• 제목/요약/키워드: mobile linear system

Search Result 225, Processing Time 0.02 seconds

3D Displays: Development and Validation of Prediction Function of Object Size Perception as a Function of Depth (3D 디스플레이: 깊이에 따른 대상의 크기지각 예측함수 개발 및 타당화)

  • Shin, Yoon-Ho;Li, Hyung-Chul O.;Kim, Shin-Woo
    • Journal of Broadcast Engineering
    • /
    • v.17 no.2
    • /
    • pp.400-410
    • /
    • 2012
  • In recent years, 3D displays are used in many media including 3D movies, TV, mobile phones, and PC games. Although 3D displays provide realistic viewing experience as compared with 2D displays, they also carry issues such as visual fatigue or size distortion. Focusing on the latter, we developed prediction function of object size perception as a function of object depth in 3D display. In Experiment 1, subjects observed 3D square of a fixed size of varying depth, and manipulated 2D square to make it as large as the 3D square. Conversely, in Experiment 2, subjects observed 2D square of a fixed size, and manipulated 3D square of varying depth to make it as large as the 2D square. In both Experiments 1 and 2, we found that size perception of 3D square linearly changed depending on depth of the square, and the linear relationship between depth and size was identical in both experiments. The predictive regression function, which predicts object size perception based on object depth, obtained in this research will be very useful in the creation of 3D media contents.

A Study on the Propagation Prediction Model of Wireless Communication in an Urban Area (도심지 무선통신의 전파예측모델에 관한 연구)

  • 정성한;배성수;오영환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12A
    • /
    • pp.1883-1890
    • /
    • 1999
  • Wireless communication in an urban area, the accurate prediction of wave propagation characteristics are very important to determine communication service areas, select optimal base-stations, and design cells, etc. The CCIR model is a propagation prediction model using a shadowing by the buildings in an urban area. This model represent the shadowing rate by the means of the effect of shadowing between base-station and mobile unit in a shaped linear plane. But, This one occurred a lot of prediction error because it did not consider that density area by the buildings and terrain configurations by the hill and mountain on Line-Of-Sight. In this thesis, an improved propagation prediction model is proposed to reduce prediction error. We presents a new equation, which is using the SAS. This equation is associated with the shadow height by the buildings that considers the topology and the number of blocks that can affect the building shadow in the Line-Of-Sight. We measure the received electrical field level of base-station that high density area, medium density area, and low density area, and then compare and analysis the result to prediction of CCIR model and proposed model. The result compared with the measurement, the proposed model has the improvement of 9.71dB in a high density area, 9.66dB in a medium density area, and 4.02dB in a low density area better than the CCIR model. The result compared with the measurement, the proposed model has the improvement of 9.71dB in a high density area, 9.66dB in a medium density area, and 4.02dB in a low density area better than the CCIR model.

  • PDF

HPLC Analysis and Pharmacokinetics of KAL-1120, a Novel Anti-inflammation Agent, in Rats (흰쥐에서 항염증제 후보물질 KAL-1120의 HPLC 분석 및 약물동태)

  • Shin, Dae-Hwan;Lee, Jung-Yeol;Park, Seong-Hyeok;Lee, Gyeong-Bok;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of N-(-4-Chlorophenyl)-6-hydroxy-7-methoxy-2-chromanecarboxamide (KAL-1120), a novel anti-inflammation agent, in the rat plasma. The method was applied to analyze the compound in the biological fluids such as bile, urine and tissue homogenates. After liquid-liquid extraction, the compound was analyzed on an HPLC system with ultraviolet detection at 275 nm. HPLC was carried out using reversed-phase isocratic elution with a $C_{18}$ column, a mobile phase of a mixture of acetonitril (40 v/v%) at a flow rate of 1.0 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma was linear over the concentration range of 0.05-50 ${\mu}g$/mL. The intra- and inter-day assay accuracies of this method ranged from 0.06% to 9.33% of normal values and the precision did not exceed 6.28% of relative standard deviation. The plasma concentration of KAL-1120 decreased to below the quantifiable limit at 1.5 hr after the i.v. bolus administration of 2-10 mg/kg to rats ($t_{1/2,({\alpha})}$ and $t_{1/2,({\beta})$ of 2.15 and 26.7 min at a dose of 2 mg/kg, 3.91 and 33.0 min at a dose of 10 mg/kg, respectively). The steady-state volume of distribution ($V_{dss}$) and the total body clearance ($CL_t$) were not significantly altered in rats given doses from 2 to 10 mg/kg. Of the various tissues tested, KAL-1120 was mainly distributed in the lung and heart after i.v. bolus administration. KAL-1120 was detected in the bile by 30 min after its i.v. bolus administration. However, the concentration in the urine after i.v. bolus administration became too low to measure, suggesting that KAL-1120 is mostly excreted in the bile. In conclusion, this analytical method was suitable for the preclinical pharmacokinetic studies of KAL-1120 in rats.

A Study of the Retention Mechanism of the Monosubstituted Benzenes in Reversed-phase Liquid Chromatography (II) (역상 액체크로마토그래피에서 벤젠 일치환체들의 머무름 메카니즘에 관한 연구 (제 2 보))

  • Lee, Dai-Woon;Choi, Yong-Wook;Lee, Won
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.135-143
    • /
    • 1988
  • The correlations between chromatographic parameters of monosubstituted benzenes and several physical parameters in reversed phase liquid chromatography were studied. The relationships between retention data and polarity index were investigated by plotting $log(log k'_S/k'_B)$ vs. $P'_S/P'_B$ which were relative retention and relative polarity index of monosubstituted benzenes with respect to benzene, respectively. The linear relationship between relative retention and polarity index was observed for the monosubstituted benzenes having polar group, while in case of those having nonpolar group, the good linearity was observed by combination with relative molecular weight i.e. $(P'_S/P'_B)/(MW_S/MW_B)$. Multivariant regression analysis, $a(P'_S/P'_B)+b(MW_S/MW_B)$+c did not give significantly better correlations compared to single variant analysis, $a[(P'_S/P'_B)/(MW_S/MW_B)]$+c, but multiple stepwise regression analysis was recommended when several physical parameters simultaneously were chosen. The best correlation between retention data for monosubstituted benzenes taken from the literature and substituent constant(${\pi}$), derived from hydrophobic parameter and the first order molecular connectivity index$(^1{\chi}^{\nu})$, was established for methanol/water mobile phase system. The larger the surface coverage of the stationary phase, the higher was the correlation coefficient between these two parameters and retention data.

  • PDF

Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry (시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석)

  • Heo, Bo-Reum;Kwon, NamHee;Kim, Jin Young
    • Analytical Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.161-170
    • /
    • 2018
  • The epidemic of disorders associated with synthetic stimulants, such as methamphetamine (MA) and amphetamine (AP), is a health, social, legal, and financial problem. Owing to the high potential of their abuse and addiction, reliable analytical methods are required to detect and identify MA, AP, and their metabolites in biological samples. Thus, a dilute-and-shoot liquid chromatography-tandem mass spectrophotometry (LC-MS/MS) was developed for simultaneous determination of MA, 4-hydroxymethamphetamine (4HMA), AP, and 4-hydroxyamphetamine (4HA) in urine. Urine sample ($100{\mu}L$) was mixed with $50{\mu}L$ of mobile phase consisting of 0.4 % formic acid and methanol and $50{\mu}L$ of working internal-standard solution. Aliquots of $8{\mu}L$ diluted urine was injected into the LC-MS/MS system. For all analytes, chromatographic separation was performed using a C18 reversed-phase column with gradient elution and a total run time of 5 min. The identification and quantification were performed by multiple reaction monitoring (MRM). Linear least-squares regression was conducted to generate a calibration curve, with $1/x^2$ as the weighting factor. The linear ranges were 2.0-200, 1.0-800, and 10-2500 ng/mL for 4HA and 4HMA, AP, and MA, respectively. The inter- and intraday precisions were within 6.6 %, whereas the inter- and intraday accuracies ranged from -14.9 to 11.3 %. The low limits of quantification were 2.0 ng/mL (4HA and 4HMA), 1.0 ng/mL (AP), and 10 ng/mL (MA). The proposed method exhibited satisfactory selectivity, dilution integrity, matrix effect, and stability, which are required for validation. Moreover, the purification efficiency of high-speed centrifugation was clearly higher than 6-15 % for QC samples (n=5), which was higher than that of the membrane-filtration method. The applicability of the proposed method was tested by forensic analysis of urine samples from drug abusers.