dimensional finite element method in ABAQUS. It was found that, passive zones can be developed ahead of the ribs to form undulated failure surfaces. The shear resistance and failure mode are affected by the ratio of rib spacing to rib diameter. Based on the shape and continuity of the failure zones at the interface, the failure modes at the interface can be classified as "punching", "local" or "general" shear failure respectively. With the inclusion of the ribs, the pull out resistance can increase up to 17%. The optimum rib spacing to rib diameter ratio was found to be around 7 based on the observed experimental results and the numerical modelling.

Punching performance of RC slab-column connections with inner steel truss

  • Shi, Qingxuan;Ma, Ge;Guo, Jiangran;Ma, Chenchen
    • Advances in concrete construction
    • /
    • 제14권3호
    • /
    • pp.195-204
    • /
    • 2022
  • As a brittle failure mode, punching-shear failure can be widely found in traditional RC slab-column connections, which may lead to the entire collapse of a flat plate structure. In this paper, a novel RC slab-column connection with inner steel truss was proposed to enhance the punching strength. In the proposed connection, steel trusses, each of which was composed of four steel angles and a series of steel strips, were pre-assembled at the periphery of the column capital and behaved as transverse reinforcements. With the aim of exploring the punching behavior of this novel RC slab-column connection, a static punching test was conducted on two full-scaled RC slab specimens, and the crack patterns, failure modes, load-deflection and load-strain responses were thoroughly analyzed to explore the contribution of the applied inner steel trusses to the overall punching behavior. The test results indicated that all the test specimens suffered the typical punching-shear failure, and the higher punching strength and initial stiffness could be found in the specimen with inner steel trusses. The numerical models of tested specimens were analyzed in ABAQUS. These models were verified by comparing the results of the tests with the results of the analyzes, and subsequently the sensitivity of the punching capacity to different parameters was studied. Based on the test results, a modified critical shear crack theory, which could take the contribution of the steel trusses into account, was put forward to predict the punching strength of this novel RC slab-column connection, and the calculated results agreed well with the test results.

AMC와 MIMO 선택 기법이 결합된 통신 시스템의 설계 및 성능 분석 (Design and Performance Analysis of a Communication System with AMC and MIMO Mode Selection Scheme)

  • 이정환;윤길상;조인식;서창우;셰를리;황인태
    • 대한전자공학회논문지TC
    • /
    • 제47권3호
    • /
    • pp.22-30
    • /
    • 2010
  • 본 논문은 AMC(Adaptive Modulation and Coding)와 MIMO(Multiple Input Multiple Output)를 결합하여 전송률 및 전송 신뢰도 향상을 가져오는 통신 시스템을 구현한다. 또한 Precoding과 Antenna Subset Selection을 효율적으로 적용하고 MIMO 선택 기법을 결합하여, 최종적으로 AMC와 MIMO 선택 기법이 결합된 통신 시스템을 설계하고 성능을 분석한다. 모의 실험 환경은 안테나 간 상관성이 존재하지 않는 주파수비 선택적 레일리 페이딩 채널을 고려하였으며, 확산인자는 16을 적용하였다. 그 외의 여러 모의 실험 환경은 HSDPA(High Speed Downlink Packet Access) 표준에 근거하여 구성하도록 노력하였다. 본 논문에서 제안한 "AMC와 MIMO 선택 기볍이 결합된 시스템"은 기존의 "AMC와 각 MIMO의 결합 시스템들" 보다 높은 보여주었으며, 열악한 채널 환경에서도 안정적인 전송률을 확보해 주었다. 제안된 시스템은 약 8dB에서 최대 전송률을 나타내었으며, 제안된 시스템과 동일한 최대 전송률올 갖눈 기종의 "AMC와 D-STTD $4{\times}2$ 결합 시스템"과 비교하였을 때 약 6dB 정도 먼저 최대 전송률을 나타냈다. 또한 최대 전송률에 이르기 전까지 거의 모든 SNR(Signal to Noise Ratio)서 기존의 시스템보다 약 2배 정도 높은 전송률을 보였다. 구체적으로 SNR이 2dB인 지점에서 기존의 시스템은 약 2.5Mbps의 전송률을 나타냈으며, 제안된 시스템은 그 2배가 넘는 약 6.4MBps의 전송률을 나타냈다. 또한 SNR이 2dB인 지점에서는 각각 약 7.5Mbps와 15.3Mbps의 전송률을 나타내어 역시 2배에 가까운 차이가 나는 것을 확인할 수 있었다. 제안된 시스템은 AMC 기법을 사용하는 주 목적인 전송률의 향상에 크게 기여하였으며, 특히 평균 전송률의 향상에 효과적임을 확인하였다.

QTW 무인항공기의 종축 비행동역학에 관한 연구 (A Study on Longitudinal Flight Dynamics of a QTW UAV)

  • 정지인;홍성태;김승균;석진영
    • 한국항공우주학회지
    • /
    • 제41권1호
    • /
    • pp.31-39
    • /
    • 2013
  • 본 논문에서는 고정익항공기와 회전익 항공기의 장점을 결합시킨 신개념 복합형 무인항공기인 QTW(Quad Tilt Wing)의 종축 동특성을 연구한 결과를 기술하였다. 설계된 QTW 무인항공기는 Tandem Wing 형상을 가지며 각 주익의 끝단에는 프로펠러를 구동하는 모터를 장착하였다. 비행역학적 분석을 위해 모멘텀 이론을 이용해 추력을 계산하였으며, 틸트 각도에 따른 프로펠러의 Slip stream에 의한 양력과 항력을 고려한 비선형 모델링을 구축하였다. 또한 트림분석을 통해 설계된 비행체가 적절한 비행속도 대비 틸팅각을 가짐을 보여주었으며, 각 트림 점에서의 성분별 힘을 분석하였다. 각 비행 모드의 선형모델 고유치 분석하여 동적 특성을 분석하였으며 고정익모드로 전환됨에 따라 안정한 부분으로 극점이 이동함을 확인하였다.

Retrofit Yield Spectra-a practical device in seismic rehabilitation

  • Thermou, G.E.;Elnashai, A.S.;Pantazopoulou, S.J.
    • Earthquakes and Structures
    • /
    • 제3권2호
    • /
    • pp.141-168
    • /
    • 2012
  • The Retrofit Yield Spectrum (RYS) is a new spectrum-based device that relates seismic demand of a retrofitted structure with the fundamental design parameters of the retrofit. This is obtained from superposition of Yield Point Spectra with design charts that summarize in pertinent spectrum-compatible coordinates the attributes of a number of alternative retrofit scenarios. Therefore, once the requirements for upgrading a given structure have been determined, the RYS enable direct insight of the sensitivity of the seismic response of the upgraded structure to the preliminary design decisions made while establishing the retrofit plan. By virtue of their spectrum-based origin, RYS are derived with reference to a single mode of structural vibration; a primary objective is to control the contribution of this mode in the retrofit design so as to produce a desirable distribution of damage at the ultimate limit state by removing soft storey formations and engaging the maximum number of structural members in deformation, in response to the input motion. Calculations are performed with reference to the yield-point, where secant stiffness is proportional to the flexural strength of reinforced concrete members. Derivation and use of the Retrofit Yield Spectra (RYS) refers to the seismic demand expressed either in terms of spectral acceleration, spectral displacement or interstory drift, at yield of the first storey. A reinforced concrete building that has been tested in full scale to a sequence of simulated earthquake excitations is used in the paper as a demonstration case study to examine the effectiveness of the proposed methodology.

익산지역 가을철 대기 중 호흡성 및 흡입성 먼지입자의 화학조성 (Chemical Composition of Respirable PM2.5 and Inhalable PM10 in Iksan City during Fall, 2004)

  • 강공언
    • 한국환경보건학회지
    • /
    • 제36권1호
    • /
    • pp.61-71
    • /
    • 2010
  • Intensive measurements of airborne respirable $PM_{2.5}$ and inhalable $PM_{2.5}$ were conducted in the downtown area of Iksan city. The $PM_{2.5}$ and $PM_{2.5}$ samples were collected twice a day in the Iksan city of Korea from October 17 to November 1, 2004. The purpose of the study was to determine the inorganic water-soluble components and trace elements of $PM_{2.5}$ and $PM_{2.5}$ in the atmospheric environment and estimate the contribution rate of major chemical components from a mass balance of all measured particulate species. The chemical analysis for PM samples was conducted for water-soluble inorganic ions using ion chromatography and trace elements using PIXE analysis. The mean concentrations of respirable $PM_{2.5}$ and inhalable $PM_{2.5}$ were $51.4{\pm}29.7$ and $79.5{\pm}39.6\;{\mu}g/m^3$, respectively, and the ratio was 0.62. The ion species of $NO_3$, $SO_4^2$, and $NH_4^+$ were abundant in both $PM_{2.5}$ and $PM_{2.5}$. These components predominated in respirable $PM_{2.5}$ fraction, while $Na^+$, $Mg^{2+}$, $Ca^{2+}$ mostly existed in coarse particle mode. Elemental components of S, Cl, K, and Si were abundant in both $PM_{2.5}$ and $PM_{2.5}$. These elements, except for Si, were considered to be emitted from anthropogenic sources, while Si, Al, Fe, Ca existed mainly in coarse particle mode and were considered to be emitted from crustal materials. The averaged mass balance analysis showed that ammonium nitrate, ammonium sulfate, crustal component, and other trace elements were composed of 18.4%, 13.2%, 4.8%, 3.5% for PM2.5 and 17.0%, 11.6%, 13.7%, 4.4% for $PM_{2.5}$, respectively.

앵커의 극한 지지력 변화와 파괴 거동에 관한 연구 (A Study on Variation of Ultimate Pullout Resistance and Failure Behavior for Vertical Plate Anchors in Sands)

  • 장병욱;황명수
    • 한국농공학회지
    • /
    • 제32권4호
    • /
    • pp.71-80
    • /
    • 1990
  • Model tests for the ultimate pullout resistance of anchorages and investigation of failure behaviors in cohesionless soil have been conducted. The factors affecting the anchorage are mostly the geometry of the system, and soil properties of sands. The main conclusions of the experimental work were as follows. 1. The load - displacement relationship can be a form of parabolic curve for all plates. 2. The change in ultimate pullout resistance of anchor is mostly affected by embedment ratio and size of anchor, and influenced to a lesser degree by its shape. 3. Critical embedment ratio which is defined as the failure mode changes from shallow to deep mode is increased with increasing height of anchor. 4. For a constant anchor height, as the width of anchor increases the ultimate pullout resistance also increases. However, considering the efficiency of anchor for unit area, width of anchor does not appear to have any sigrnificant contribution on increasing anchor city. 5. Anchor capacity has a linear relation to sand density for any given section and the rate of change increases as the section increases. Critical depth determining the failure patterns of anchor is decreased with a decrease of sand density. 6. With increasing inclination angle, size of anchor, and decreasing embedment ratio, the ultimate pullout resistance of anchor under inclined loading is significantly decreased. 7. The ultimate pullout resistance of double anchor, a method of improving single of anchor capacity, is influenced by the center - to - center spacing adjacent anchors. It is also found that tandem and parallel anchor rigging arrangements decrease the anchor system capacity to less than twice the single anchor capacity due to anchor interference.

  • PDF

태양활동 긴 주기와 기후변화의 연관성 분석 (Long Term Variability of the Sun and Climate Change)

  • 조일현;장헌영
    • Journal of Astronomy and Space Sciences
    • /
    • 제25권4호
    • /
    • pp.395-404
    • /
    • 2008
  • 태양활동프록시(proxies)와 지구연평균 기온아노말리 시계열을 이용하여 기후변화에서 태양활동신호를 찾아보았다. 이를 위해 Lomb & Scargle의 피어리드그램(Periodgram)을 이용하여 태양활동프록시와 기온아노말리 시계열을 주기분석하였다. 또한 EMD(Empirical Mode Decomposition)과 MODWR MRA(Maxial Overlap Discrete Wavelet Transform Multi Resolution Analysis)를 적용하여 두 시계열을 성분분해하고 이들 중 비슷한 주기의 특성을 보이는 성분을 비교하였다. 태양활동프록시는 짧의 주기의 파워가 긴 주기의 파워에 비해서 큰 반면 기온아노말리는 긴 주기에서 더 큰 파워를 보였다 EMD에 의한 성분분해 결과는 약40년보다 긴 주기성을 갖는 성분을 분해해 낼 수 없었지만 잔차 성분은 비교할 수 있었다. MRA에 의한 성분분해를 통해 지구연평균 기온아노말리 시계열에서 태양활동의 변화에 의한 신호를 찾아내었다. 1960년부터 2007년까지 기온상승에 대한 태양의 기여도는 39%로 계산되었다. 기후민감성은 출력신호의 진폭에만 관계하여 기후시스템이 간단한 2계미분방정식으로 근사될 수 있는 가능성에 대해 토의하였다.

A Fast CU Size Decision Optimal Algorithm Based on Neighborhood Prediction for HEVC

  • Wang, Jianhua;Wang, Haozhan;Xu, Fujian;Liu, Jun;Cheng, Lianglun
    • Journal of Information Processing Systems
    • /
    • 제16권4호
    • /
    • pp.959-974
    • /
    • 2020
  • High efficiency video coding (HEVC) employs quadtree coding tree unit (CTU) structure to improve its coding efficiency, but at the same time, it also requires a very high computational complexity due to its exhaustive search processes for an optimal coding unit (CU) partition. With the aim of solving the problem, a fast CU size decision optimal algorithm based on neighborhood prediction is presented for HEVC in this paper. The contribution of this paper lies in the fact that we successfully use the partition information of neighborhood CUs in different depth to quickly determine the optimal partition mode for the current CU by neighborhood prediction technology, which can save much computational complexity for HEVC with negligible RD-rate (rate-distortion rate) performance loss. Specifically, in our scheme, we use the partition information of left, up, and left-up CUs to quickly predict the optimal partition mode for the current CU by neighborhood prediction technology, as a result, our proposed algorithm can effectively solve the problem above by reducing many unnecessary prediction and partition operations for HEVC. The simulation results show that our proposed fast CU size decision algorithm based on neighborhood prediction in this paper can reduce about 19.0% coding time, and only increase 0.102% BD-rate (Bjontegaard delta rate) compared with the standard reference software of HM16.1, thus improving the coding performance of HEVC.

ATM에서 가상 스위치를 이용한 흐름 제어 방식의 성능 분석 (Performance Analysis of Flow Control Method Using Virtual Switchs on ATM)

  • 조미령;양성현;이상훈
    • 한국컴퓨터산업학회논문지
    • /
    • 제3권1호
    • /
    • pp.85-94
    • /
    • 2002
  • ATM(Asychronous Transfer Mode) 표준에서 제안된 EMRCA(Explicit Max_min Rate Control Algorithm) 스위치 방식은 ATM 네트워크에서 ABR(Available Bit Rate) 서비스 트래픽을 제어한다. ATM 네트워크의 ABR 서비스 분류는 다양한 링크 용량에 적용하기 위하여 피드백 제어 방식을 사용한다. VS/VD(Virtual Source/Virtual Destination) 기법은 다른 종단간 ABR 제어 루프를 격리된 루프들로부터 분리할 수 있도록 해준다. 피드백 지연과 내부적으로 폐쇄된 구간을 갖는 ABR 트래픽 제어는 처리량, 지연 그리고 지터 등을 고려한 ABR 접속에 있어서 보다 나은 성능과 QoS(Quality of Service)를 제공한다. 본 논문은 ABR VS/VD 흐름 제어 방식에 관한 연구이다. 매개변수를 정확하게 선택하고 시스템의 안정성과 같은 성능을 평가하는 수단을 제공하기 위하여 선형 제어 이론을 사용하여 모델링 하였다. 성능 개선의 목적은 높은 링크 이용율과 공정한 대역폭 분배 그리고 안정된 동작등이며 이는 이산 사건 시뮬레이션을 하였다. 본 논문에서는 VS/VD 스위치의 특수한 레이아웃에 맞춘 ABR 흐름 제어 방식의 설계에 선형 제어 이론을 사용한 것이며 시뮬레이션을 하여 기존의 폭주 제어 방식보다 우수함을 보였다.

  • PDF