• Title/Summary/Keyword: mock circulation

Search Result 36, Processing Time 0.025 seconds

인조신경망을 이용한 좌심실보조장치의 동적 모델링

  • 김훈모
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.346-350
    • /
    • 1996
  • This paper presents a Neural Network Identification (NNI) method for modeling of highly complicated nonlinear and time varing human system with a pneumatically driven mock circulation system of Left Ventricular Assist Device(LVD). This system consists of electronic circuits and pneumatic driving circuits. The initation of systole and the pumping duration can be determined by the computer program. The line pressure from a pressure transducer inserted in the pneumatic line was recorded. System modeling is completed using the adaptively trained backpropagation learning algorithms with input variables, Heart Rate(HR), Systole-Diastole Rate(SDR), which can vary state of system, and preload, afterload, which indicate the systemic dynamic characteristics and output parameters are preload, afterload.

  • PDF

A study on the development of motor-driven artificial heart and its control (인공심장의 자동제어)

  • 민병구;김희찬;권성일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.643-647
    • /
    • 1986
  • A new type of motor-driven Total Artificial Heart (TAH) system with rolling-ball mechanism has been developed. To test its performance as a Left Ventricular Assist Device (LVAD), LVAD is controlled to bypass blood for impaired heart triggered by the R-wave in ECG. Results of the test with a Mock Circulation System (MCS) and an animal experiment with a dog are also included. More powerful system using a brushless DC motor has been developed and its control scheme is represented.

  • PDF

Design and Analysis of Motor-Driven Artificial Heart ( II );Analysis (모터 구동형 인공심장의 설계 및 해석(II) 해석)

  • 천길정;한동철;민병구
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.3
    • /
    • pp.855-868
    • /
    • 1991
  • 본 연구에서는 위에서 언급한바와 같은 제반사항들에 대해 이론적인 해석을 행하고, 그 결과를 이용하여 설계된 모델이 생체내에 이식될 수 있는 가능성의 여부를 판단하며 생체내에 이식 되었을 때의 성능과 생체에 미치는 영향등을 예측하고자 한다.

A Study of the Acoustical Properties of the Mechanical Heart Valve Using MUSIC (MUSIC을 이용한 기계식 심장 판막의 음향 신호 특성 연구)

  • Yi S. W.;Choi M. J.;Min B. G.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.131-134
    • /
    • 1999
  • This paper considers the acoustical characteristics of the mechanical valve employed in the Korean type Artificial Heart. $Bj\"{o}rk-Shiley$ tilting disc valve was chosen for the study and acoustic measurements were performed for the artificial heart operated in a mock circulation system as well as implanted to an animal as a Bi Ventricular Assist Device (BVAD). In the mock system, three different conditions of the valve were examined which were normal, damaged (torn off), pseudothrombus attached. Microphone measurements for the BVAD were carried out at a regular time interval for 5 days after the implantation operation. Of the recorded acoustic emissions from the artificial heart, click sounds mainly originated from the valves were further analyzed using Multiple Signal Classification (MUSIC) for estimating their spectral properties. It was shown that the spectral peaks below 4 kHz and the optimal order number for MUSIC, equivalent to the number of the spectral component, might be the key parameters which were highly correlated to the physiological states of the valve like the mechanical damage of the valve or the formation of thrombus on the valves.

  • PDF

Evaluation of Pneumatic Left Ventricular Assist Device for Animal Experiment (동물실험을 통한 공압식 좌심실보조장치의 평가)

  • Lee, H.S.;Oh, H.J.;Lee, S.H.;Kim, S.H.;Seo, P.W.;Park, S.S.;Rhee, K.H.;Ahn, H.;Hwang, S.O.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.235-236
    • /
    • 1998
  • The purpose of this paper is to develop diaphragm type pneumatic Left Ventricular Assist Device(LVAD) for clinical application and to evaluate its performance through the mock circulation and animal experiment. The blood housing and diaphragm are made by polyurethane. The relations of cardiac output us. beat rate and cardiac output vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. We performed animal experiment and 4 animals survived more than 24hrs. As a result, the hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

Development and Evaluation of Pneumatic Ventricular Assist Device (공압식 심실보조장치의 개발 및 평가)

  • Lee, S.H.;Park, I.T.;Kim, S.H.;Han, D.S.;Lee, H.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.247-250
    • /
    • 1995
  • The purpose of this paper is to develop diaphragm-type pneumatic ventricular assist device(VAD) for clinical application and to evaluate its performance through the mock circulation system. The blood housing and diaphragm are made by coating pellethane on the metallic mold and the back plate is made by machining process. The relations of cardiac output(CO) vs. beat rate and CO vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. As a result, the volume of blood pump is 70 ml, maximum CO is 5 L/min and CO has a close relation to the input resistance of blood pump. The hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

Hydraulic Design Optimization and Performance Analysis of a Centrifugal Blood Pump (원심형 혈액펌프의 최적화 수력설계 및 성능해석)

  • Park Moo Ryong;Yoo Seong Yeon;Oh Hyoung Woo;Yoon Eui Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.87-94
    • /
    • 2006
  • This paper presents the hydrodynamic design and performance analysis method for a miniaturized centrifugal blood pump using three-dimensional computational fluid dynamics (CFD) code. In order to obtain the hydraulically high efficient configuration of a miniaturized centrifugal blood pump for cardiopulmonary circulation, a well-established commercial CFD code was incorporated considering detailed flow dynamic phenomena in the blood pump system. A prototype of centrifugal blood pump developed by the present design and analysis method has been tested in the mock circulatory system. Predicted results by the CFD code agree very well with in vitro hydraulic performance data for a centrifugal blood pump over the entire operating conditions. Preliminary in vivo animal testing has also been conducted to demonstrate the hemodynamic feasibility for use of centrifugal blood pump as a mechanical circulatory support. A miniaturized centrifugal blood pump developed by the hydraulic design optimization and performance prediction method presented herein shows the possibility of a good candidate for intra and extracorporeal cardiopulmonary circulation pump in the near future.

Development of the Rolling-cylinder Type Motor-driven Total Artificial Heart System

  • Min, Byoung-G.;Kim, Hee-C.;Cheon, Gill-J.
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.2
    • /
    • pp.161-170
    • /
    • 1987
  • A new type of motor-driven total artificial heart system with a rolloing-cylinder mechanism has been developed. The prototype system consists of a brushless DC motor inside of a rolling-cylinder, two arc shaped pusher-plate s, and two ventricles of smooth, seamless polyurethane sacs. The motor-driven pump has the advantages of being portable and quiet compared to the present air-driven pump. It can also be controlled more accurately. This rolling-cylinder type electromechanical pump has several structural advantages including small size and weight, as compared to other research groups' motor-driven pumps. The results of mock circulation tests confirm sufficient pump output capacity(cardiac output . 9 L/min, at aortic pressure'120mmHg, with heart rate . 120 BPM) for animal implantation of our prototype system.

  • PDF

Automatic cardiac output control algorithm for total artificial heart by current waveform analysis (전류파형분석에 의한 완전이식 인공심장의 심박출량 자동제어 알고리즘)

  • 최원우;김희찬;민병구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.383-391
    • /
    • 1993
  • In this paper, a new automatic cardiac output control algorithm without any pressure sensors for the motor-driven electromechanical total artificial heart(TAH) was developed using motor current information. In the previous studies, many transducers were utilized to obtain informations of hemodynamic states for the automatic cardiac output control. But. such automatic control with sensors has some problems. To solve these problems, I proposed a new "sensorless" automatic cardiac output control algorithm providing the adequate cardiac output to the time-varying physiological demand without right atrial collapse. In-vitro tests were performed to evaluate the performance of a new algorithm and it satisfied the basic three requirements on the pump output response through the mock circulation tests.

  • PDF

Development of totally implantable total artificial heart controller

  • Choi, Won-Woo;Lee, Sang-hoon;Lee, Woo-Cheol;Min, Byoung-Gu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.758-761
    • /
    • 1991
  • Using one chip microcontroller 87Cl96 (On chip EPROM type) and EPLD (Erasable & Programable Logic Device), an implantable control system to drive pendulum type electromechanical total artificial heart was developed. This control system consists of 4 parts, main management system, motor driver with power regulator, state monitoring system and communication part. The main system has the functions for speed detection, PI(proportional and integration) control, PWM generation, communication and analog data processor. Two kinds of power system were used and separated by 8 photo coupler arrays to improve the system stability. The performances of each compartments were compared with our previous z80 microprocessor based control system and good correspondences was shown. Logic power consumption was reduced to a one third of our previous controller. Using mock circulation tests, the overall performances of control system are evaluated.

  • PDF