• Title/Summary/Keyword: mmWave

Search Result 1,012, Processing Time 0.025 seconds

Time-Slotted Scheduling Schemes for Multi-hop Concurrent Transmission in WPANs with Directional Antenna

  • Bilal, Muhammad;Kang, Moonsoo;Shah, Sayed Chhattan;Kang, Shin-Gak
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.374-384
    • /
    • 2014
  • To achieve high-speed (giga-bit) connectivity for short-range wireless multimedia applications, the millimeter-wave (mmWave) wireless personal area networks with directional antennas are gaining increased interest. Due to the use of directional antennas and mmWave communications, the probability of non-interfering transmissions increases in a localized region. Network throughput can be increased immensely by the concurrent time allocation of non-interfering transmissions. The problem of finding optimum time allocation for concurrent transmissions is an NP-hard problem. In this paper, we propose two enhanced versions of previously proposed multi-hop concurrent transmission (MHCT) schemes. To increase network capacity, the proposed schemes efficiently make use of the free holes in the time-allocation map of the MHCT scheme; thus, making it more compact.

Millimeter wave 기반 V2I, V2V 통신 기술 연구 동향 및 발전 방향

  • Jeong, Seung-Jae;Gang, Jun-Hyeok
    • Information and Communications Magazine
    • /
    • v.34 no.6
    • /
    • pp.3-10
    • /
    • 2017
  • 최근 운전자의 편의성과 안전성 향상을 위한 커넥티드 카 및 자율주행 차량에 대한 관심과 연구가 집중되고 있다. 이러한 커넥티드 카와 자율주행 차량의 경우 대용량의 멀티미디어 전송 및 센서 데이터 공유 등 다양한 서비스를 위해 높은 전송용량과 신뢰성을 보장할 수 있는 vehicle-to-vehicle (V2V) 통신과 vehicle-to- infrastructure (V2I) 통신에 대한 기본적인 연구와 구현이 필수적이다. 이러한 요구사항을 만족시키기 위해서 최근 mmWave 기반의 V2V, V2I에 대한 연구가 큰 주목을 받고 있다. 본고에서는 mmWave 대역 V2V 및 V2I 기술의 필요성과 채널에 관련된 기존 연구를 살펴보고, 이를 기반으로 현재까지 연구된 mmWave 대역 V2V, V2I 관련 연구에 대해 살펴보고자 한다. 또한 기존 연구의 한계점을 확인하고, 향후 연구방향과 주제에 대해 논의하고자 한다.

Design Method for the Millimeter Wave Corrugated Feed Horn Antenna (mm파 컬러게이트 휘드 혼 안테나의 설계법)

  • Son, Tae-Ho;Park, Young-Tae;Han, Seog-Tae
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.487-491
    • /
    • 2003
  • Design procedure of corrugated horn antenna for mm-wave frequency range is presented, and hybrid condition in horn is calculated. Balanced hybrid mode should be converted in the horn from TE11 mode by the proper corrugation dimensions which size are available to be fabricated under the mm-wave short wavelength condition. In this paper, corrugate profiles which satisfy both hybrid condition and fabrication possibility are obtained.. By cylindrical mode theory, the electromagnetic fields both inside hem and corrugation are delivered. Propagation characteristics in hem is calculated by the mode impedance matching method with boundary conditions, and radiation fields are obtained by the Kirchhoff-Hyugen principle to the hem aperture fields. A mm-wave corrugated horn operates on 85 - 115GHz is designed and fabricated, and results of measurement are also shown.

  • PDF

The Modulation of Currents and Waves near the Korean Marginal seas computed by using MM5/KMA and WAVEWATHC-III model

  • Seo, Jang-Won;Chang, You-Soon
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.37-42
    • /
    • 2003
  • We have analyzed the characteristics of the sea surface winds and wind waves near the Korean marginal seas on the basis of prediction results of the sea surface winds from MM5/KMA model, which is being used for the operation system at the Korea Meteorological observation buoy data to verify the model results during Typhoon events. The correlation coefficients between the models and observation data reach up to about 95%, supporting that these models satisfactorily simulate the sea surface winds and wave heights even at the coastal regions. Based on these verification results, we have carried out numerical experiments about the wave modulation. When there exist an opposite strong current for the propagation direction of the waves or wind direction, wave height and length gets higher and shorter, and vice versa. It is proved that these modulations of wave parameters are well generated when wind speed is relatively week.

  • PDF

THE EFFECT OF CANAL OBTURATION ACCORDING TO THE DEPTH OF THE SYSTEM B PLUGGER TIP IN THE TYPE IV CANAL (제 IV 형 근관에서 System B Plugger tip의 깊이에 따른 근관 충전 효과)

  • Choi, Hee-Won;Kim, Soo-Mee;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.6
    • /
    • pp.518-525
    • /
    • 2008
  • The purpose of this study was to evaluate the effect of the apical sealing according to the depth of the System B Plugger tip when root canal was filled with gutta-percha and sealer by Continuous Wave of Condensation technique in the Type IV canal. 50 simulated resin blocks with J-shaped curvature canals were instrumented by ProTaper (Dentsply Maillefer, Ballagiues, Switzerland) Ni-Ti files using the crown-down technique. Type IV canals were made using a broken ProTaper F3 Ni-Ti file for making a ledge at 3mm short from the working length. And ProTaper F1 Ni-Ti file was used for perforating resin block. The prepared Type IV canals were randomly divided into three experimental groups of 15 each according to the depth of System B Plugger tip. All of experimental groups were obturated with Continuous Wave of Condensation technique. The length of gutta-percha and sealer in lingual of the Type IV canals was measured with a measuring digital calliper under magnifying glass (${\times}2.3$). The results are as follows : 1. In control group, there was no gutta-percha and sealer in lingual canal. 2. 3 mm group showed relatively more gutta-percha than 5mm or 7 mm group (p<0.05). 3. 7 mm group did not showed gutta-percha and relatively more void were observed than 3mm or 5 mm group. (p<0.05) In conclusion, within the limits of the results of this experiment, the 3 mm depth of System B Plugger tip was acceptable for obturating the Type IV canal.

Development of Broadband Electromagnetic Wave Absorber for X-band Sensors in Double-layered Type Using Carbon

  • Choi, Chang-Mook;Kim, Dong-Il;Li, Rui;Choi, Dong-Han
    • Journal of Navigation and Port Research
    • /
    • v.30 no.9
    • /
    • pp.763-766
    • /
    • 2006
  • In this paper, the EM wave absorbers were designed and fabricated for X -band sensors using Carbon of dielectric material with CPE. The complex relative permittivity of samples is calculated by using measurement results of S-parameter. We simulated the double-layered type EM wave absorber with broad bandwidth using the measured complex relative permittivity by changing the thickness and layer, which was fabricated based on the simulated design The fabricated EM wave absorber consists of 1 mm first layer sheet facing metal with Carbon composition ratio 70 vol. % and 1.5 mm second layer sheet with Carbon composition ratio 60 vol. %. The measured results showed a good agreement to the simulated ones. It is found toot the optimized absorption ability of double-layered type EM wave absorber with thickness of 2.5 mm is higher than 10 dB from 7.8 GHz to 13.3 GHz.

Development of Broad-Band Electromagnetic Wave Absorber for X-band Sensors in Double-layered Type Using Carbon

  • Choi, Chang-Mook;Kim, Dong-Il;Choi, Dong-Han;Li, Rui
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.297-300
    • /
    • 2006
  • In this paper, the EM wave absorbers were designed and fabricated for X-band sensors using Carbon of dielectric material with CPE. The complex relative permittivity of samples is calculated by the measured S-parameter data. We simulated the double-layered type EM wave absorber with broad bandwidth using the measured complex relative permittivity by changing the thickness and layer, which was fabricated based on the simulated design. The fabricated EM wave absorber consist of 1mm first layer sheet facing metal with Carbon composition ratio 70 vol% and 1.5 mm second layer sheet with Carbon composition ratio 60 vol%. The comparisons of simulated and measured results are good agreement. As a result, the optimized absorption ability of double-layered type EM wave absorber with thickness of 2.5 mm is higher than 10 dB from 7.8 GHz to 13.3 GHz.

  • PDF

A Study on the Modeling of Electromagnetic Wave Propagation for the Detection of a Delamination in Concrete Specimens (콘크리트 내의 공동탐사를 위한 전자기파 모델링)

  • 조윤범;임홍철
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.119-124
    • /
    • 2000
  • The radar method is becoming one of the major nondestructive testing (NDT) techniques for concrete structures. Numerical modeling of electromagnetic wave is needed to analyze radar measurement results and to study the influence of measurement parameters on the radar measurements. Finite difference-time domain (FD-TD) method is used to simulate electromagnetic wave propagation through concrete specimens. Three concrete specimens with a 25 mm delamination embedded at 25 mm, 50 mm, and 75mm depth are modeled in 3-dimension. Also, thickness change of delamination and permittivity change are modeled.

  • PDF

Effect of Transcutaneous High Frequency Wave on the Change of Tissue Temperature and Histology in Sprague-Dawley Rat (백서에서 경피적 고주파 자극에 따른 온도 변화 및 조직 변화)

  • Kim, Kyung Ah;Moon, Chang Won;Song, Da-Hyun;Kim, Sang Jun
    • Clinical Pain
    • /
    • v.15 no.2
    • /
    • pp.92-96
    • /
    • 2016
  • Objective: High frequency wave has been used in cancer treatment and cosmetic area but not in musculoskeletal pain yet. The purpose of this study is to evaluate temperature distribution according to depth and confirm safety of high frequency wave through animal study. Method: High frequency wave was applied to the posterior limb of 9 Sprague-Dawley rats for 20 minutes (experimental group) and no wave was used in the same number of rats for control group. Tissue temperature was measured from skin surface to 1 cm depth (surface, 1 mm, 5 mm, and 1 cm) for 5 seconds. Results: In the experimental group, temperature was elevated 3.2℃ at skin surface, 2.87℃ at 1 mm, 2.25℃ in 5 mm, and 1.74℃ in 1 cm depth. These were significantly different from those in the control group (p<0.001). There was no bulla or redness in the skin after high frequency wave stimulation and neither change of myocytes nor collagen degeneration was found in the tissue histology. There was no apoptosis in the skin surface and muscle layer in TUNEL assay. Conclusion: High frequency wave elevated tissue temperature from the skin to muscle layer without both histologic change and apoptosis.

A study on reflective spectrum between In-Ceram alumina core and IPS Empress 2 core (In-Ceram Alumina Core와 IPS Empress 2 core의 분광반사율 연구)

  • Park, Myung-Ja;Kim, Joo-Won
    • Journal of Technologic Dentistry
    • /
    • v.23 no.2
    • /
    • pp.189-202
    • /
    • 2002
  • A study on reflective spectrum between In-Ceram alumina plate(IAP) and IPS empress 2 plate were carried out in order to determine the difference of reflective spectrum rates between materials and between thicknesses of materials(0.8mm, 1.0mm, 1.2mm) by visible wave. The rates are measured by spectrophotometer(Top scan model TC-1800). And an analysis of ANOVA and paired sample t-test were carried out. The results are summarized as follows. 1. The reflective rates of IAP and IPS increased slowly as visible wave spectrum increased. 2. The difference of reflective rates of IAP between 0.8mm and 1.0mm is significant but a little(less than 1%). The differences of reflective rates of IAP between 0.8mm and l.2mm and between 1.0mm and l.2mm are significant(8%, 10% ). 3. The differences of reflective rates of IPS between 0.8mm and 1.0mm and between 0.8mm and 1.2mm and between 1.0mm and 1.2mm are significant(0.06 %, 0.01 %, 2 %). 4. The differences of reflective rates of 0.8mm, 1.0mm between IAP and IPS are significant but a little(less than 0.9%, 0.5%). The difference of reflective rates of l.2mm between IAP and IPS is significant and larger than the other thicknesses relatively(7 %).

  • PDF