• Title/Summary/Keyword: modal filter

Search Result 70, Processing Time 0.023 seconds

Robustness of Independent Modal Space Control for Parameter and Modal Filter Errors (파라메터오차 및 모달필터오차에 대한 독립모달공간 제어기법의 강인성 해석)

  • Hwang, Jai-Hyuk;Kim, Joon-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.11
    • /
    • pp.3549-3559
    • /
    • 1996
  • In this study, the effect of parameter and modal filter errors on the vibration control characteristics of flexible structures is analyzed for IMSC ( Independent Modal Space Control). If the control force is designed on the basis of the mathematical model with the parameter and modal filter errors, the closed-loop performance of the vibration control system will be degraded depending on the magnitude of the errors. An asymptotic stability condition of the system with parameter and modal filter errors has more significant effect on the stability condition of the system with parameter and modal filter errors has been drived using Lyapunov approach. It has been found that modal filter error has more significant effect on the stability of closed-loop system than parameter error does. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator thchniques.

Sensor Placement in Structural Vibration Control For the Performance of Modal Filter (모달필터 성능을 고려한 센서의 최적위치)

  • 황재혁;김준수;백승호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.308-315
    • /
    • 1997
  • In this study, the effect of modal filter error on the vibration control characteristics of flexible structures is analyzed for IMSC(Independent Modal Space Control), and optimal sensor placement in the structural vibration control with consideration of performance of modal filter has been studied. An Lyapunov asymptotic stability condition has been derived, which depends on the magnitude of the modal filter errors. The extent of the response deviation of the closed-loop system is also derived and evaluated using operator techniques. A sensor placement technique has also been suggested to maximize the performance of the modal filter. It has been found by a series of simulation that the suggested sensor placement technique is very effective on the determination of the number and placement of sensors of modal filter in the structural vibration control.

  • PDF

The application of modal filters for damage detection

  • Mendrok, Krzysztof;Uhl, Tadeusz
    • Smart Structures and Systems
    • /
    • v.6 no.2
    • /
    • pp.115-133
    • /
    • 2010
  • A modal filter is a tool used to extract the modal coordinates of each individual mode from a system's output. This is achieved by mapping the response vector from the physical space to the modal space. It decomposes the system's responses into modal coordinates, and thus, on the output of the filter, the frequency response with only one peak corresponding to the natural frequency to which the filter was tuned can be obtained. As was shown in the paper (Deraemecker and Preumont 2006), structural modification (e.g. a drop in stiffness or mass due to damage) causes the appearance of spurious peaks on the output of the modal filter. A modal filter is, therefore, a great indicator of damage detection, with such advantages as low computational effort due to data reduction, ease of automation and lack of sensitivity to environmental changes. This paper presents the application of modal filters for the detection of stiffness changes. Two experiments were conducted: the first one using the simulation data obtained from the numerical 7DOF model, and the second one on the experimental data from a laboratory stand in 4 states of damage.

Indirect Input Identification by Modal Filter Technique (모드필터방법에 의한 간접적 입력규명)

  • 김영렬;김광준
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.377-386
    • /
    • 1999
  • This paper is a study on model method for estimating system inputs from vibration responses, which is one of indirect input identification methods in frequency domain. The method has advantages over direct inverse method especially when points of operational inputs are inaccessible so that artificial excitation forces cannot be applied to obtain frequency response functions of the complete system. Procedures of extended modal model method are proposed and checked by numerical experiment. Mechanisms of error propagation, i.e., how errors in modal parameters such as poles nad mode shape vectors affect estimation of the input forces, are illustrated. Then, in order to counteract the error propagation, discrete modal filter approach is taken in this paper to compute the inversion of modal matrix in which the most serious errors seem to be generated. Further, a Reduced form of Modified Reciprocal Modal Vector(RMRMV) is proposed for estimating multiple inputs. It is shown to have smaller orthogonality error than MRMV.

  • PDF

Active control for Seismic Response Reduction using Modal-fuzzy Approach (모달 퍼지 이론을 이용한 지진하중을 받는 구조물의 능동제어)

  • Choi, Kang-Min;Cho, Sang-Won;Oh, Ju-Won;Lee, In-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.409-416
    • /
    • 2004
  • An active modal-fuzzy control method using hydraulic actuators is presented for seismic response reduction. In the proposed control system, a new fuzzy controller designed in the modal space produces the desired active control force. This type controller has all advantages of the fuzzy control algorithm and modal approach. Since it is very difficult to select input variables used in fuzzy controller among an amount of state variables in the active fuzzy control system the presented algorithm adopts the modal control algorithm which is able to consider more easily information of all state variables in civil structures that are usually dominated by first few modes. In other words, all information of the whole structure can be considered in the control algorithm evaluated to reduce seismic responses and it can be efficient for especially civil structures. In addition, the presented algorithm is expected to magnify utility and performance caused by efficiency that the fuzzy algorithm can handle complex model more easily. An active modal-fuzzy control scheme is applied together with a Kalman filter and a low-pass filter to be applicable to real civil structures. A Kalman filter is considered to estimate modal states and a low-pass filter was used to eliminate spillover problem. The results of the numerical simulations far a wide amplitude range o f loading conditions and for historic earthquakes having various frequency components show that the proposed active modal-fuzzy control system can be beneficial in reducing seismic responses of civil structures.

  • PDF

Active control for Seismic Response Reduction using Modal-fuzzy Approach (모달 퍼지 이론을 이용한 지진하중을 받는 구조물의 능동제어)

  • Choi, Kang-Min;Park, Kyu-Sik;Kim, Chun-Ho;Lee, In-Won
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.513-520
    • /
    • 2005
  • An active modal-fuzzy control method using hydraulic actuators is presented for seismic response reduction. In the proposed control system, a new fuzzy controller designed in the modal space produces the desired active control force. This type controller has all advantages of the fuzzy control algorithm and modal approach. Since it is very difficult to select input variables used in fuzzy controller among an amount of state variables in the active fuzzy control system, the presented algorithm adopts the modal control algorithm which is able to consider more easily information of all state variables in civil structures that are usually dominated by first few modes. In other words, all information of the whole structure can be considered in the control algorithm evaluated to reduce seismic responses and it can be efficient for especially civil structures. In addition, the presented algorithm is expected to magnify utility and performance caused by efficiency that the fuzzy algorithm can handle complex model more easily. An active modal-fuzzy control scheme is applied together with a Kalman filter and a low-pass filter to be applicable to real civil structures. A Kalman filter is considered to estimate modal states and a low-pass filter was used to eliminate spillover problem. The results of the numerical simulations for a wide amplitude range of loading conditions show that the proposed active modal-fuzzy control system can be beneficial in reducing seismic responses of civil structures.

  • PDF

Study on Birefringence Effect Of Single-Mode Fiber on Output Spectra of High-Order Fiber Comb Filter Based on Polarization-Diversity Loop Configuration (단일 모드 광섬유의 복굴절이 편광상이 배치구조 기반 고차 광섬유 빗살 필터의 출력 스펙트럼에 미치는 영향에 대한 고찰)

  • Kim, Young-Ho;Lee, Yong-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.6
    • /
    • pp.8-15
    • /
    • 2012
  • In this paper, we investigated possible optical parameters causing deviation of experimentally observed output spectra from theoretically predicted results in a high-order fiber comb filter based on a polarization-diversity loop configuration. They include wavelength dependency of half-wave plates (HWPs) inserted in the filter for wavelength switching and the modal birefringence of single-mode fibers (SMFs) with which optical components comprising the filter are connected. In order to consider the effect of the modal birefringence of the SMF on a filter performance, it is modeled as a low birefringence fiber with an arbitrary orientation angle and birefringence. It is found from the simulation results that the modal birefringence of SMFs strongly affects the spectral characteristics of the filter and decreases the extinction ratio of the filter, compared with the wavelength dependency of HWPs. In particular, it is also confirmed that the spectral deviation and asymmetric distortions of side-lobes in narrow band transmission spectra result mainly from the modal birefringence of SMFs.

An application of operational deflection shapes and spatial filtration for damage detection

  • Mendrok, Krzysztof;Wojcicki, Jeremi;Uhl, Tadeusz
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1049-1068
    • /
    • 2015
  • In the paper, the authors propose the application of operational deflection shapes (ODS) for the detection of structural changes in technical objects. The ODS matrix is used to formulate the spatial filter that is further used for damage detection as a classical modal filter (Meirovitch and Baruh 1982, Zhang et al. 1990). The advantage of the approach lies in the fact that no modal analysis is required, even on the reference spatial filter formulation and other components apart from structural ones can be filtered (e.g. harmonics of rotational velocity). The proposed methodology was tested experimentally on a laboratory stand, a frame-like structure, excited from two sources: an impact hammer, which provided a wide-band excitation of all modes, and an electro-dynamic shaker, which simulated a harmonic component in the output spectra. The damage detection capabilities of the proposed method were tested by changing the structural properties of the model and comparing the results with the original ones. The quantitative assessment of damage was performed by employing a damage index (DI) calculation. Comparison of the output of the ODS filter and the classical modal filter is also presented and analyzed in the paper. The closing section of the paper describes the verification of the method on a real structure - a road viaduct.

Torsional Damping Estimation of a Segmented Hull Model with Modal Coupling (모드 연성을 수반하는 분할 모형의 비틀림 감쇠비 추정)

  • Kim, Yooil;Park, Sung-Gun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.6
    • /
    • pp.482-493
    • /
    • 2016
  • The identification of modal damping of a segmented hull model with torsional response is difficult task due to the coupling of modal response. This is because the 1st and 2nd torsional vibration modes are closely spaced in frequency domain leading to the situation that the modal decomposition is difficult to achieve by simple band-pass filter. Present study applied several different modal decomposition methods to derive the damping ratio of different modes. The modal decomposition methods considered in this study are simple band-pass filter, Hilbert vibration decomposition, Wavelet transform and proper orthogonal decomposition. Coupled free decay signal obtained from the torsional hammering test on a segmented hull model was processed with four different methods and the derived damping ratios were compared with each other. Discussions also have been made on the pros and cons of the different methodologies.

A Modal Identification of Self-Adjoint Distributed Parameter Systems Using Spatial Filter (공간함수 필터를 이용한 자기수반계의 모달판정)

  • 강수준
    • Journal of KSNVE
    • /
    • v.4 no.1
    • /
    • pp.51-57
    • /
    • 1994
  • The objective of this research is to introduce a method of modal identification for self-adjoint distributed parameter systems using Spatial Fiter. To minimize the spillover effects which come from using the finite discrete sensors by means of discrete measurements, a new mechanism, namely spatial filter which is main subject in this research, is introduced for extracting modal coordinates from sensors' output. As an illustration of the proposed method, two simple numerical examples are also examined.

  • PDF