• 제목/요약/키워드: mm long

검색결과 2,127건 처리시간 0.027초

Denta $Scan^R$을 이용한 즉시 임플랜트 시술시 최적의 식립 위치 대한 통계적 연구 (STATISTICAL STUDY ON OPTIMAL PLACEMENT OF IMMEDIATE DENIAL IMPLANTATION USING DENTA $SCAN^R$)

  • 신광호;이재봉;황병남
    • 대한치과보철학회지
    • /
    • 제38권4호
    • /
    • pp.552-560
    • /
    • 2000
  • Purpose : The purpose of this study was to determine proper position and angulation of an implant for immediate implantation. Materials and Method : From the years 1997 to 2000. 52 Denta $scan^R$ views, 22 upper and 32 lower jaw with an average age of 43 and 40 respectively, were investigated, which comprise intact upper and lower 6 anterior teeth and premolars. On the Denta $scan^R$, the optimal placement for the immediated implantation was simulated. The measuring methods included 1) Angulation difference between tooth long axis and alveolar bone process. 2) Angulation difference of long axis between tooth and installing fixture 3) Distance between center of tooth at cervical area and center of fixture. 4) Distance from root apex to the bone limit of vital structure. One sample t-test was used for statistical analysis. Result : The results were as follows. 1) At the maxillary central incisor and lateral incisor, angulation difference of long axis between tooth and installing fixture was respectively 0.5 and 3.2 degrees with the fixture center's palatally positioned 2mm apart from tooth center. 2) At the lower anterior 6 teeth, that was about $-2.8^{\circ}\;to\;-4.6^{\circ}$ with the fixture center's lingually positioned 1mm apart from tooth center. 3) At the maxillary canine and premolar, that was respectively $11.8^{\circ}\;and \;7.2^{\circ}$ with the fixture center palatally positioned $2\sim2.4mm$ apart from tooth center. 4) At the lower premolar area, that was about $0^{\circ}\;to\;2^{\circ}$ with the fixture center's lingually positioned $0.5{\sim}1mm$ apart from tooth center. 5) Distance from root apex to the bone limit of vital structure, at the maxillary anterior and premolars. was the range of 10 to 12mm, and at the mandibular anterior teeth and the 1st premolar, that was the range of 18 to 20mm. Conclusion : The proper implant position of maxillary anterior and premolar teeth is as paralleled as or more buccally angulated than long axis of tooth with the fixture center's palatally positioned. In mandiblular anterior region, long axis of implants is lingully angulated compared with long axis of tooth and in premolar, almost parelleled with long axis of tooth and alveolar process.

  • PDF

영상처리를 이용한 작물의 모종시기 결정 (Determination of Transferring Period of Several Plants using Image Processing)

  • 민병로;김웅;김동우;이대원
    • 생물환경조절학회지
    • /
    • 제13권3호
    • /
    • pp.178-184
    • /
    • 2004
  • 본 연구는 영상 처리를 이용하여 채소의 모종 시기를 자동으로 파악할 수 있는 시스템을 개발하기 위한 것이다 즉 작물의 높이, 장변 및 단변을 영상처리를 이용해 자동으로 측정하고자 하는 시스템을 개발하고자 한 것이다. 각 작물 당 20개씩의 실험체를 두어반복 측정한 결과, 들깨의 경우 높이는 평균 오차 5.0mm로 평균 실측 길이 대비 1.7% 오차율, 장변은 평균 오차 4.7mm, 오차율 3.9%, 단변은 평균 오차 5.5 mm, 오차율 6.9%로 나타났다. 도라지의 경우 높이는 평균 오차 2.4 mm, 오차율 8.1%, 장변은 평균 오차 3.4 mm, 오차율 7.2%, 단변은 평균 오차 4.0 mm, 오차율 10.4%로 나타났다. 상추의 높이는 평균 오차 4.0 mm, 오차율 9.1%, 장변은 평균 오차 3.4 mm, 오차율 7.2%, 단변은 평균 오차 3.6mm, 오차율 9.4%로 나타났다. 따라서 현장 환경에 맞게 좀 더 개선된다면 사람의 시각을 이용한 작물의 생장상태 판별보다 더 정확하다고 판단된다.

다양한 섬유재료를 이용한 화선지의 제조와 그 특성 (Manufacture of Oriental Painting Paper (Hwaseonji) Using Various Kinds of Plant Fibers)

  • 문성필;최영재;강석근
    • 펄프종이기술
    • /
    • 제35권3호
    • /
    • pp.79-84
    • /
    • 2003
  • Oriental painting paper (Hwaseonji) was prepared from various kinds of plant fibers and its physical properties were investigated. The fibers used were classified into three different length of fibers; long fiber (<1.8 mm), medium fiber (1.4-1.8 mm) and short fiber (>1.4 mm). The fibers were mixed in the ratio of 15% long fiber, 25% medium fiber and 60% short fiber. The Hwaseonji prepared from mixing of the bamboo or rice straw pulp as a short fiber with the long and medium fibers showed excellent physical properties with a high smoothness and uniformity of Chinese ink blot. Mixing with LBKP as a short fiber was resulted in low physical properties, smoothness and wide ink blot. The properties of Hwaseonji, such as ink absorption, roughness and smoothness, may be predicted from the correlation of density with Chinese ink blot and smoothness.

Dependencies of Ultrasonic Velocities on the Wall Thickness in Polyvinyl Chloride Cortical Bone Mimics

  • Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권3E호
    • /
    • pp.140-145
    • /
    • 2010
  • In the present study, tubular polyvinyl chloride (PVC) cortical bone mimics that simulate the cortical shell of long bones were used to validate the axial transmission technique for assessing the cortical thickness by measuring the ultrasonic velocities along the cortical shell of long bones. The ultrasonic velocities in the 9 PVC cortical bone mimics with wall thicknesses from 4.0 to 16.1 mm and inner diameters from 40 to 300 mm were measured as a function of the thickness by using a pair of custom-made transducers with a diameter of 12.7 mm and a center frequency of 200 kHz. In order to clarify the measured behavior, they were also compared with the predictions from a theory of guided waves in thin plates. This phantom study using the PVC cortical bone mimics provides useful insight into the dependencies of ultrasonic velocities on the cortical thickness in human long bones.

고강도 알루미늄에서의 균열닫힘이 미소 피로균열의 전파거동에 미치는 영향 (Crack Closure Effects on Small Fatigue Crack Growth Behavior in High Strength Aluminum)

  • 이현우
    • 한국정밀공학회지
    • /
    • 제7권4호
    • /
    • pp.55-64
    • /
    • 1990
  • The fatigue crack growth behavior of physically-short cracks(0.2${\Delta}K$ with $da/dN<1{\times}10^{-7}m/cycle$. The transition crack lengths where similtude with ${\Delta}K$ existed was between 1 and 2mm. The effective stress intensity factor range based on COD measurements gave better correlation between the physically-short and long cracks. Thus it can be considered that the crack closure effect is one of the main factors which causes the differences between these two cracks.

  • PDF

Passive Temperature Compensation Package for Optical Long Period Fiber Gratings

  • Lee, Sang-Mae;Gu, Xijia
    • Journal of the Optical Society of Korea
    • /
    • 제3권2호
    • /
    • pp.74-79
    • /
    • 1999
  • We present a simple design rule for a passive temperature-compensating optical package. We also present experimentally that a package fabricated by using the design rule compensates the temperature dependence of the resonant wavelength of an optical long period fiber grating by varying the strain inside the fiber, The package fabricated in this work consists of two pieced of brass tube, 10 mm long, and a piece of nylon rod, 45.4 mm long. It is shown that the package can compensate the temperature-induce wavelength shifts of the long period grating to a range of 6.8 pm/$^{\circ}C$, compared with 0..48 nm/$^{\circ}C$ for an uncompensated grating. The reduced strength of the fiber caused by exposure to ultraviolet limits the performance of the package to the range operating temperature form -3 $^{\circ}C$ to 7$0^{\circ}C$.

사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(IV) - 압축정재하시험 및 양방향재하시험 자료 분석을 통한 매입 PHC말뚝의 장기허용압축하중의 실증 성능 검증 - (Study(IV) on the Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - Field Verification of Long-term Allowable Compressive Load of PHC Piles by Analyzing Pile Load Test Results -)

  • 이원제;김채민;윤도균;최용규
    • 한국지반공학회논문집
    • /
    • 제35권9호
    • /
    • pp.29-36
    • /
    • 2019
  • 직경 500mm 및 직경 600mm PHC말뚝 A종의 파괴 압축하중($P_n$)은 각각 7.7MN 및 10.6MN으로 계산할 수 있었다. 직경 500mm 및 직경 600mm 매입 PHC말뚝 A종에 대한 압축정재하시험 시 말뚝 두부에 재하된 최대 압축하중은 6.9MN 및 8.8MN으로 측정할 수 있었으며 따라서 이 측정하중은 각각 $P_n$의 90% 및 83% 수준이었다. 직경 500mm 및 직경 600mm PHC말뚝 A종의 장기허용압축하중($P_a$)은 각각 1.7MN 및 2.3MN이었다. 모든 사례 매입 PHC말뚝의 양방향재하시험 자료로부터 계산된 지반의 허용지지력은 국내 현행 설계에서 사용하고 있는 극한지지력 산정공식으로 계산한 지반의 허용지지력보다 높은 수준으로 계산되었다. 따라서 매입 PHC말뚝의 설계에서 사용하는 극한지지력 산정공식은 매입 PHC말뚝의 실제 지지력 거동을 모사할 수 있도록 개선하여야 할 것으로 판단되었다.

A novel classification of anterior alveolar arch forms and alveolar bone thickness: A cone-beam computed tomography study

  • Bulyalert, Atcharee;Pimkhaokham, Atiphan
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose: This study classified alveolar arch forms and evaluated differences in alveolar bone thickness among arch forms in the anterior esthetic region using cone-beam computed tomography (CBCT) images. Materials and Methods: Axial views of 113 CBCT images were assessed at the level of 3 mm below the cementoenamel junction (CEJ) of the right and left canines. The root center points of teeth in the anterior esthetic region were used as reference points. Arch forms were classified according to their transverse dimensions and the intercanine width-to-depth ratio. The buccolingual alveolar bone thickness of each tooth was measured at 3 mm below the CEJ and at the mid-root level. Differences in the mean thicknesses among arch forms were analyzed. Results: Anterior maxillary arches could be classified as long narrow, short medium, long medium, and long wide arches. Significant differences in buccolingual alveolar bone thickness among the arch groups were found at both levels. The long wide arches presented the greatest bone thickness, followed by the long medium arches, while the long narrow and short medium arches were the thinnest. Conclusion: Arch forms were classified as long narrow, short medium, long medium, and long wide. The buccolingual alveolar bone thickness exhibited significant differences among the arch forms.

Early Life History of Rhodeus Fish (R. uyekii and R. ocellatus) in the Nakdong River Water System

  • Park, Jae-Min;Han, Kyeong-Ho
    • 한국발생생물학회지:발생과생식
    • /
    • 제22권1호
    • /
    • pp.39-53
    • /
    • 2018
  • The purpose of this study is to investigate the early life history of the Rhodeus fish, Rhodeus uyekii and R. ocellatus, in the Nakdong River to use as the preliminary data for the systematic study. The embryos used in the study were fertilized eggs (embryo) and larvae after artificial fertilization. The long diameter of the eggs of the R. uyekii was 3.39-3.97 mm (average $3.68{\pm}0.41mm$, n=30) and the short diameter was 1.36-1.55 mm (average $1.45{\pm}0.13mm$, n=30). The long diameter of the eggs of the R. ocellatus was 2.53-2.71 mm (average $2.62{\pm}0.12mm$, n=30) and the short diameter was 1.47-1.60 mm (average $1.53{\pm}0.09mm$, n=30). Hatching time was 48 hours for the R. uyekii and 50 hours for the R. ocellatus given that the average water temperature was $21.5^{\circ}C$. The hatched larvae were 4.95-5.00 mm (average $4.98{\pm}0.04mm$, n=5) for the R. uyekii and the total length was 3.66-3.69 mm (average $3.67{\pm}0.02mm$, n=5) for the R. ocellatus. R. uyekii was found to be 15.5-15.8 mm at total length (average $15.6{\pm}0.21mm$, n=5) on the 56 days after hatching with the number of dorsal fins being ⅲ-9, anal fins ⅲ-10, ventral fins ⅲ-5. The R. ocellatus was found to be 15.8-16.0 mm (average $15.9{\pm}0.14mm$, n=5) at total length on the 58 days with the number of dorsal fins being ⅲ-11, anal fins ⅲ-12 and ventral fins ⅲ-5 where the number of all fin stalks reached maximum.

교점용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교 (Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants)

  • 윤순동;임성훈
    • 대한치과교정학회지
    • /
    • 제39권2호
    • /
    • pp.95-104
    • /
    • 2009
  • 본 연구는 self-tapping screw의 특징적 구조인 cutting flute의 길이 및 형태 변화에 따른 미니 임플랜트의 식립 및 제거 토크를 비교해보기 위해 시행되었다. 외경, 내경, 길이 및 pitch 등 다른 조건이 모두 동일하고 cutting flute의 형태만 다른 세 종류의 미니 임플랜트를 사용하였다(A군; 2.6 mm 길이의 flute가 형성된 그룹, B군; 3.9 mm의 길이이면서 직선형의 flute를 갖는 그룹, C군; 3.9 mm의 길이이면서 나선형의 flute를 갖는 그룹). 골밀도를 균일하게 하기 위해 실험용 인공골(Sawbones Inc., USA)을 사용하였으며, 수직력 및 회전속도를 일정하게 하기 위해 구동식 토크시험기를 이용하였다. 그 결과 다음과 같은 결론을 얻었다. 총 삽입 시간은 2 mm 두께의 피질골 시편에서는 세 군간에 차이를 보이지 않으나, 4 mm 두께의 피질골 시편에서는 C군 > B군 > A군 순으로 짧은 삽입 시간을 보였다. 최대 삽입 토크는 2 mm 두께의 시편에서는 A군이 다른 두 군에 비해 높은 값을 보이나, 4 mm 두께의 피질골 시편에서는 C군 > A군 > B군 순으로 높은 값을 보였다. 최대 제거 토크는 2 mm 두께의 피질골 시편에서는 세 군 사이에 차이가 없으나, 4 mm 두께의 피질골 시편에서는 C군이 다른 두 군에 비해 높은 값을 보여주었다. 이상의 결과로 보아 피질골이 두꺼운 부위에 미니 임플랜트를 식립할 경우 cutting flute의 길이 및 형태 또한 고려하여 미니 임플랜트를 선택하는 것이 바람직하다.